36
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
11.2. Adjustment Standard (Base Unit)
When connecting the simulator equipment for checking, please refer to below.
11.2.1. Bottom View
Note:
(A) - (O) is referred to Check Point (Base Unit) (P.24)
YLW
BLK
TEL
BRN
RED
GRY
DC
PUR
TP3
L1T
L1R
DCP
LINE_DC
DCM
P1.0
VDD
Charge
Charge+
RXD
TXD
GND
DC_IN
TP4
A
RXD
TXD
GND
L1R
L1T
DTMF
Tester
Call - ID
Simulator
BELL
Simulator
LOOP
Simulator
AF
OSC
AF VOLT
METER
OSC
OSC
600
150
SP
Serial
JIG
PC
AF VOLT
METER
Dummy Handset
MIC
AF
OSC
6.3 V 47   F 
DC_IN
GND
DC POWER
DC 6.5V
GND
ANT
DECT Tester
CTS60
Digital
Volt Meter
12
2W
CHARGE-
CHARGE+
Digital
Volt Meter
LINE_DC
GND
Frequency
Counter
CLK
GND
Digital
Volt Meter
VDD
GND
37
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
11.3. Adjustment Standard (Charger Unit)
When connecting the simulator equipment for checking, please refer to below.
11.3.1. Bottom View
Note:
(A) is referred to Check Point (Charger Unit) (P.26)
A
PNLB1922Z
3.0A
F1
PbF
-IG
Charge-
Charge+
12    /2 W
Digital
Volt Meter
DC POWER
DC 5.5 V
(GND)
38
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
11.4. The Setting Method of JIG (Handset)
11.4.1. Preparation
11.4.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: it must be precise to be able to measure 1Hz (precision; ± 4ppm).
Hewlett Packard, 53131A is recommended.
• DC power: it must be able to output at least 1A current under 2.4V for Handset.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.4.1.2. JIG and PC
• Serial JIG
PQZZT1CD300E*
• PC which runs in DOS mode.
• Batch file CD-ROM for setting: PNZZTG1611RU
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.4.2. PC Setting
11.4.2.1. Connections
 Connect the DC Power or Battery to BATTERY(+) and BATTERY(-) (Handset).
 Serial JIG to the Serial Port of PC.
 Connect the Clip cable GND.
 Connect the Clip cable TXD and RXD.
Note:
*: Com port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New  value  (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
GND (black)
3
To Serial Port
(com port 1*)
PC
(yellow)
4
TXD
4
RXD (red)
Handset P. C. board
GND
TXD
RXD
DC Power
or Battery
BATTERY
1
BATTERY
-
+
VBAT
2
39
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
11.4.2.2. Batch file Setting
Note:
• “*****” varies depending on the country.
11.4.2.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeep
Read the data of EEPROM
Type “rdeep 00 00 10”, and the data from address “00 00” to “10” is read
out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E 98” is written.
setfreq
adjust Frequency of RFIC
Type “setfreq nn nn”.
Getchk
Read checksum
Type “getchk”.
wrteep
write eeprom
Type “wrteep 01 23 45”. “01 23” is address and “45” is data to be written.
1.
 Insert the Batch file CD-ROM into CD-ROM drive and 
   copy PNZZTG***** folder to your PC (example: D drive). 
2.
 Open a window of MS-DOS mode.
3.
 At the DOS prompt, type "D:" (for example) to select the
    drive, then press the Enter key.
  
4.
 Type "CD 
PNZZTG*****", then press the Enter key.
5.
 Type "CTE open com X", then press the Enter key 
(X: COM port number used for the serial connection on your PC).
6.
 Type "READID", then press the Enter key.  
   
䊶If any error messages appear, change the port number or 
  
䇭check the cable connection.
   
䊶If any value appear, go to next step.
7.
 Type "DOSKEY", then press the Enter key.
<Example: correct setting>
C: 
>Documents and Settings>D: 
D: 
>>CD >PNZZTG*****
D: 
>PNZZTG***** >CTE open com X
D: 
>PNZZTG*****>READID
00 52 4F A8 A8
D: 
>PNZZTG*****>DOSKEY
D: 
>PNZZTG*****>
<Example: incorrect setting>
C: 
>Documents and Settings>D: 
D: 
>>CD >PNZZTG*****
D: 
>PNZZTG***** >CTE open com X 
D: 
>PNZZTG*****>READID
ReadID
ReadIPUI Error: read access failed
D: 
>PNZZTG*****>
<Example for Windows>
On your computer, click [Start], select Programs 
(All Programs for Windows XP/Windows Server 2003), 
then click 
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt
(for Windows 2000/Windows XP/Windows Server 2003)
Page of 65