Circuit Diagram
33
KX-TCD700RUB / KX-TCD700RUC
6.2. RF SECTION
6.2.1. BLOCK DIAGRAM RF SECTION (HANDSET)
The RF section consists of two main components: The PMB6610 transceiver and the PMB6618 power amp.
In the transceiver the 10.368MHz clock signal SYCL is multiplied to around 1.9GHz using PLL (Phase Locked Loop) control.
The TXDA signal is used to control the modulation of this frequency to 1.87GHz to 1.93GHz.
Received signals are demodulated, filtered and sent to the BBIC via the RXDA line.
34
KX-TCD700RUB / KX-TCD700RUC
7 CHECK PROCEDURE (BASE UNIT)
7.1. EQUIPMENT REQUIRED
7.2. INITIAL POWER TESTS
 1. Turn on the 9V supply.
 2. Check for approx. 100mA current on the 9V supply line.
 3. Check the 3.8V supply rail at TP91. It must be 3.8V ± 0.2V.
 4. Check the 2.65V supply rail at TP95. It must be 2.65V ± 0.2V.
35
KX-TCD700RUB / KX-TCD700RUC
7.3. SET THE CLOCK FREQUENCY
 1. Turn on the 9V supply.
 2. Enter "DEACTMAC" from the PC to switch off the RF unit.
 3. Enter "CONTTX 0" to start continuous RF transmission.
 4. Enter "RDEEPROM 00 00 0F" to display the first 15 hexadecimal bytes of the EEPROM.
The frequency adjustment value is displayed in the first two locations with the most significant byte (MSB) first.
 5. Connect the frequency counter probe to TP101, or pin12 of the RF module, to measure the SYRI signal from the BBIC.
 6. The clock frequency should be within 10,368,000Hz ± 10Hz. If not then enter "SETFREQ nn nn" where nn nn are the clock
frequency adjustment values. An increase in the value will lower the clock frequency and vice versa. The maximum value is 01
FF.
 7. Switch off the 9V supply.
7.4. LOOPBACK TESTS
 1. Switch on the 9V supply.
 2. Set the CMD60 to MANUAL TEST mode.
 3. Set the CMD60 TRAFFIC CARRIER to 0.
 4. Invoke the "TESTMODE" batch file from the PC.
 5. Press ACCEPT RFPI and SETUP CONNECT on the CMD60.
 6. Check the power (NTP): it must be between 20 and 25dBm.
 7. Press MODULATION.
 8. Set DATA TYPE to FIG 31.
 9. Check frequency drift: must be 0 ± 35 kHz/ms.
 10. Check frequency offset: must be 0 ± 40 kHz.
 11. Check deviation or modulation (max ± B field) with data type "FIG 31": must be 270kHz to 380kHz.
 12. Press Menu Up "
" on the CMD60.
 13. Press POWER RAMP.
 14. Check that the burst fits the mask.
 15. Press Menu Up "
" on the CMD60.
 16. Press BER.
 17. Obtain the sensitivity by slowly reducing RF LEVEL until the BER falls below 1000ppm. The sensitivity is the RF LEVEL reading
at this point. It must be < -88dBm.
 18. Press Menu Up "
" on the CMD60.
 19. Press BEARER RELEASE and switch off the 9V supply.
Note:
These tests can also be repeated on TRAFFIC CARRIERS 5 and 9.
36
KX-TCD700RUB / KX-TCD700RUC
Page of 89
Display

Click on the first or last page to see other KX-TCD700RUB / KX-TCD700RUC service manuals if exist.