13.2.2.  Flow Solder Side View
Digital
Volt Meter
TP5
TP15
(C)
Digital
Volt Meter
TP14
TP5
(A)
TP9 TP5
DC_6V
+
-
(Q)
Digital
Volt Meter
TP5
TP22
(B)
DTMF
tester
Tel
Simulator
TP21
TP19
(H)
(G)
TP17
TP11
TP15
JT AG
TP14
TP12
TP5
TP4
1
1
10
3
5
2
4
6
TP7
TP9
TP29
TP24
TP22
TP19
TP21
TP20
GND
UTX
URX
DC_IN
PbF
CHARGE
CHARGE
Frequency
Counter
TP17
(F)
TP5
Digital
Volt Meter
(Q)
TP11
TP5
12ohm
PC
UTX
URX
GND
(C) (D) (E) (F) 
(G) (H) (I) (J)
Digital
Volt Meter
(G)
Note:
(A) - (Q) is referred to Adjustment (Base Unit) (P.48)
KX
-T
CD5
66RUS
/
K
X
-T
CA1
58RUS
53
13.3.  Adjustment (Charger Unit)
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(A)
Charging Check
-
  1. Connect Charge Contact 12
/2W resistor between charge+ and charge-.
  2. Measure and confirm voltage across the resistor is 2.7V ± 0.2V.
IC601, IC602,
C601, D601,
CN601
Note:
After the measuring, sock up the solder of TP.
The connection ofadjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.54).
13.4.  Adjustment Standard (Charger Unit)
When connecting the Simulator Equipment for checking, please refer to below.
13.4.1.  Flow Solder Side View
CII
C603
R601 R602 R603
C608
JT601 JT602
Vtc
Vsw
Iw
1
4
5
8
Vo
Vin
Vop V+
V-
Isens
GND
IC601
CIRCUIT BOARD (CHARGER UNIT) 
Flow Solder Side View
Digital Volt Meter
12
/2W
(A)
Note:
(A) is referred to Adjustment (Charger Unit) (P.54).
54
KX-TCD566RUS / KX-TCA158RUS
14 ADJUSTMENTS (HANDSET)
If your unit have below symptoms, adjust or confirm each item using remedy column from the table.
Symptom
Remedy*
The movement ofBattery Low indicator is wrong.
Make adjustments in item (A)~(C), (F), (G)
The handset does not respond to a call from base unit.
Make adjustments in item (A)~(C), (H)~(O)
The handset does not transmit or the transmit frequency is off.
Make adjustments in item (A)~(C), (H)~(K), (L), (N)
The transmit frequency is off.
Make adjustments in item (A)~(C), (H)~(K), (L), (N)
The transmit power output is low, and the operating distance between base unit and
handset is less than normal.
Make confirmation in item (I), (M)
The reception sensitivity ofbase unit is low with noise.
Make confirmation in item (M)
Does not link between base unit and handset.
Make adjustments in item (A)~(C), (H)~(O)
The Audio level is high or low.
Make confirmation in item (Q)
The SP-Phone level is high or low.
Make confirmation in item (R)
The Headset level is high or low.
Make confirmation in item (S)
*: Refer to Adjustment (Handset) (P.55)
14.1.  Adjustment (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Items
Adjustment
Point
Procedure
Check or
Replace
Parts
(A)*
1.85V Supply
Confirmation
CK5
  1. Confirm that the voltage between test point “CK5” and GND is 1.85V ± 0.2V.
  2. Adjust the 1.85V voltage ofCK5 executing command “bandgap XX“(XX is the
value).
IC201,
Q104,
R110
(B)
2.7V Supply
Confirmation
-
  1. Confirm that the voltage between “CK6” and GND is 2.75V ± 0.2V.
IC201,
Q105,R111,
R112,R113
(C)*
BBIC Confirmation
-
  1. BBIC Confirmation (Execute the command “getchk”).
  2. Confirm the returned checksum value.
Connection ofchecksum value and program number is shown below.
IC201,
X100,C203
(D) Charge Control Check &
Charge Current Monitor
Confirmation
-
  1. Apply 6V between JT101(+) and JT102(-) with current limit ofPSU to 200mA.
  2. Confirm that the charge current is ON/OFF.
  3. SW to decrease current limit ofPSU to 100mA.
  4. Confirm that the charge current is stable.
IC201,
Q101,L101,
L102,Q102,
R101,R103,
Q103,R117,
D101,D102,
D103
(E)* Charge Detection (OFF)
Confirmation
-
  1. Stop supplying 6V to JT101(+) and JT102(-).
  2. Execute the command “charge”.
  3. Confirm that the returned value is 0x00 (hex).
IC201,
R118,C111,
L101,L102,
(F)*
Battery Monitor
Confirmation &
Adjustment (Important)
-
  1. Apply 3.5V ± 0.005V DC between BATT(+) and BATT(-).
  2. Execute the command “Backloff” to stabilize the value.
  3. Then, execute the command “readbatt”. The returned value is XX.
  4. Confirm that XX is between 25 and 32.
25
XX
32 (Hex)
(IfXX is out ofrange, change BBIC)
IC201,
R216,R217,
C230
(G) Battery low Confirmation
(Important)
-
  1. Apply 3.5V DC between BATT(+) and BATT(-).
  2. Confirm that there is no flashing of Battery Icon.
  3. Apply 3.3V DC between BATT(+) and BATT(-).
  4. Confirm that there is flashing of Battery.
IC201,
R216,R217,
C230
(H)* BBIC Clock Adjustment
(Important)
SYRI
  1. Apply 3.8V DC between BATT(+) and BATT(-).
  2. Execute the command “conttx”.
  3. Input Command “rdeeprom 00 57 01”, then you can confirm the current value.
  4. Adjust the frequency of SYRI executing the command “setfreq xx (where xx is
the value)” so that the reading ofthe frequency counter is 10.368000MHz ±
10Hz.
IC201,
X100,C203,
C232,L201,
C231,C610
55
KX-TCD566RUS / KX-TCA158RUS
Items
Adjustment
Point
Procedure
Check or
Replace
Parts
(I)*
Transmitted Power
Confirmation
TP601
Remove the Antenna before starting step from 1 to 4.
  1. Configure the DECT tester (CMD60) as follows;
<Setting>
     • 
• 
• 
• 
Test mode: PP
     • 
• 
• 
• 
RFPI: 0102030408
     • 
• 
• 
• 
Traffic Carrier: 5
     • 
• 
• 
• 
Traffic Slot: 4
     • 
• 
• 
• 
Mode: Loopback
     • 
• 
• 
• 
RF LEVEL = -75dBm
  2. Execute the command “regcmd60 01 02 03 04 08".
  3. Initiate connection from DECT tester.
  4. Confirm that the NTP value at TP601 is 20dBm ~ 25dBm.
IC201,
IC601,
IC602,
IC603,
FIL601,
C665,C661,
L618, D601,
C654,L616,
R625,C657,
L615,L614,
C656,L610,
C653,L611,
C650,C646,
R623,C642,
C643,C645,
R633,R634,
R645,L619,
C662,L617,
L605,L603,
R615,L612,
L620
(J)*
Modulation Check and
Adjustment
-
Follow steps 1 to 3 of (I) above.
4.Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data
type Fig 31.
5.Adjust the B-Field Modulation ifrequired to 360kHz/div ~ 380kHz/div.
(Execute the command “Readmod” and “wrtmod xx”, where xx is the value.)
IC201,
IC601
(K)
Frequency Offset
Confirmation
-
Follow steps 1 to 3 of (I) above.
4.Confirm that the frequency Offset is - 50kHz ~ +50kHz.
IC201,
IC601,
IC602,
IC603,
FIL601,
C665,C661,
L618, D601,
C654,L616,
R625,C657,
L615,L614,
C656,L610,
C653,L611,
C650,C646,
R623,C642,
C643,C645,
R633,R634,
R645,L619,
C662,L617,
L605,L603,
R615,L612,
L620,C608,
R603,C609,
C607,R613,
C606,L601,
L602
(L)
Frequency Drift
Confirmation
-
Follow steps 1 to 3 of (I) above.
4.Confirm that the frequency Drift is < ± 30kHz/ms.
IC601,
IC603,
L619,L620,
C662,L617,
C660,R626,
C634,L606,
C633,C632,
L608,C631,
C630,C661,
L618
(M)
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 3 of (I) above.
4.Set DECT tester power to -88dBm.
5.Confirm that the BER is < 1000ppm.
IC1,IC3,
L2,C54,
C60,C61,
C62,C63,
C64,C65,
C66,C67,
C69,C81,
C82,C56,
R58,R55,
R76
(N)
Timing Confirmation
-
Follow steps 1 to 3 of (I) above.
4.Confirm that the Timing accuracy is < ± 1.0ppm.
IC601,
R631,C649,
IC201
56
KX-TCD566RUS / KX-TCA158RUS
Page of 111
Display

Click on the first or last page to see other KX-TCD566RUS / KX-TCA158RUS service manuals if exist.