1 ABOUT LEAD FREE SOLDER (PbF: Pb free)
4
1.1. Suggested PbF Solder
4
1.2. How to Recognize that Pb Free Solder is Used
5
2 FOR SERVICE TECHNICIANS
6
3 CAUTION
6
4 BATTERY
7
4.1. Battery Installation
7
4.2. Battery Charge
7
4.3. Battery Life
8
4.4. Battery Replacement
8
5 LOCATION OF CONTROLS
9
5.1. Base Unit
9
5.2. Handset
9
6 SETTINGS
10
6.1. Connections
11
6.2. Guide to Settings
12
6.3. Ringer Volume
14
6.4. Night Mode
15
6.5. PIN Code
16
6.6. Reset
17
6.7. Key Lock
18
6.8. R Button (to Use the Recall Feature)
18
6.9. Pause Button for PBX/Long Distance Service Users
18
6.10. Setting Call Restriction
18
6.11. Turning Call BAR On/Off (Call Prohibition)
19
6.12. Changing the Display Language
19
6.13. Changing the Recall Time
19
6.14. Setting Dialling Mode (Tone/Pulse)
19
6.15. ARS (Automatic Route Selection)
20
7 DISPLAY
22
7.1. Display Icons
22
7.2. ABH and Caller ID Display
22
8 OPERATIONS
24
8.1. Turning the Power On/Off
24
8.2. Setting the Date and Time
24
8.3. Redialling
24
8.4. Calling Code
25
8.5. Voice ABH
25
8.6. Phonebook
26
8.7. Voice Mail Service
29
8.8. Registering a Handset to a Base Unit
30
8.9. Selecting a Base Unit
31
9 TROUBLESHOOTING
32
10 DISASSEMBLY INSTRUCTIONS
34
10.1. Base Unit
34
10.2. Handset
35
10.3. Charger Unit
36
11 HOW TO REPLACE THE HANDSET LCD
37
12 TROUBLESHOOTING FLOWCHART
38
12.1. Check Power
39
12.2. Check Battery Charge
40
12.3. Check Link
41
12.4. Check Handset Transmission
45
12.5. Check Handset Reception
45
12.6. Check Caller ID
45
12.7. Bell Reception
46
13 TROUBLESHOOTING BY SYMPTOM (BASE UNIT AND
CHARGER UNIT)
47
13.1. Check Point (Base Unit)
47
13.2. The Setting Method ofJIG (Base Unit)
51
13.3. Adjustment Standard (Base Unit)
52
13.4. Check Point (Charger Unit)
53
13.5. Adjustment Standard (Charger Unit)
53
14 TROUBLESHOOTING BY SYMPTOM (HANDSET)
54
14.1. Check Point (Handset)
54
14.2. Troubleshooting for Speakerphone
57
14.3. The Setting Method ofJIG (Handset)
58
14.4. Adjustment Standard (Handset)
59
15 THINGS TO DO AFTER REPLACING IC
60
15.1. Base Unit
60
15.2. Handset
60
16 RF SPECIFICATION
61
16.1. Base Unit
61
16.2. Handset
61
Note:
Because CONTENTS 4 to 9 are the extracts from the Operating Instructions of this model, they are subject to change without
notice. Please refer to the original Operating Instructions for further information.
notice. Please refer to the original Operating Instructions for further information.
CONTENTS
Page
Page
2
KX-TCD215UA / KX-TCD217U A / KX-TCA121UA
17 HOW TO CHECK THE HANDSET SPEAKER OR RECEIVER 62
18 FREQUENCY TABLE (MHz)
62
19 BLOCK DIAGRAM (BASE UNIT)
63
20 CIRCUIT OPERATION (BASE UNIT)
64
20.1. Outline
64
20.2. Power Supply Circuit
65
20.3. Telephone Line Interface
66
20.4. Transmitter/Receiver
66
20.5. Pulse Dialling
66
21 BLOCK DIAGRAM (HANDSET)
67
22 CIRCUIT OPERATION (HANDSET)
68
22.1. Outline
68
22.2. Power Supply Circuit/Reset Circuit
68
22.3. Charge Circuit
68
22.4. Battery Low/Power Down Detector
68
22.5. Speakerphone
68
23 CIRCUIT OPERATION (CHARGER UNIT)
69
23.1. Power Supply Circuit
69
24 SIGNAL ROUTE
70
25 CPU DATA (BASE UNIT)
71
25.1. IC8 (BBIC)
71
26 CPU DATA (HANDSET)
73
26.1. IC1 (BBIC)
73
27 ENGINEERING MODE
75
27.1. Base Unit
75
27.2. Handset
78
28 EEPROM LAYOUT (BASE UNIT)
80
28.1. Scope
80
28.2. Introduction
80
28.3. EEPROM Layout
80
29 EEPROM LAYOUT (HANDSET)
85
29.1. Scope
85
29.2. Introduction
85
29.3. EEPROM contents
85
30 HOW TO REPLACE THE FLAT PACKAGE IC
88
30.1. PREPARATION
88
30.2. FLAT PACKAGE IC REMOVAL PROCEDURE
88
30.3. FLAT PACKAGE IC INSTALLATION PROCEDURE
89
30.4. BRIDGE MODIFICATION PROCEDURE
89
31 CABINET AND ELECTRICAL PARTS (BASE UNIT)
90
32 CABINET AND ELECTRICAL PARTS (HANDSET)
91
33 CABINET AND ELECTRICAL PARTS (CHARGER UNIT)
92
34 ACCESSORIES AND PACKING MATERIALS
93
34.1. KX-TCD215UAF/UAS/UAT
93
34.2. KX-TCD217UAS/UAT
94
34.3. KX-TCA121UAF/UAS/UAT
95
35 TERMINAL GUIDE OF THE ICs, TRANSISTORS AND DIODES
96
35.1. Base Unit
96
35.2. Handset
96
35.3. Charger Unit
96
36 REPLACEMENT PARTS LIST
97
36.1. Base Unit
97
36.2. Handset
99
36.3. Charger Unit
100
36.4. Accessories and Packing Materials
101
36.5. Fixtures and Tools
101
37 FOR SCHEMATIC DIAGRAM
103
37.1. Base Unit (SCHEMATIC DIAGRAM (BASE UNIT))
103
37.2. Handset (SCHEMATIC DIAGRAM (HANDSET))
103
37.3. Charger Unit (SCHEMATIC DIAGRAM (CHARGER UNIT))
103
38 SCHEMATIC DIAGRAM (BASE UNIT)
104
39 SCHEMATIC DIAGRAM (HANDSET)
106
40 SCHEMATIC DIAGRAM (CHARGER UNIT)
108
41 CIRCUIT BOARD (BASE UNIT)
109
41.1. Component View
109
41.2. Flow Solder Side View
110
42 CIRCUIT BOARD (HANDSET)
111
42.1. Component View
111
42.2. Flow Solder Side View
112
43 CIRCUIT BOARD (CHARGER UNIT)
113
43.1. Component View
113
43.2. Flow Solder Side View
113
3
KX-TCD215UA / KX-TCD217U A / KX-TCA121UA
1 ABOUT LEAD FREE SOLDER (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that
contains lead.
contains lead.
We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn),
Silver (Ag), and Copper (Cu).
Silver (Ag), and Copper (Cu).
This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair
work we suggest using the same type ofsolder although, with some precautions, standard Pb solder can also be used.
work we suggest using the same type ofsolder although, with some precautions, standard Pb solder can also be used.
Caution
•
•
•
•
PbF solder has a melting point that is 50°F ~ 70°F (30°C ~ 40°C) higher than Pb solder. Please use a soldering iron with
temperature control and adjust it to 700°F ± 20°F (370°C ± 10°C). In case ofusing high temperature soldering iron, please
be careful not to heat too long.
temperature control and adjust it to 700°F ± 20°F (370°C ± 10°C). In case ofusing high temperature soldering iron, please
be careful not to heat too long.
•
•
•
•
PbF solder will tend to splash ifit is heated much higher than its melting point, approximately 1100°F (600°C).
•
•
•
•
Ifyou must use Pb solder on a PCB manufactured using PbF solder, remove as much ofthe original PbF solder as possible
and be sure that any remaining is melted prior to applying the Pb solder.
and be sure that any remaining is melted prior to applying the Pb solder.
•
•
•
•
When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the
opposite side (See the figure below).
opposite side (See the figure below).
1.1.
Suggested PbF Solder
There are several types ofPbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper
(Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the
manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other
materials.
(Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the
manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other
materials.
The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3mm, 0.6mm and 1.0mm.
4
KX-TCD215UA / KX-TCD217U A / KX-TCA121UA