DOWNLOAD Panasonic KX-TG2511UAM / KX-TG2511UAN / KX-TG2511UAS / KX-TG2511UAT / KX-TG2512UAM / KX-TG2512UAT / KX-TGA250RUM / KX-TGA250RUN / KX-TGA250RUS / KX-TGA250RUT (serv.man5) Service Manual ↓ Size: 3.69 MB | Pages: 83 in PDF or view online for FREE

Model
KX-TG2511UAM KX-TG2511UAN KX-TG2511UAS KX-TG2511UAT KX-TG2512UAM KX-TG2512UAT KX-TGA250RUM KX-TGA250RUN KX-TGA250RUS KX-TGA250RUT (serv.man5)
Pages
83
Size
3.69 MB
Type
PDF
Document
Service Manual / Supplement
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg2511uam-kx-tg2511uan-kx-tg2511uas-kx-tg2511ua.pdf
Date

Panasonic KX-TG2511UAM / KX-TG2511UAN / KX-TG2511UAS / KX-TG2511UAT / KX-TG2512UAM / KX-TG2512UAT / KX-TGA250RUM / KX-TGA250RUN / KX-TGA250RUS / KX-TGA250RUT (serv.man5) Service Manual / Supplement ▷ View online

57
13.7. Things to Do after Replacing IC or X'tal
If repairing or replacing BBIC (FLASH type), EEPROM and X'tal, it is necessary to download the required data such as Program-
ming data or adjustment data, etc in memory.
The set doesn't operate if it is not executed.
13.7.1.
How to download the data
13.7.1.1. Base Unit
[Changed from original section “11.7.1.1. Base Unit”]
First, operate the PC setting according to The Setting Method of JIG (Base Unit)(P.50).
Then download the appropriate data according to the following procedures.
Note:
(*1) W: country code, XXX: revision number
“XXX” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting Method of
JIG (Base Unit)
 (P.50).
(*2) Refer to Check Point (Base Unit) (P.40)
Items
How to download/Required adjustment
EEPROM (IC611)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “55” to download 
the data.
2) Default batch file: Execute the command “default.bat”.
3) Country version batch file: Execute the command 
“TG2511VE_W_RevXXX.bat” (*1)
4) Clock adjustment: Refer to Check Point (E). (*2)
X'tal (X501)
System clock
Clock  adjustment  data is in EEPROM, adjust the data again
after replacing it.
1) Apply 5.5V between DCP ad DCM with DC power.
2) Input Command "sendchar sfr", then you can confirm the cur-
rent value.
3) Check X'tal Frequency.(13.824 MHz ± 100 Hz).
4) If the frequency is not 13.824 MHz ± 100 Hz, adjust the fre-
quency of CKM executing the command "sendchar sfr xx xx
(where xx is the value)" so that the reding of the frequency
counter is 13.824000 MHz ± 7 Hz. 
58
13.7.1.2. Handset
[Changed from original section “11.7.1.2. Handset”]
First, operate the PC setting according to The Setting Method of JIG (Handset)(P.54).
Then download the appropriate data according to the following procedures.
Note:
(*3)  W: country code, XXX: revision number
“XXX” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting Method of
JIG (Handset)
 (P.54)
.
(*4) Refer to Check Point (Handset) (P.42)
Items
How to download/Required adjustment
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “00” to download 
the data.
2) Default batch file: Execute the command “default.bat”.
3) Default batch file (remaining): Execute the command 
“TGA255RU_DEF_RevXXX.bat”. (*3)
4) Country version batch file: Execute the command 
“TGA255RU_W_RevXXX.bat”. (*3)
5) Clock adjustment: Refer to Check Point (H). (*4)
6) 1.8 V setting and battery low detection: Refer to Check Point 
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock  adjustment  data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (C). (*4)
59
13.8. RF Specification
13.8.1.
Base Unit
*: Refer to Check Point (Base Unit) (P.40)
13.8.2.
Handset
**: Refer to Check Point (Handset) (P.42)
Item
Value
Refer to -. *
TX Power
19 ~ 24 dBm
Check Point (Base Unit) (H)
Modulation
-350 ± 50/+350 ± 50 kHz/div
Check Point (Base Unit) (I)
Frequency Offset
±20 kHz
Check Point (Base Unit) (J)
RX Sensitivity
< 1000 ppm
Check Point (Base Unit) (K)
Power RAMP
Power RAMP is matching
Check Point (Base Unit) (L)
Item
Value
Refer to -. **
TX Power
19 ~ 24 dBm
Check Point (Handset) (I)
Modulation
-350 ± 50/+350 ± 50 kHz/div 
Check Point (Handset) (J)
Frequency Offset
±20 kHz
Check Point (Handset) (K)
RX Sensitivity
< 1000 ppm
Check Point (Handset) (L)
Power RAMP
Power RAMP is matching
Check Point (Handset) (M)
60
13.9. How to Check the Handset Speaker or Receiver
1. Prepare the digital voltmeter, and set the selector knob to ohm meter.
2. Put the probes at the speaker terminals as shown below.
13.10. Frequency Table (MHz)
Note:
Channel No. 10: In the Test Mode on Base Unit and Handset.
BASE UNIT
HANDSET
Channel No
Transmit Frequency
Receive Frequency
Transmit Frequency
Receive Frequency
1
1897.344 1897.344 1897.344 1897.344 
2
1895.616 1895.616 1895.616 1895.616 
3
1893.888 1893.888 1893.888 1893.888 
4
1892.160 1892.160 1892.160 1892.160 
5
1890.432 1890.432 1890.432 1890.432 
6
1888.704 1888.704 1888.704 1888.704 
7
1886.976 1886.976 1886.976 1886.976 
8
1885.248
1885.248
1885.248
1885.248
9
1883.520 1883.520 1883.520 1883.520 
10
1881.792 1881.792 1881.792 1881.792 
Handset speaker (receiver)
Digital Voltmeter
Is the value between
(+) terminal and (–) terminal about 34 
Ω?
RECEIVER:
Is the value between
(+) terminal and (–) terminal about 8 
Ω?
NG
NO
OK
YES
Replace the speaker 
(receiver).
SPEAKER:
Page of 83
Display

Click on the first or last page to see other KX-TG2511UAM / KX-TG2511UAN / KX-TG2511UAS / KX-TG2511UAT / KX-TG2512UAM / KX-TG2512UAT / KX-TGA250RUM / KX-TGA250RUN / KX-TGA250RUS / KX-TGA250RUT (serv.man5) service manuals if exist.