DOWNLOAD Panasonic KX-TG1611RUF / KX-TG1611RUH / KX-TG1611RUJ / KX-TG1611RUR / KX-TG1611RUW / KX-TG1612RU1 / KX-TG1612RU3 / KX-TG1612RUH / KX-TGA161RUF / KX-TGA161RUH / KX-TGA161RUJ / KX-TGA161RUR / KX-TGA161RUW (serv.man2) Service Manual ↓ Size: 1.68 MB | Pages: 28 in PDF or view online for FREE

Model
KX-TG1611RUF KX-TG1611RUH KX-TG1611RUJ KX-TG1611RUR KX-TG1611RUW KX-TG1612RU1 KX-TG1612RU3 KX-TG1612RUH KX-TGA161RUF KX-TGA161RUH KX-TGA161RUJ KX-TGA161RUR KX-TGA161RUW (serv.man2)
Pages
28
Size
1.68 MB
Type
PDF
Document
Service Manual / Supplement
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg1611ruf-kx-tg1611ruh-kx-tg1611ruj-kx-tg1611ru.pdf
Date

Panasonic KX-TG1611RUF / KX-TG1611RUH / KX-TG1611RUJ / KX-TG1611RUR / KX-TG1611RUW / KX-TG1612RU1 / KX-TG1612RU3 / KX-TG1612RUH / KX-TGA161RUF / KX-TGA161RUH / KX-TGA161RUJ / KX-TGA161RUR / KX-TGA161RUW (serv.man2) Service Manual / Supplement ▷ View online

9
3.2.2.
Check Link
[Changed from original section "9.1.3. Check Link"]
3.2.2.1.
Base Unit
Cross Reference:
Power Supply Circuit (P.5)
Check Point (Base Unit) (P.12)
Note:
(*1) Refer to Troubleshooting by Symptom (Base Unit and Charger Unit) (P.12).
Check around Power Supply Circuit.
Does Base Unit make link with Handset? 
(Correct working unit)
Check around X1 and adjust clock frequency.
Refer to Check Point...(E).
NO
NO
NO
(*1)
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
Check the RF circuit in the shield case.
Is the modulation OK?
Refer to Check Point...(I).
Is VDDB pin about 2.65V?
Is there CMD60 (: Dect Tester)?
Is the RF clock (P1.0) oscillate: 10.368MHz in
Base Unit Test Mode?
Refer to Check Point...(E).
Is the NTP value OK?
Refer to Check Point...(H).
Is the RSSI Level OK?
Refer to Check Point...(M).
Does Base Unit make link with CMD60 in 
Base Unit Test Mode?
Refer to Check Point...(H).
NO
YES
Base Unit is OK. Check Handset.
NO
YES
Is the Sensitivity Receiver OK?
Refer to Check Point...(K).
YES
Is the Timing OK?
Refer to Check Point...(L).
YES
Is the Frequency Offset OK?
Refer to Check Point...(J).
10
3.2.2.2.
Handset
Cross Reference
Power Supply Circuit/Reset Circuit
Check Point (Handset)
 (P.15)
Note:
(*1) Refer to Troubleshooting by Symptom (Handset) (P.15).
Check around Power Supply Circuit/Reset Circuit.
Does Handset make link with Base Unit?
(Correct working unit)
Check around X101 and  adjust clock frequency. 
Refer to Check Point...(H).
NO
NO
NO
(*1)
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
Check the RF circuit in the shield case.
VDDBAT about 2.6 V?
Is the RF clock (P1.0) oscillate: 10.368MHz
in Base Unit Test Mode?
Refer to Check Point...(H).
Is the NTP value OK?
Refer to Check Point...(I).
Is the RSSI Level OK?
Refer to Check Point...(N).
Does Base Unit make link with CMD60 in
Base Unit Test Mode?
Refer to Check Point...(I).
NO
Handset is OK. Check Base Unit.
YES
Is there CMD60 (: Dect Tester)?
NO
YES
Is the modulation OK?
Refer to Check Point...(J).
YES
Is the Frequency Offset OK?
Refer to Check Point...(K).
YES
Is the Sensitivity Receiver OK?
Refer to Check Point...(L).
YES
Is the Timing OK?
Refer to Check Point...(M).
11
3.2.3.
Bell Reception
[Changed from original section "9.1.7. Bell Reception"]
3.2.3.1.
Handset
Cross Reference:
Telephone Line Interface
Check Link
 (P.9)
How to Check the Handset Speaker or Receiver
Does bell sound from BUZZER?
Replace with the new BUZZER.
Check around R114, D104, Q104, Q105.
When bell signal coming, is there bell sound signal 
at RA102 (P1.1) and RA102 (TXD)?
NO
NO
YES
When bell signal coming, is there bell sound signal
at D104 (between A and K)?
YES
Check link in Check Link, and around Career module.
NO
12
3.2.4.
Troubleshooting by Symptom (Base Unit and Charger Unit)
3.2.4.1.
Check Point (Base Unit)
[Changed from original section "9.2.1. Check Point (Base Unit)"]
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*:  PC Setting is required beforehand.
The connections of simulator equipment are as shown in Adjustment Standard (Base Unit) (P.18).
Items
Adjustment 
Point
Procedure
Check or 
Replace Parts
(A) 2.65V Supply
Confirmation
-
1. Confirm that the voltage between VDD and GND is 2.65V ± 0.2V.
C58, C40, F1, 
C34, IC2, R35,
R36, C28,
C11, C48, R17
(B) VDDIO Confirmation
-
1. Confirm that the voltage between C24 and GND is 2.5 ± 0.3.
IC3, X1, C22
C23, C17
(C)* BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC3, X1, C22
C23, C17
(D)* BBIC Clock Adjustment
(Important)
P1.0
CLK
1. Execute the command “EnableClockOutput”.
2. Input Command “GetFreq”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368MHz ± 100Hz, adjust the frequency of CLK
executing the command “setfreq 04 xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
IC3, X1, C22
C23, C17
(E)* Hookswitch Check with
DC Characteristics
-
1. Connect J1 (Telephone Socket) to Tel-simulator which is connected with 600
.
2. Set line voltage to 48V at on-hook condition and line current to 40mA at off-
hook condition of normal telephone.
3. Execute the command “hookoff”.
4. Confirm that the line current is 40mA ± 5mA.
5. Execute the command “hookon”.
6. Confirm that the line current is 0mA + 2mA.
IC3, C30, C31,
D2, Q3, R26,
R22, Q2, C45,
C21, R18,
R15, P101,
SA1
(F)* DTMF Generator Check -
1. Connect J1 (Telephone Socket) to DTMF tester.
2. Execute the command “hookoff” and “dtmf_up”.
3. Confirm that the high frequency (1477.06Hz) group is -3.0 ± 2dBm.
4. Execute the command “dtmf_low”.
5. Confirm that the low frequency (852.05Hz) group is -6.0 ± 2dBm.
IC3, R2, C4,
C5, R7, R9,
R10, C9, Q1,
R6, R12, D1,
Q3, R26, R22,
Q2, C45, C21,
R18, R15, D2,
C30, C31,
P101,SA1
(G)* Transmitted Power
Confirmation
-
Remove the Antenna before starting steps from 1 to 5.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Channel: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
2. Execute the command “testmode”.
3. Initiate connection from DECT tester. (“set up connect”)
4. Execute the command “ANT2”.
5. Confirm that the NTP value at ANT is 19dBm~25dBm.
IC3, C813,
P101, SA1,
C811, C812
C807, C819,
C826, D801,
C808, C810,
D6, C809,
C39, C38,
RA43, C823,
C821, RA801,
C803, C825,
C44, C806,
C802, C804,
C820, C830,
C815, L1
checksum value
ex.)
program number
DCM1EB
0152
Page of 28
Display