DOWNLOAD Panasonic KX-TCD816UAS / KX-TCD816UAT / KX-TCA181UAS / KX-TCA181UAT Service Manual ↓ Size: 1.99 MB | Pages: 101 in PDF or view online for FREE

Model
KX-TCD816UAS KX-TCD816UAT KX-TCA181UAS KX-TCA181UAT
Pages
101
Size
1.99 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / TELEPHONE EQUIPMENT
File
kx-tcd816uas-kx-tcd816uat-kx-tca181uas-kx-tca181ua.pdf
Date

Panasonic KX-TCD816UAS / KX-TCD816UAT / KX-TCA181UAS / KX-TCA181UAT Service Manual ▷ View online

KX-TCD816UAS
KX-TCD816UAT
KX-TCA181UAS
KX-TCA181UAT
Digital Cordless Phone
Silver Version
Titanium Black Version
(for Ukraine)
Telephone Equipment
ORDER NO. KM40509869CE
  1 ABOUT LEAD FREE SOLDER (PbF: Pb free) 
4
  1.1.  Suggested PbF Solder 
4
  1.2.  How to recognize that Pb Free solder is used 
5
  2 FOR SERVICE TECHNICIANS 
5
  3 CAUTION 
5
  4 OPERATING INSTRUCTIONS 
6
  4.1.  Battery 
6
  4.2.  Location ofControls 
7
  4.3.  Connections 
8
  4.4.  Guide to Settings 
9
  4.5.  For Service Hint 
11
  5 DISASSEMBLY INSTRUCTIONS 
12
  5.1.  Base Unit 
12
  5.2.  Handset 
13
  5.3.  Charger Unit 
15
  6 ASSEMBLY INSTRUCTIONS 
16
  6.1.  Fix the LCD to the Main P.C.Board (Handset) 
16
  7 TROUBLESHOOTING FLOWCHART 
17
  7.1.  Check Power 
18
  7.2.  Check Battery Charge 
19
  7.3.  Check Link 
20
  7.4.  Check Handset Transmission 
24
  7.5.  Check Handset Reception 
24
  7.6.  Check Caller ID 
24
  7.7.  Bell Reception 
25
  8 TROUBLESHOOTING BY SYMPTOM (BASE UNIT AND
CHARGER UNIT) 
26
  8.1.  Check Point (Base Unit) 
26
  8.2.  The Setting Method ofJIG (Base Unit) 
30
  8.3.  Adjustment Standard (Base Unit) 
32
  8.4.  Check Point (Charger Unit) 
34
  8.5.  Adjustment Standard (Charger Unit) 
34
  9 TROUBLESHOOTING BY SYMPTOM (HANDSET) 
35
  9.1.  Check Point (Handset) 
35
  9.2.  The Setting Method ofJIG (Handset) 
39
  9.3.  Adjustment Standard (Handset) 
41
 10 THINGS TO DO AFTER REPLACING IC 
42
  10.1.  Base Unit 
42
  10.2.  Handset 
42
 11 RF SPECIFICATION 
43
  11.1.  Base Unit 
43
  11.2.  Handset 
43
 12 HOW TO CHECK THE HANDSET SPEAKER OR RECEIVER  44
 13 FREQUENCY TABLE (MHz) 
44
 14 BLOCK DIAGRAM (BASE UNIT) 
45
 15 CIRCUIT OPERATION (BASE UNIT) 
46
  15.1.  Outline 
46
  15.2.  Power Supply Circuit 
47
  15.3.  Telephone Line Interface 
48
  15.4.  Transmitter/Receiver 
48
  15.5.  Pulse Dialling 
48
 16 BLOCK DIAGRAM (HANDSET) 
49
 17 CIRCUIT OPERATION (HANDSET) 
50
  17.1.  Outline 
50
  17.2.  Power Supply Circuit/Reset Circuit 
50
  17.3.  Charge Circuit 
50
  17.4.  Battery Low/Power Down Detector 
50
  17.5.  Speakerphone 
51
 18 CIRCUIT OPERATION (CHARGER UNIT) 
52
  18.1.  Power Supply Circuit 
52
 19 SIGNAL ROUTE 
53
 20 CPU DATA (BASE UNIT) 
54
  20.1.  IC8 (BBIC) 
54
 21 CPU DATA (HANDSET) 
56
  21.1.  IC1 (BBIC) 
56
 22 ENGINEERING MODE 
59
  22.1.  Base Unit 
59
  22.2.  Handset 
62
 23 EEPROM LAYOUT (BASE UNIT) 
64
  23.1.  Scope 
64
  23.2.  Introduction 
64
  23.3.  EEPROM Layout 
64
 24 FLASH LAYOUT (HANDSET) 
69
  24.1.  Scope 
69
Note:
Because CONTENTS 4 is the extract from the Operating Instructions of this model, it is subject to change without notice. You can
download and refer to the original Operating Instructions on TSN Server for further information.
CONTENTS
 
Page 
Page
2
KX-TCD816UAS / KX-TCD816U AT / KX-TCA181UAS / KX-TCA181UAT
  24.2.  Introduction 
69
  24.3.  FLASH contents 
69
 25 HOW TO REPLACE THE FLAT PACKAGE IC 
72
  25.1.  PREPARATION 
72
  25.2.  FLAT PACKAGE IC REMOVAL PROCEDURE 
72
  25.3.  FLAT PACKAGE IC INSTALLATION PROCEDURE 
73
  25.4.  BRIDGE MODIFICATION PROCEDURE 
73
 26 CABINET AND ELECTRICAL PARTS (BASE UNIT) 
74
 27 CABINET AND ELECTRICAL PARTS (HANDSET) 
75
 28 CABINET AND ELECTRICAL PARTS (CHARGER UNIT) 
76
 29 ACCESSORIES AND PACKING MATERIALS 
77
  29.1.  KX-TCD816UAS/UAT 
77
  29.2.  KX-TCA181UAS/UAT 
78
 30 TERMINAL GUIDE OF THE ICs, TRANSISTORS AND DIODES
 
79
  30.1.  Base Unit 
79
  30.2.  Handset 
79
  30.3.  Charger Unit 
80
 31 REPLACEMENT PARTS LIST 
81
  31.1.  Base Unit 
81
  31.2.  Handset 
83
  31.3.  Charger Unit 
85
  31.4.  Accessories and Packing Materials 
86
  31.5.  Fixtures and Tools 
86
 32 FOR SCHEMATIC DIAGRAM 
87
  32.1.  Base Unit (SCHEMATIC DIAGRAM (BASE UNIT)) 
87
  32.2.  Handset (SCHEMATIC DIAGRAM (HANDSET)) 
87
  32.3.  Charger Unit (SCHEMATIC DIAGRAM (CHARGER UNIT))
 
87
 33 SCHEMATIC DIAGRAM (BASE UNIT) 
88
 34 SCHEMATIC DIAGRAM (HANDSET) 
90
 35 SCHEMATIC DIAGRAM (HANDSET_OPERATION) 
92
 36 SCHEMATIC DIAGRAM (CHARGER UNIT) 
93
 37 CIRCUIT BOARD (BASE UNIT) 
95
  37.1.  Component View 
95
  37.2.  Flow Solder Side View 
96
 38 CIRCUIT BOARD (HANDSET) 
97
  38.1.  Component View 
97
  38.2.  Flow Solder Side View 
98
 39 CIRCUIT BOARD (HANDSET_OPERATION) 
99
  39.1.  Component View 
99
  39.2.  Flow Solder Side View 
100
 40 CIRCUIT BOARD (CHARGER UNIT) 
101
  40.1.  Component View 
101
  40.2.  Flow Solder Side View 
101
3
KX-TCD816UAS / KX-TCD816U AT / KX-TCA181UAS / KX-TCA181UAT
1  ABOUT LEAD FREE SOLDER (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that
contains lead.
We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn),
Silver (Ag), and Copper (Cu).
This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair
work we suggest using the same type ofsolder although, with some precautions, standard Pb solder can also be used.
Caution
     • 
• 
• 
• PbF solder has a melting point that is 50°F ~ 70°F (30°C ~ 40°C) higher than Pb solder. Please use a soldering iron with
temperature control and adjust it to 700°F ± 20°F (370°C ± 10°C). In case ofusing high temperature soldering iron, please
be careful not to heat too long.
     • 
• 
• 
• PbF solder will tend to splash ifit is heated much higher than its melting point, approximately 1100°F (600°C).
     • 
• 
• 
• Ifyou must use Pb solder on a PCB manufactured using PbF solder, remove as much ofthe original PbF solder as possible
and be sure that any remaining is melted prior to applying the Pb solder.
     • 
• 
• 
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the
opposite side (See the figure below).
1.1. 
Suggested PbF Solder
There are several types ofPbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper
(Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the
manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other
materials.
The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3mm, 0.6mm and 1.0mm.
4
KX-TCD816UAS / KX-TCD816U AT / KX-TCA181UAS / KX-TCA181UAT
Page of 101
Display

Panasonic KX-TCD816UAS / KX-TCD816UAT / KX-TCA181UAS / KX-TCA181UAT Service Manual ▷ Download

  • DOWNLOAD Panasonic KX-TCD816UAS / KX-TCD816UAT / KX-TCA181UAS / KX-TCA181UAT Service Manual ↓ Size: 1.99 MB | Pages: 101 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic KX-TCD816UAS / KX-TCD816UAT / KX-TCA181UAS / KX-TCA181UAT in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic KX-TCD816UAS / KX-TCD816UAT / KX-TCA181UAS / KX-TCA181UAT Telephone. Information contained in Panasonic KX-TCD816UAS / KX-TCD816UAT / KX-TCA181UAS / KX-TCA181UAT Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.