DOWNLOAD Panasonic KX-TCD715GM Service Manual ↓ Size: 2.93 MB | Pages: 99 in PDF or view online for FREE

Model
KX-TCD715GM
Pages
99
Size
2.93 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DECT
File
kx-tcd715gm.pdf
Date

Panasonic KX-TCD715GM Service Manual ▷ View online

15.3.6.  PSTN Line
Address
Default
Name
Type
Description
0F00
03
UserCfg-1.Mode
D
User configuration (MMI) - mode settings 1.
Bit
0 : "R" mode, 0=earth break, 1=loop break
2..1: Dial mode, 00:pulse, 01:DTMF
3..7: Reserved
0F01
0D
UserCfg-2.Mode
D
User configuration (MMI) - mode settings 2.
Bit
0..1: short "R" key time selection
00= short, 01=long, 10=extra-long
2..3: long "R" key time selection
00= short, 01=long, 10=extra-long,
11=undef (uses same time as specified for short R key)
4..7: Reserved
Defaults to 0000 1101
0F02
10
UserCfg.RPauseTime
D
User configuration (MMI) - "R"-pause. If disabled, normal
dial pause (DialPauseTime) is used.
Bit 7..0 : "R" pause time, zero value allowed
Unit : 50 ms, defaults to 800 ms.
0F03
03
UserCfg.DialPauseTime
D
User configuration (MMI) - dial pause.
Bit 3-0 : dial pause in 1 sec units , zero not allowed.
Bit 7-4 : unused
Defaults to 3 seconds
0F04
0F
Cfg-1
D
PSTN line configuration 1 (factory settings)
Bit
0: EarthBreakEnable , Earth break 1=enable 0=disable
1:LoopBreakEnable, Loop break 1=enable,0=disable
2:PulseDialEnable, Pulse dial 1=enable 0=disable
3:RPauseEnable, usage of "R" pause 1=enable, 0=disable
4:PulseType,0=normal puls-type
1=(’0’=1 pils,..’9’=10 puls’s).
5: InterDigitLowImp. controls interdigit impedance.
1: keep low-impedance during interdigit pause
0: normal impedance during interdigit pause
6:
LowImpLineSeizure.
Special
low-imp
line
seizure
(Australian) , 1=enable , 0=disable
7: TwoLines. line config 0=one line, 1=two lines Defaults to
0000 0111B.
0F05
15
Cfg-2
PSTN line configuration 2 (factory settings)
Bit
0: Meter-pulse, 1=enable, 0=disable
1: DialToneMode, dial tone detection 1=enable 0=disable
2: BusyToneMode. busy tone detection 1=enable 0=disable
3: CurrentLimiterMode, 1=enable, 0=disable
4: RingToneMode. Ring tone detection 1=enable 0=disable
5: HookRelayEnable, 1=enable, 0=disable (if same port is
used
for
earth-control
EarthBreakEnable
and
HookRelayEnable cannot both be set to 1).
6..7: not used
Defaults to 0001 0101B.
0F06
28
MakeTime
D
Pulse make time.
Unit : 1 ms. defaults to 40 ms.
0F07
3C
BreakTime
D
Pulse break time
Unit : 1 ms, defaults to 60 ms.
0F08
64
DtmfTime
D
DTMF tone pulse time.
Unit : 1 ms, defaults to 100 ms.
0F09
0A
InterDigitDtmfTime
D
Inter-digit time in DTMF mode.
Unit : 10 ms , defaults to 100ms.
0F0A
4A
InterDigitPulseTime
D
Inter-digit time in Pulse mode.
Unit : 10 ms, defaults to 740 ms.
0F0B
08
CalibBreakTime[0]
D
Calibrated loop-break time for short break
Unit : 10 ms, defaults to 80 ms.
0F0C
14
CalibBreakTime[1]
D
Calibrated loop-break time for long break
Unit : 10 ms, defaults to 200 ms.
0F0D
46
CalibBreakTime[2]
D
Calibrated loop-break time for extra-long break
Unit : 10 ms, defaults to 700 ms.
0F0E
28
CalibBreakTime[3]
D
Calibrated earth-break time for short break
Unit : 10 ms, defaults to 400 ms.
0F0F
82
CalibBreakTime[4]
D
Calibrated earth-break time for long break
Unit : 10 ms, defaults to 1300 ms.
0F10
82
CalibBreakTime[5]
D
Calibrated earth-break time for extra-long break
Unit : 10 ms, defaults to 1300 ms.
0F11
FF
LineSeizureEndTime
D
Line seizure end-time - time after hook-on. Meter-pulse
detection continues during this period of time. 00h or FFh
means 10 ms.
Unit : 10 ms, defaults to 10 ms.
69
KX-TCD715GM
Address
Default
Name
Type
Description
0F12
64
RingTermToU100
D
Ring terminate time-out period. This is the max time that
must elapse between two ring-voltage bursts before the
new ring-voltage is registered as a new incoming call.
Unit: 100 ms. defaults to approx 10 sec.
0F13
08
RingPatternToU100
D
Ring pattern timeout. Max. silence period during distinctive
ringing. As long as the silence period does not exceed this
period of time the ring is still considered and counted as
one single ring.
Unit : 100 ms. Defaults to 800 ms
0F14
FF
AgcUpdateTime
Line AGC update time. The period of time between each
line AGC update. If FFh, line-AGC is disabled. If used
recommended value is 64h (1 sec).
Unit : 10ms, min/max: 10/FF, Defaults to disabled.
0F15
0A
LineSeizureTime
Line seizure time. The period of time that the PSTN line or
the PSTN HW needs after the hook-switch is activated in
order to be ready. During this period audio is muted. Only
used during outgoing calls or if the special-line seizure
mode is enabled (Cfg:6).
Unit : 10 ms, min/max: 01/FF. Defaults to 100 ms.
0F16
66
InitDialPause
D
Init-dial-pause. Dial pause inserted after hook-off when
making an outgoing call.
Bit 0..3: init dial pause if PULSE dial-mode. If 0fH then
normal dial-pause is used.
Bit 4..7: init dial pause if DTMF dial-mode. if 0fH then
normal dial-pause is used.
Unit : 500 ms, min/max: 00/0F. Defaults to 3 sec and 3 sec.
0F17..1BB
FF..FF
Reserved[5]
D
15.3.7.  Clip configration
Address
Default
Name
Type
Description
0F37.. 38
3D 00
Parse.Configuration
D
Clip parse set configuration
Bit
0: Etsi: 1=enable 0=disable
1: ForwardNumber: 1=enable 0=disable
2: Danish: 1=enable 0=disable
3: Dutch: 1=enable 0=disable
4: Canadian: 1=enable 0=disable
5: Swedish: 1=enable 0=disable
6: UserDefined: 1=enable 0=disable
7: KPN vmwi: 1=enable 0=disable
8: Reserved8
9: Reserved9
10: Reserved10
11: Reserved11
12: Reserved12
13: Reserved13
14: Reserved14
15: Reserved15
15.3.8.  BsUiTask
Address
Default
Name
Type
Description
0FFD
(TCD715 /
TCD735 0xFF
(TCD700 /
TCD705 /
TCD725) 0xF7
Config
D
BsUiTask configuration
Bits 1=enable 0=disable
0: FlashTime1Enabled.
1: FlashTime2Enabled.
2: FlashTime3Enabled.
3: KeyClicksEnabled:
TCD700 / TCD705 / TCD725: Default disabled TCD715 /
TCD735: Default enabled
4: ARSCarrierMenuEnabled.
5: ARSIntDeletionMenuEnabled.
6: ARSMultipleCarrierMenuEnabled.
7: ARSMultipleAreaCodeMenuEnabled.
0FFE
(step6)
0x01
(step5)
0x05
Kamma4BaseModelId
A
Kamma4 Base Model Identifier:
0x01 = TCD7000
0x02 = TCD7050
0x03 = TCD715
0x04 = TCD725
0x05 = TCD735
70
KX-TCD715GM
15.3.9.  SP phone setting
Address
Value
0d67
0b
0d68
7f
0d6a
7f
0d6c
fd
0d6d
10
0d6e
40
0d6f
4f
0d70
58
0d71
5f
0d74
50
0d75
10
0d76
60
0d77
10
0d79
40
71
KX-TCD715GM
15.4.  Appendix
15.4.1.  Gain for transmit and receive
[dB]
[dB]
[dB]
[dB]
[dB]
00 00
16.06
31 15
5.92
BB 22
2.72
39 20
11.02
48 D7
29.51
00 01
16.9
21 41
5.73
A B 92
2.92
A 9 24
11.2
98 C6
29.97
00 02
16.26
0B 93
5.53
3A15
3.11
98 C2
11.39
C6 D6
30.4
00 03
16.92
12 C3
5.34
BAC0
3.3
39 14
11.58
C6 DE
30.8
00 0D
15.47
21 BB
5.14
A B B5
3.5
A 9 22
11.77
B8 E0
31.26
00 0B
15.19
0A94
4.94
19 35
3.7
9A0D
11.91
38 E1
31.58
00 11
14.81
0B 41
4.74
A B 31
3.89
99 52
12.39
48 E1
32.08
00 12
14.4
32 10
4.54
2A10
4.08
C9 15
12.88
A 8 D7
32.53
00 1D
13.92
22 23
4.35
AA A5
4.28
99 33
13.36
A 8 DD
32.88
00 21
13.53
31 B5
4.16
AA B1
4.47
99 31
13.84
C8 E1
33.16
00 2D
13.03
22 4B
3.97
AA BC
4.66
A 8 A 5
14.27
48 E2
33.66
00 3C
12.54
22 CC
3.77
AA CA
4.66
99 24
14.72
28 E7
34.12
01 10
12.04
32 21
3.59
B9 A3
5.03
C8 B1
15.1
48 E3
34.57
00 BB
11.55
32 25
3.4
AA 42
5.23
48 B2
15.6
48 E4
35.07
00 B3
11.41
23 30
3.2
AA 33
5.41
28 B7
16.06
48 E7
35.53
00 B2
11.33
23 4A
3.01
39 44
5.5
48 B3
16.51
98 D6
35.99
00 B1
11.19
23 B2
2.81
AA 25
5.78
48 B4
17.01
C8 E5
38.42
01 13
11.04
32 B1
2.63
AA 22
5.96
48 B7
17.47
C8 EE
36.82
00 A5
10.84
1B CB
2.43
B9 B5
6.13
96 A6
17.93
B8 D9
37.28
00 A3
10.72
1B 41
2.24
39 33
6.31
CB B5
18.36
A 8 E3
37.6
01 21
10.57
1B 30
2.05
98 93
6.51
C8 BE
18.76
A 8 E4
38.1
01 22
10.4
33 B1
1.86
AA 14
6.69
B8 C0
19.22
A 8 E7
38.55
01 2D
10.22
33 A1
1.68
9B AD
6.89
38 C1
19.54
A 8 ED
38.9
01 31
10.07
33 93
1.49
9B C2
7.06
48 C1
20.03
C8 EA
39.18
01 3C
9.88
1AC1
1.29
9B 42
7.28
A 8 B7
20.49
B8 EA
39.78
01 4A
9.68
2B A5
1.09
9B 2C
7.48
A 8 B0
20.84
98 E2
40.21
02 0D
9.5
2B C1
0.89
B9 4B
7.67
C8 C1
21.12
98 E3
41.12
10 CB
9.3
2B 44
0.7
A 9 C2
7.87
48 C2
21.62
98 E4
41.62
10 C1
9.13
3B 94
0.5
A 9 C8
6.06
28 C7
22.06
98 E7
42.06
10 B4
8.95
2B 21
0.3
9AC1
6.25
48 C3
22.53
98 ED
42.42
01 A5
8.76
2B 15
0.11
99 95
8.43
48 C4
23.03
C8 E9
42.7
02 21
8.59
3B CA
0.08
9A49
8.61
48 C7
23.49
B8 E9
43.3
02 25
8.4
09 49
0.28
9A41
8.8
98 B6
23.95
A 8 E9
44.64
02 33
8.2
3B 24
0.47
B9 31
8.98
C8 C5
24.38
29 0F
46.23
02 49
8.01
1A14
0.67
9A2B
9.18
C8 CE
24.78
39 0F
47.14
02 C2
7.82
3B 13
0.86
A 9 41
9.37
B8 D0
25.24
49 0F
47.64
02 B1
7.63
3AB2
1.03
A 9 38
9.53
38 D1
25.56
98 E9
48.16
20 BC
7.43
2A2B
1.22
A 9 35
9.72
48 D1
26.05
C9 0F
48.73
11 43
7.24
2A23
1.42
99 A3
9.89
A 8 C7
26.51
B9 0F
49.32
03 49
7.07
3A4A
1.61
B9 23
10.05
A B CD
26.86
A 9 0F
50.66
21 14
6.88
09 31
1.8
9A14
10.21
C8 D1
27.14
99 0F
54.19
11 BD
6.69
BB A4
2
29 15
10.38
48 D2
27.64
88 00
1"10^10
30 BD
6.5
BB BB
2.19
99 B1
10.55
28 D7
28.1
12 15
6.31
BB 4A
2.38
29 14
10.66
48 D3
28.55
21 2C
6.11
BB 31
2.56
A 9 2C
10.84
48 D4
29.05
72
KX-TCD715GM
Page of 99
Display

Click on the first or last page to see other KX-TCD715GM service manuals if exist.