9.2.2.
Check Point (Charger Unit)
Note:
After the measuring, suck up the solder of TP.
The connection of adjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.37).
The connection of adjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.37).
(N)* Audio Check
-
1. Link with Handset which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 50mA.
3. Input -45dBm(600
2. Set line voltage to 48V and line current to 50mA.
3. Input -45dBm(600
Ω)/1kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -5.5 ± 3dBm and that the distortion level is < 5% at TEL
Line (600
Ω Load).
5. Input -20dBm(600
Ω)/1kHz to Line I/F. Measure the level at Receiver of
Handset and distortion level (*Receive volume set to third position from
minimum).
minimum).
6. Confirm that the level is -23.5 ± 3dBm and that the distortion level is < 5% at
Receiver (150
Ω Load).
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(A) Charging Check
-
1. Connect Charge Contact 10
Ω/2W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 2.8V ± 0.3V.
R1, F1
Items
Adjustment
Point
Procedure
Check or
Replace Parts
27
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
9.3.
Troubleshooting by Symptom (Handset)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Handset) (P.27)
level in detail.
(*2) Refer to Check Point (Handset) (P.27)
9.3.1.
Check Point (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*: PC Setting (P.38) is required beforehand.
The connections of simulator equipments are as shown in Adjustment Standard (Handset) (P.40).
*: PC Setting (P.38) is required beforehand.
The connections of simulator equipments are as shown in Adjustment Standard (Handset) (P.40).
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(A) Battery Supply
Confirmation
-
1. Confirm that the consumption current is < 200mA, that is, there is no short
circuit.
C143, R102,
L104
C140, L103,
IC101
C141, R201,
C102, C135,
C120, C131
C803, C825,
C110, C802,
C804, C148,
D107, C109,
R121, C186
L104
C140, L103,
IC101
C141, R201,
C102, C135,
C120, C131
C803, C825,
C110, C802,
C804, C148,
D107, C109,
R121, C186
(B) VDDDCDC2 Supply
Confirmation
-
1. Confirm that the voltage between VDDDCDC2 and GND is 3.3V ± 0.3V.
IC103, C140,
L103, R107,
IC101, C141,
R201, C102,
C135, C120
L103, R107,
IC101, C141,
R201, C102,
C135, C120
(C)* BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC103, X101,
C122, C123,
C127
C122, C123,
C127
(D) Charge Control Check &
Charge Current Monitor
Check
Check
-
1. Apply 6V between TP5(+) and TP6(-) with current limit of PSU to 250mA.
2. Confirm that the charge current is ON/OFF.
3. SW to decrease current limit of PSU to 75mA.
4. Confirm that the charge current is stable.
2. Confirm that the charge current is ON/OFF.
3. SW to decrease current limit of PSU to 75mA.
4. Confirm that the charge current is stable.
C101, C160,
R101, C161,
Q101, Q102,
C142, R108,
IC103
R101, C161,
Q101, Q102,
C142, R108,
IC103
(E)* Charge Detection (OFF)
Check
-
1. Stop supplying 6V to TP5(+) and TP6(-).
2. Execute the command “charge”.
3. Confirm that the returned value is 00 (hex).
2. Execute the command “charge”.
3. Confirm that the returned value is 00 (hex).
C101, C160,
R101, C161,
Q101, Q102,
C142, R108,
IC103
R101, C161,
Q101, Q102,
C142, R108,
IC103
You have DECT Tester.
(Model Number : CMD60)
Check item (A)-(C), (F)-(G).
Check item (A)-(C), (F)-(G).
Check item (A)-(C), (H).
Check item (A)-(C), (H)-(K), (M).
-
Check item (I), (L).
Check item (A)-(C), (H).
Check item (O).
Check item (A)-(C), (H)-(N).
Check item (O).
Remedy (*2)
Symptom
You don't have DECT Tester.
Battery strength is not indicated correctly by Battery icon.
You cannot hear the caller's voice.
You cannot use handset a little away from base unit
even if the handset is within range of the base unit.
even if the handset is within range of the base unit.
Does not link between base unit and handset.
The Audio level is high or low.
ex.)
checksum value
program number
011B
DCN2EA
28
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
(F)* Battery Monitor Check &
Adjustment (Important)
-
1. Apply 2.3V ± 0.005V between BATTERY (+) and BATTERY (-) with DC power.
2. Execute the command “deactmac” to stabilize the value.
3. Then, execute the command “readbatt”. The returned value is XX.
4. Confirm that XX is between 98 and A7.
2. Execute the command “deactmac” to stabilize the value.
3. Then, execute the command “readbatt”. The returned value is XX.
4. Confirm that XX is between 98 and A7.
98 < XX < A7 (Hex)
(If XX is out of range, change BBIC)
(If XX is out of range, change BBIC)
IC103, D107,
C148, C109
C148, C109
(G) Battery Low
Confirmation (Important)
-
1. Apply 2.40V between BATTERY (+) and BATTERY (-).
2. Confirm that there is no Speaker sound (Battery low alarm).
3. Apply 2.2V between BATTERY(+) and BATTERY(-).
4. Confirm that there is Speaker sound (Battery low alarm).
2. Confirm that there is no Speaker sound (Battery low alarm).
3. Apply 2.2V between BATTERY(+) and BATTERY(-).
4. Confirm that there is Speaker sound (Battery low alarm).
IC103, D107,
C148
C109, R121,
C186
R114, C114,
D104
Q104, Q105,
R116, R117,
BUZZER
C148
C109, R121,
C186
R114, C114,
D104
Q104, Q105,
R116, R117,
BUZZER
(H)* BBIC Clock Adjustment
(Important)
P1.0
CLK
CLK
1. Apply 2.6V between BATTERY (+) and BATTERY (-) with DC power.
2. Execute the command “EnableClockOutput”.
3. Input Command “sfr", then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK
2. Execute the command “EnableClockOutput”.
3. Input Command “sfr", then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK
executing the command “setfreq xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
* How to de-registration (link to base unit)
1) Push handset: menu
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
* How to de-registration (link to base unit)
1) Push handset: menu
→ # → 1 → 3 → 1
2) Push handset: 0
→ 0 → 0 → 0
3) Select handset you want to de-regist.
After push OK.
Register to it on Base Unit after measurement.
After push OK.
Register to it on Base Unit after measurement.
C127, C122,
C123, X101
C123, X101
(I)* Transmitted Power
Confirmation
ANT
Remove the Antenna before starting steps from 1 to 5.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Channel: 5
• Traffic Slot: 4
• Mode: Loopback
• RFPI: 0102030405
• Traffic Channel: 5
• Traffic Slot: 4
• Mode: Loopback
2. Execute the command “testmode”.
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is -19dBm ~ 25dBm.
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is -19dBm ~ 25dBm.
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
R802, C823,
C131, C803,
C825, C110,
C802, C804
C807, C819,
C826, D803,
C817, C149,
R802, C823,
C131, C803,
C825, C110,
C802, C804
(J)* Modulation Check
ANT
Follow steps 1 to 4 of (I).
4. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data
type Fig31.
type Fig31.
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
R802, C823,
C131, C803,
C825, C110,
C802, C804
C807, C819,
C826, D803,
C817, C149,
R802, C823,
C131, C803,
C825, C110,
C802, C804
(K)* Frequency Offset
Confirmation
-
Follow steps 1 to 4 of (I).
4. Confirm that the frequency offset is -50kHz ~ +50kHz.
IC103, C813,
C807, C819,
C826, D803,
C817, C149,
R802, C823,
C131, C803,
C825, C110,
C802, C804
C807, C819,
C826, D803,
C817, C149,
R802, C823,
C131, C803,
C825, C110,
C802, C804
(L)* Sensitivity Receiver
Confirmation
-
Follow steps 1 to 4 of (I).
4. Set DECT tester power to -85dBm.
5. Confirm that the BER is < 1000ppm.
5. Confirm that the BER is < 1000ppm.
IC103, C815,
C830, C820,
C821, R801,
D803, C817,
C149
C830, C820,
C821, R801,
D803, C817,
C149
(M)* Timing Confirmation
-
Follow steps 1 to 4 of (I).
4. Confirm that the Timing accuracy is < ± 2.0ppm.
IC103, C815,
C830, C820,
C821, R801,
D803, C817,
C149
C830, C820,
C821, R801,
D803, C817,
C149
(N)* RSSI Level Confirmation -
Follow steps 1 to 4 of (I).
4. Set DECT tester power to -70dBm.
5. Execute the command “readrssi”.
6. Confirm: 9 < returned value < 13 (hex) (0E ± 5 (hex))
5. Execute the command “readrssi”.
6. Confirm: 9 < returned value < 13 (hex) (0E ± 5 (hex))
IC103, C815,
C830, C820,
C821, R801,
D803, C817,
C149
C830, C820,
C821, R801,
D803, C817,
C149
Items
Adjustment
Point
Procedure
Check or
Replace Parts
29
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
(O) Audio Check and
Confirmation
-
1. Link with BASE which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 50mA.
3. Input -45dBm(600
2. Set line voltage to 48V and line current to 50mA.
3. Input -45dBm(600
Ω)/1kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -5.5 ± 3dBm and that the distortion level is < 5% at TEL
Line (600
Ω Load).
5. Input -20dBm(600
Ω)/1kHz to Line I/F. Measure the level at Receiver of
Handset and distortion level (*Receive volume set to third position from
minimum).
minimum).
6. Confirm that the level is -23.5 ± 3dBm and that the distortion level is < 5% at
Receiver (150