DOWNLOAD Panasonic KX-TG1311CAH / KX-TG1311CAL / KX-TG1311CAV / KX-TG1312CA2 / KX-TG1312CA3 / KX-TGA131RUA / KX-TGA131RUH / KX-TGA131RUL / KX-TGA131RUV Service Manual ↓ Size: 1.99 MB | Pages: 67 in PDF or view online for FREE

Model
KX-TG1311CAH KX-TG1311CAL KX-TG1311CAV KX-TG1312CA2 KX-TG1312CA3 KX-TGA131RUA KX-TGA131RUH KX-TGA131RUL KX-TGA131RUV
Pages
67
Size
1.99 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / TELEPHONE EQUIPMENT
File
kx-tg1311cah-kx-tg1311cal-kx-tg1311cav-kx-tg1312ca.pdf
Date

Panasonic KX-TG1311CAH / KX-TG1311CAL / KX-TG1311CAV / KX-TG1312CA2 / KX-TG1312CA3 / KX-TGA131RUA / KX-TGA131RUH / KX-TGA131RUL / KX-TGA131RUV Service Manual ▷ View online

37
KX-TG1311CAH/KX-TG1311CAL/KX-TG1311CAV/KX-TG1312CA2/KX-TG1312CA3/KX-TGA131RUA/KX-TGA131RUH/KX-TGA131RUL/KX-TGA131RUV
11 Measurements and Adjustments
11.1. The Setting Method of JIG (Base Unit)
11.1.1. Preparation
11.1.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: it must be precise to be able to measure 1Hz (precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
• DC power: it must be able to output at least 1A current under 9V.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.1.1.2. JIG and PC
• Serial JIG
PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG1311CA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300
and TCD500 series. (It is an upper compatible JIG Cable.)
11.1.2. PC Setting
11.1.2.1. Connections
Connect the AC adaptor to J2 (base unit).
Serial JIG to the Serial Port of PC.
Connect the Clip cable GND.
Connect the Clip cable UTX and URX.
Note:
*: Com port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New value (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
38
KX-TG1311CAH/KX-TG1311CAL/KX-TG1311CAV/KX-TG1312CA2/KX-TG1312CA3/KX-TGA131RUA/KX-TGA131RUH/KX-TGA131RUL/KX-TGA131RUV
11.1.2.2. Batch file Setting
Note:
• “*****” varies depending on the country.
11.1.2.3. Commands
• See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address “00 00” to “FF” is
read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E 98” is written.
setfreq
adjust Frequency of RFIC
Type “setfreq nn nn”.
hookoff
off-hook mode on Base
Type “hookoff”.
hookon
on-hook mode on Base
Type “hookon”.
Getchk
Read checksum
Type “getchk”.
Wreeprom
write eeprom
Type “wreeprom 01 23 45”. “01 23” is address and “45” is data to be written.
InitBsPIN.bat
Initial Base PIN to “0000”
Type “initBsPIN”
39
KX-TG1311CAH/KX-TG1311CAL/KX-TG1311CAV/KX-TG1312CA2/KX-TG1312CA3/KX-TGA131RUA/KX-TGA131RUH/KX-TGA131RUL/KX-TGA131RUV
11.2. Adjustment Standard (Base Unit)
When connecting the simulator equipments for checking, please refer to below.
11.2.1. Bottom View
Note:
(A) - (O) is referred to Check Point (Base Unit) (P.28)
P1.1
VDD
LINE_DC
DC_IN
GND
RXD
VDDPA/RF
DCM
DCP
L1R
L1T
L2R
L2T
TXD
Charge
MD2
MD1
MD0
Charge+
C
RXD
TXD
GND
L1T
L1R
DTMF
Tester
Call - ID
Simulator
BELL
Simulator
LOOP
Simulator
AF
OSC
AF VOLT
METER
OSC
OSC
600
150
SP
Serial
JIG
PC
AF VOLT
METER
Dummy Handset
MIC
AF
OSC
6.3 V 47   F 
Digital
Volt Meter
12
2W
CHARGE-
CHARGE+
4.7k
Digital
Volt Meter
LINE_DC
GND
Digital
Volt Meter
VDD
GND
Frequency
Counter
CLK
GND
DC_IN
GND
DC POWER
DC 6.5V
GND
ANT
DECT Tester
CTS60
(O)
(D)
(N)
(B)
(E)
(F), (G), (O)
(H), (I), (J)
(K), (L), (M)
(A)
40
KX-TG1311CAH/KX-TG1311CAL/KX-TG1311CAV/KX-TG1312CA2/KX-TG1312CA3/KX-TGA131RUA/KX-TGA131RUH/KX-TGA131RUL/KX-TGA131RUV
11.3. Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
11.3.1. Bottom View
Note:
(A) is referred to Check Point (Charger Unit) (P.30)
TP4
TP3
1
2
J1
D1
A
F1
PbF
PQLV30055
PQLV30056
PQUP11532Z
Charge-
Charge+
10    /2 W
Digital
Volt Meter
(A)
DC POWER
DC 6.5 V
TP3
TP4 (GND)
Page of 67
Display

Click on the first or last page to see other KX-TG1311CAH / KX-TG1311CAL / KX-TG1311CAV / KX-TG1312CA2 / KX-TG1312CA3 / KX-TGA131RUA / KX-TGA131RUH / KX-TGA131RUL / KX-TGA131RUV service manuals if exist.