PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg1711uab-kx-tg1711uaj-kx-tg1711uaw-kx-tga171ru.pdf
Date

Panasonic KX-TG1711UAB / KX-TG1711UAJ / KX-TG1711UAW / KX-TGA171RUB / KX-TGA171RUJ / KX-TGA171RUW Service Manual ▷ View online

9
KX-TG1711UAB/KX-TG1711UAJ/KX-TG1711UAW/KX-TGA171RUB/KX-TGA171RUJ/KX-TGA171RUW
4.2.3.
Telephone Line Interface
<Function>
• Bell signal detection
• Clip signal detection
• ON/OFF hook circuit
• Audio circuits
Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection:
In the standby mode, Q3 is open to cut the DC loop current and decrease the ring load.
When ring voltage appears at the L1T and L1R leads (when the telephone rings), the signal is transferred as follows; 
• A 
→ C26 → R33 → R50, C70 → R16, R30 → R200 → LINEN [BELL & CLIP]
• B 
→ C27 → R34 → R51, C71 → R19, R31 → R201 → LINEP [BELL & CLIP]
ON/OFF hook circuit:
In the standby mode, Q3 is open, and connected as to cut the DC loop current and to cut the voice signal. The unit is consequently
in an off-hook condition
When IC3 detects a ring signal or press the TALK Key onto the handset, Q2 turns on and then Q3 turns on, thus providing an off-
hook condition
 (active DC current flow through the circuit) and the following signal flow is for the loop current.
• A 
→ D2 → Q3 → Q1 → R9 → R10 → D2→ B [OFF HOOK]
Audio circuits:
Refer to Signal Route (P.12). 
4.2.4.
Transmitter/Receiver
Base Unit and Handset mainly consist of RF Module and DECT BBIC. 
Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency.
Signal Path:
*Refer to Signal Route (P.12).
4.2.4.1.
Transmitter Block
The voice signal input from the TEL LINE interface goes to DECT BBIC (IC3) as shown in Block Diagram (Base Unit) (P.7)
The voice signal passes through the analog part of IC3 where it is amplified and converted to a digital audio stream signal. The
burst switch controller processes this stream performing encryption and scrambling, adding the various other fields to produce
the GAP (Generic Access Profile) standard DECT frame, assigning to a time slot and channel etc.
In IC3, the carrier frequency is changing, and frequency modulated RF signal is generated and amplified, and radiated from
antenna. Handset detects the voice signal or data signal in the circuit same as the following explanation of Receiver Block.
4.2.4.2.
Receiver Block
The signal of 1.9 GHz band (1.881792 GHz ~ 1.897344 GHz) which is input from antenna is input to IC3 as shown in Block
Diagram (Base Unit)
 (P.7).
In IC3, the signal of 1.9 GHz band is demodulated, and goes to IC2 as GAP (Generic Access Profile) standard DECT frames. It
passes through the decoding section burst switch controller where it separates out the frame information and performs de-
encryption and de-scrambling as required. It then goes to the DSP section where it is turned back into analog audio. This is
amplified by the analog front end, and goes to the TEL LINE Interface.
4.2.5.
Pulse Dialling
During pulse dialling the hookswitch (Q3, Q4) is used to generate the pulses using the HOOK control signal, which is set high
during pulses. To force the line impedance low during the “pause” intervals between dial pulses, the PULSE_DIAL signal turns
on Q2.
10
KX-TG1711UAB/KX-TG1711UAJ/KX-TG1711UAW/KX-TGA171RUB/KX-TGA171RUJ/KX-TGA171RUW
4.3.
Block Diagram (Handset)
E a r p i e s e 
( S p e a k e r ) 
A n a l o g 
F r o n t 
E n d 
D S P 
R F 
C P U 
X T A L 
2 0 . 7 3 6 M H z 
X101
E E P R O M 
( I C 1 0 2 ) 
B A T T E R Y 
C O S I C 
C h a r g e + 
C h a r g e - 
R e g u l a t o r 
3 . 3 V 
5
4
45
44
35
36
C h a r g e 
c i r c u i t 
S C L K 
D A T A 
48
47
M I C 
K E Y P A D 
O N  S W I T C H 
R I N G E R 
3 . 3 V 
37
R102
C H A R G E 
C H A R G E 
L C D 
3 . 3 V 
V D D B A T 
V D D D C D C 
Q 1 0 3
38
1
2 . 4 V 
2 . 4 V 
Q101/102
2 . 4 V 
SDRV
M A D 4 P 
32
IC103
IC101
KX-TGA171 BLOCK DIAGRAM (HANDSET)
BZ2
R102
Q105
53
54
Q104
11
KX-TG1711UAB/KX-TG1711UAJ/KX-TG1711UAW/KX-TGA171RUB/KX-TGA171RUJ/KX-TGA171RUW
4.4.
Circuit Operation (Handset)
4.4.1.
Outline
Handset consists of the following ICs as shown in Block Diagram (Handset) (P.10).
• DECT BBIC (Base Band IC): IC103
- All data signals (forming/analyzing ACK or CMD signal)
- All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD)
- PLL Oscillator
- Detector
- Compress/Expander
- Amplifier for transmission and reception
• EEPROM: IC102
- Temporary operating parameters
4.4.2.
Power Supply Circuit/Reset Circuit
Circuit Operation:
When power on the Handset, the voltage is as follows;
The Reset signal generates R121, C186 and  2.6V.
4.4.3.
Charge Circuit
Circuit Operation:
When charging the handset on the Base Unit, the charge current is as follows;
DC+ 
→ F1 → R39 → CHARGE+ (Base) → CHARGE+ (Handset) → Q101 → L104 → BATTERY+... Battery... 
BATTERY- 
→ R102 → GND → CHARGE- (Handset)→ CHARGE- (Base) → GND → DC- (GND)
In this way, the BBIC on Handset detects the fact that the battery is charged.
The charge current is controlled by switching Q101 of Handset.
Refer to Fig.101 in Power Supply Circuit (P.8).
4.4.4.
Battery Low/Power Down Detector
Circuit Operation:
“Battery Low” and “Power Down” are detected by BBIC which check the voltage from battery.
The detected voltage is as follows;
• Battery Low
Battery voltage: V (Batt) < 2.20V
The BBIC detects this level and “
” is displayed on LCD and “battery alarm” starts ringing.
• Power Down
Battery voltage: V (Batt) < 2.05V
The BBIC detects this level and power down.
B A T T E R Y   ( 2 . 2   V      2 . 6 V )           D 1 0 7          IC103 - V D D B A T           I C 1 0 3 - S D R V           R 1 0 7  
L 1 0 3          I C 1 0 1          3 . 3 V 
~
12
KX-TG1711UAB/KX-TG1711UAJ/KX-TG1711UAW/KX-TGA171RUB/KX-TGA171RUJ/KX-TGA171RUW
4.5.
Signal Route
(BASE UNIT)
IC3 - H01P, H01N - R2 - C5 - Q1 - Q3 - D2       A
SIGNAL ROUTE
ROUTE
IN
OUT
SIGNAL
DTMF TONE
TEL OUT 
(to Tel Line)
CDL TX
(to Tel Line)
CDL RX
(from Tel Line)
(BASE UNIT)
from HANDSET        ANT1 - C41          D6 - D801 - C820 - IC3 - RXI, RXIX - IC3 - H01P, H01N -  
B
 ANT2 -  C39
R2 - C5 - Q1 - Q3 - D2         A
B
B
(BASE UNIT)
A        D2 - Q3 - R12 - C15 - R14 - IC3 - LINEA - IC3 - POS, POX - C826 - D801 - D6
Caller ID 
(from Tel Line)
(BASE UNIT)
A - C26 - R33 - R50 - R200 - IC3 - LINEN
B - C27 - R34 - R51 - R201 - IC3 - LINEP
              C39     -      ANT1 to HANDSET
C41      -     ANT2 to HANDSET
IC103 - H01N - SPEAKER (-)
(HANDSET)
from BASE UNIT - ANTENNA - C149 - D803 - C820 - IC3 - RXI, RXIX       IC103 - H01P -  SPEAKER (+)
(HANDSET)
MIC        C105 - IC103 - MICP                      ANT to BASE UNIT
R105 - C106 -  IC103  - MICN
DTMF TONE
TEL IN 
(from Tel Line)
B
(BASE UNIT)
A        D2 - Q3 - R12 - C15
Page of 60