DOWNLOAD Panasonic KX-TG1401UAH / KX-TG1401UAL / KX-TG1402UA3 / KX-TG1411UAM / KX-TG1411UAT / KX-TG1412UA1 / KX-TGA131RUH / KX-TGA131RUL / KX-TGA131RUM / KX-TGA131RUT Service Manual ↓ Size: 1.6 MB | Pages: 60 in PDF or view online for FREE

Model
KX-TG1401UAH KX-TG1401UAL KX-TG1402UA3 KX-TG1411UAM KX-TG1411UAT KX-TG1412UA1 KX-TGA131RUH KX-TGA131RUL KX-TGA131RUM KX-TGA131RUT
Pages
60
Size
1.6 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg1401uah-kx-tg1401ual-kx-tg1402ua3-kx-tg1411ua.pdf
Date

Panasonic KX-TG1401UAH / KX-TG1401UAL / KX-TG1402UA3 / KX-TG1411UAM / KX-TG1411UAT / KX-TG1412UA1 / KX-TGA131RUH / KX-TGA131RUL / KX-TGA131RUM / KX-TGA131RUT Service Manual ▷ View online

21
KX-TG1401UA/KX-TG1402UA/KX-TG1411UA/KX-TG1412UA/KX-TGA131RU
9.1.3.
Check Link
9.1.3.1.
Base Unit
Cross Reference:
Power Supply Circuit (P.8)
Check Point (Base Unit) (P.24)
Note:
(*1) Refer to Troubleshooting by Symptom (Base Unit and Charger Unit) (P.24).
22
KX-TG1401UA/KX-TG1402UA/KX-TG1411UA/KX-TG1412UA/KX-TGA131RU
9.1.3.2.
Handset
Cross Reference
Power Supply Circuit/Reset Circuit (P.11)
Check Point (Handset) (P.27)
Note:
(*1) Refer to Troubleshooting by Symptom (Handset) (P.27).
23
KX-TG1401UA/KX-TG1402UA/KX-TG1411UA/KX-TG1412UA/KX-TGA131RU
9.1.4.
Check Handset Transmission
Cross Reference:
Signal Route (P.12)
9.1.5.
Check Handset Reception
Cross Reference:
How to Check the Handset Speaker or Receiver (P.42).
Signal Route (P.12)
9.1.6.
Check Caller ID
Cross Reference:
Signal Route (P.12)
9.1.7.
Bell Reception
9.1.7.1.
Handset
Cross Reference:
Telephone Line Interface (P.9)
Check Link (P.21)
How to Check the Handset Speaker or Receiver (P.42)
24
KX-TG1401UA/KX-TG1402UA/KX-TG1411UA/KX-TG1412UA/KX-TGA131RU
9.2.
Troubleshooting by Symptom (Base Unit and Charger Unit)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not. 
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Base Unit) (P.24)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*: The Setting Method of JIG (Base Unit) (P.33) is required beforehand.
The connections of simulator equipment are as shown in Adjustment Standard (Base Unit) (P.35).
Items
Adjustment 
Point
Procedure
Check or 
Replace Parts
(A) 2.6V Supply
Confirmation
-
1. Confirm that the voltage between VDDPA/RF and GND is 2.65V ± 0.2V.
C58,  F1,  D5,
C35, C34,
C59, IC4, R46,
R45, C47,
C46, C29,
C44, C33
(B) 3.3V Supply
Confirmation
-
1. Confirm that the voltage between VDD and GND is 4.0V ± 0.2V.
C58,  F1,  D5,
C35, C34,
C59, IC2, R35,
R36, C60,
C28, C25, C11
(C) VDDIO Confirmation
-
1. Confirm that the voltage between C24 and GND is 2.85 ± 0.3.
Career
module(IC3),
X1, C3
(D)* BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
Career
module, X1,
C23
(E)* BBIC Clock Adjustment
(Important)
P1.1
CLK
1. Execute the command “EnableClockOutput”.
2. Input Command “rdeeprom 00 00 02”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368MHz ± 100Hz, adjust the frequency of CLK
executing the command “setfreq sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.