14.2.2. Flow Solder Side View
Frequency
Counter
(E)
Digital
Volt Meter
(C)
(P)
To PC (JIG)
Digital
Volt Meter
Digital Volt Meter
(D) (E) (F) (G) 
(H) (N) (O)
(A)
Digital
Volt Meter
(B)
12
/2W
TP1
TP84
TP97
TP82
TP187
TP91
TP188
TP101
TP89
TP2
1
3
5
2
4
6
TP5
TP90
TP50
TP45
TP39
TP3
TP40
TP85
J101
J103
J104
J102
J105
PbF
+2.65V
SD
A
SCL
GND
VBA
CK
CHARGE
CHARGE
DTMF
tester
Tel
Simulator
(F) (N) (O)
(G)
Note:
(A) - (P) is refered to ADJUSTMENTS (BASE UNIT AND CHARGER UNIT) (P.44)
KX
-T
CD4
50RUM
/
K
X
-A1
45RUM
/
K
X
-T
C
D450R
UT
/
K
X
-A145R
UT
49
14.3. Adjustment (Charger Unit)
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(A)
Charging Check
-
 1. 
Connect Charge Contact 12
/2W register between charge+ and charge-.
 2. 
Measure and confirm voltage across the regigster is 2.7V ± 0.2V.
D1,R1,R2
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.50).
14.4. Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
14.4.1. Flow Solder Side View
PbF
R1
R2
TP4
TP1
TP2
TP3
Digital Volt Meter
12
/2W
(A)
Note:
(A) is refered to ADJUSTMENTS (BASE UNIT AND CHARGER UNIT) (P.44)
50
KX-TCD450RUM / KX-A145RUM / KX-TCD450R UT / KX-A145RUT
15 ADJUSTMENTS (HANDSET)
If your unit have below symptoms, adjust or confirm each item using remedy column from the table.
Symptom
Remedy*
The movement of Battery Low indicator is wrong.
Make confirmation in item (A), (B), (E), (F)
The handset does not respond to a call from base unit.
Make adjustments in item (A), (B), (G), (I)~(M)
The handset does not transmit or the transmit frequency is off.
Make adjustments in item (A), (B), (G)~(J), (L)
The transmit frequency is off.
Make confirmation in item (A), (B), (G)~(J), (L)
The transmit power output is low, and the operating distance between base unit and handset is
less than normal.
Make confirmation in item (H), (K)
The reception sensitivity of base unit is low with noise.
Make confirmation in item (K)
Does not link between base unit and handset.
Make confirmation in item (A), (B), (G)~(M)
The reception level is high or low.
Make adjustments in item (N)
The transmit level is high or low.
Make adjustments in item (O)
* : Refer to Adjustment (P.51)
15.1. Adjustment
Please follow the items below when BBIC or EEPROM or FLASH ROM are replaced.
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(A)
4.0V Supply
Confirmation
-
 1. 
Confirm that the consumption current is < 200mA , that is, there is no short
circuit.
 2. 
Confirm that the voltage between test point “+4V” and GND is 4.1V ± 0.2V.
IC1,F1,R14,
R15,C53,C1,
L1,D16,C4,
C5,C9,Q3,
R11,R16,R12,
C11,X1,C6,
C7,C70,IC10,
C401,C402,
C403,IC4,
C405,C408,
C409,C65,
C12,D20
(B)
BBIC Confirmation
-
 1. 
BBIC Confirmation (Execute the command "getchk").
 2. 
Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1,X1,C6,
C7,C70
(C) Charge Control Check &
Charge Current Monitor
Confirmation
-
 1. 
Apply 6V between TP5(+) and TP6(-) with current limit of PSU to 200mA.
 2. 
Confirm that the charge current is ON/OFF.
 3. 
SW to decrease current limit of PSU to 100mA.
 4. 
Confirm that the charge current is stable.
IC1,C52,Q7,
Q8,R51,R12,
C11,F1,R14,
R15,C53,C1
(D)* Charge Detection (OFF)
Confirmation
-
 1. 
Stop supplying 6V to TP5(+) and TP6(-).
 2. 
Execute the command "charge".
 3. 
Confirm that the returned value is 0x00 (hex).
IC1,C52,Q7,
Q8,R51,R12,
C11,F1,R14,
R15,C53,C1
(E)*
Battery Monitor
Confirmation
-
 1. 
Apply 2.3V ± 0.005V between TP3(+) and TP4(-).
 2. 
Execute the command "readbatt".
 3. 
Confirm:
95 < returned value < A0 (Hex)
 4. 
Execute the command "WRTBAT2 XX".
IC1,C52,Q7,
Q8,R51,R12,
C11,F1,R14,
R15,C53,C1
(F) Battery low Confirmation
-
 1. 
Apply 2.40V between TP3(+) and TP4(-).
 2. 
Confirm that there is no Speaker sound (Battery low alarm).
 3. 
Apply 2.20V between TP3(+) and TP4(-).
 4. 
Confirm that there is Speaker sound (Battery low alarm).
IC1,F1,R14,
R15,R12,C11,
C1,C53,IC4,
R2,R17,R18,
R31,C8,C10,
C23,C24,C36,
C66,C67,C68,
D19
(G)* BBIC Clock Adjusment
MCLK
 1. 
Execute the command "conttx".
 2. 
Adjust the frequency of MCLK executing thecommand "setfreq 00 xx (where xx
is the value)" so that the reading of the frequency counter is 10.368000MHz ±
3MHz.
IC1,X1,C6,
C7,C70,IC10,
L5,C111
51
KX-TCD450RUM / KX-A145RUM / KX-TCD450R UT / KX-A145RUT
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(H)*
Transmitted Power
Confirmation
TP15
Remove the Antenna before starting step from 1 to 5.
 1. 
Configure the DECT tester(CMD60) as follows;
<Setting>
    
·
    
Test mode: PP
    
·
    
RFPI: 0102030405
    
·
    
Traffic Channel: 5
    
·
    
Traffic Slot: 4
    
·
    
Mode: Loopback
 2. 
Execute the command "testmode".
 3. 
Execute the command "regcmd60"
 4. 
Initiate connection from DECT tester.
 5. 
Confirm that the NTP value at A201 (TP15) is 20dBm ~ 25dBm
IC1,IC10,
R410,L5,
C111,C422,
C423,C405,
R411,C408,
C409,C401,
C402,C403
(I)
Modulatoin Check and
Adjusment
TP15
Follow steps 1 to 4 of (H) above.
5.Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data
type Fig31.
6.Adjust the B-Field Modulation if required. (Execute the command "Readmod"
and "Writemod xx", where xx is the value.)
IC1,IC10,
R410,L5,
C111,C422,
C423,C405,
R411,C408,
C409,C401,
C402,C403
(J)
Frequency Offset
Confirmation
-
Follow steps 1 to 4 of (H) above.
5.Confirm that the frequency offset is < ± 40kHz.
IC1,IC10,
R410,L5,
C111,C422,
C423,C405,
R411,C408,
C409,C401,
C402,C403
(K)
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 4 of (H) above.
5.Set DECT tester power to -88dBm.
6.Confirm that the BER is < 1000ppm.
IC1,IC10,
R410,L5,
C111,C422,
C423,C405,
R411,C408,
C409,C401,
C402,C403
(L)
Timing Confirmation
-
Follow steps 1 to 4 of (H) above.
5.Confirm that the Timing accuracy is < ± 10ppm.
IC1,IC10,
R410,L5,
C111,C422,
C423,C405,
R411,C408,
C409,C401,
C402,C403
(M)*
RSSI Level
Confirmation
-
Follow steps 1 to 4 of (H) above.
5.Set DECT tester power to -88dBm.
6.Execute the command "readrssi"
7.Confirm: 23 < returned value < 45 (hex).
IC1,IC10,
R410,L5,
C111,C422,
C423,C405,
R411,C408,
C409,C401,
C402,C403