1-3
1.2
DIAGNOSTICS OF MAJOR PC BOARDS
1.2.1
Diagnosing the MAIN and DECK TERMINAL Boards
(1) Remove the top cover and bottom cover as described in
sections 1.1.3 and 1.1.5.
(2) As described in section 1.1.7, disassemble the unit as shown
in Figs. 1-1-7 (b) and (c) before proceeding to the diagnos-
tics of these PC boards.
1.2.2
Diagnosing the FRONT 1 and FRONT 2 Boards
(1) Remove the top cover and front panel assembly as described
in sections 1.1.3 and 1.1.4.
(2) Remove the FRONT 1 and FRONT 2 boards by pushing the 2
hooks 
Ó
 and 1 hook 
Ô
 gently in the direction of arrows g,
then remove the FRONT 1 and FRONT 2 boards and diag-
nose them.
(4) Unplug the connectors 
Ç
Î
´
 and 
Ï
.
Fig. 1-1-7(c)
(5) Unplug the connector 
˝
.
(6) Remove the 2 screws 
S8
 and 2 screws 
S9
, then remove
the mechanism assembly in the upward direction.
Fig. 1-1-7(d)
Fig. 1-2-3(a)
(1) Remove the top cover as described in section 1.1.3.
(2) Remove the 2 screws 
S10
.
CAUTION
The supply voltage is input directly into the SW REG.
board ass’y. Be careful not to get an electric shock while
diagnosing and servicing.
1.2.3
Diagnosing the SW REG. Board
Fig. 1-2-2
Ç
Î
Ï
´
DECK TERMINAL board
MAIN board
˝
S8
S9
Ô
Ó
FRONT 1 board
FRONT 2 board
S10
1-4
Ò
Â
S14
Fig. 1-2-3(b)
(3) Remove the 3 screws 
S11
, remove the SW REG. board in
an upward direction and diagnose it.
S11
SW REG. board
1.2.4
Diagnosing the P/R Board
(1) Remove the top cover  as described in section 1.1.3.
(2) Remove the 4 screws 
S12
 and 2 screws 
S13
.
CAUTION
• Read the notes on the lithium backup battery in sec-
tion 1.4.
Fig. 1-2-5
1.2.5
Replacing the Lithium Battery
(1) Tilt the MAIN board as described in section 1.1.7 (1), (2) and
(3).
(2) Remove the lithium battery by pushing it lightly in the direc-
tion of the arrow e.
Fig. 1-2-4(b)
(3) Remove the wire from the clamp 
, remove the screw 
S14
,
then remove the shielded case (P/R) 
Ò
 in an upward direc-
tion.
(4) Remove the shielded case (REG) 
Â
 in an upward direction
and diagnose the P/R board.
Fig. 1-2-4(a)
S13
S12
Lithium battery
1-5
1.3
SERVICE MENU
1.3.1
Menu Configuration and Operation Procedure
The SERVICE MENU mode is used during servicing. It is configured as shown below.
Power ON
Press the [STOP], [PAUSE] and
[MENU] buttons simultaneously.
FUNCTION
HOUR METER
EMERGENCY
HISTORY
MECHA
CHECK MODE
OPERATION
CHECK MODE
SERVO
ADJUST MODE
Caution: There should be no cassette loaded in the unit.
Press the [menu] button to return to
the EMERGENCY HISTORY screen.
Used to check the history of warnings and 
emergencies related to the mechanism.
From this screen, press the [SET –] or [SET+] 
button to view the mechanism mode and sensor 
status information at the moment a warning 
condition occurred.
See sections 1.3.4 and 1.3.5.
This is the initial screen of the SERVICE MENU.
Select a menu item with the [SHIFT 
] and [SHIFT 
] buttons and go to a mode in the lower band by pressing 
the [SET -] or [SET +] button.
Pressing the [MENU] button cancels the SERVICE MENU mode.
The on-screen display is not provided when EVR ADJUST is selected. The information is displayed in the 
front panel FDP.
Used to check the ROM version from the initial screen.
Used to disable the warning detection and initialize the menu switch 
settings to the factory setting.
See section 1.3.2.
Used to check the hour meters.
See section 1.3.3.
Used for servo adjustments.
See section 3.2.
Used to diagnose the mechanism operating sensors without using a 
measuring tool.
See section 1.3.5
Used to check the operation switch modes.
Pressing one of the buttons displayed in this screen changes the displayed 
name of the pressed button to ">".
    FUNCTION
    HOUR METER
    EMERGENCY HISTORY
    MECHA CHECK MODE
    OPERATION CHECK MODE
    SERVO ADJUST
    EVR ADJUST
    ROM VER.
[SERVICE MENU]
1. WARNING ENABLE
2. MENU INITIALIZE
[FUNCTION]
ON
OFF
1. DRUM ON
2. OPERATE ON
3. CAPSTAN ON
4. TOTAL DRUM ON
5. LOADING COUNT
6. EJECT COUNT
7. BATTERY
[HOUR METER]
000000H
000000H
000000H
000000H
000000
000000
000000
1. E–04:DRUM ERROR
2. E–06:CAPSTAN ERROR
3. E–05:TU REEL ERROR
4. E–––:
[EMERGENCY HISTORY]
99–02–02  02:11
99–01–02  02:11
98–12–21  02:11
(MODE) EJECT
(ENCD) HHLL
(SAFE) ON
(BGIN) ON
(CAPN) OFF
(SPFG) L
(SP. D) 070
(REMN) 000
[MECHA CHECK MODE]
→ NOCAS
(REF.) HHLL
(CASS) OFF
(END) ON
(F/R) FWD
(TUFG)  H
(TU. D) 070
(MODE) EJECT
(ENCD) HHLL
(SAFE) ON
(BGIN) ON
(CAPN) OFF
(SPFG) L
(SP. D) 070
(REMN) 000
[MECHA CHECK MODE]
→ NOCAS
(REF.) HHLL
(CASS) OFF
(END) ON
(F/R) FWD
(TUFG)  H
(TU. D) 070
REC
REW
PLAY
TRACKING–
V. LOCK–
TIMER
LOCK
SHIFT
SET+
[OPERATION CHECK MODE]
STOP
REVERSE
SEARCH
CNTRST
SHIFT
EJECT
REC CHK
PAUSE
FF
TRACKING+
V. LOCK+
DISPLAY
RST/CAN
SET –
OPERATE
      24H SLOW TRACKING
        3HVLK (0F)
    L12HVLK (00)
    L24HVLK (02)
      48H TL MOVE
  
      48HSKW (1D) 
    L12HSKW (70)
    L24HSKW (4C)
    SW. POINT
[SERVO ADJUST MODE]
(12)
(22)
(5A)
1-6
1.3.2
Function
1. WARNING ENABLE
[ON]
Enables warning detection.
OFF
Disables warning detection.
2. MENU INITIALIZE
Initializes the service menu switch setting to the factory setting.
Pressing the [STOP] and [RESET/CANCEL] buttons simultaneously when the
cursor is located on “MENU INITIALIZE” resets the menu switch setting to
the factory setting and changes the display from OFF to ON.
Table 1-3-3
Item
Setting
Description
Item
Display
Description
1. DRUM ON
dh
Displays the drum rotation time.
2. OPERATE ON
Ph
Displays the operating time.
3. CAPSTAN ON
Ch
Displays the capstan rotation time.
4. TOTAL DRUM ON
td
Displays the total drum rotation time.
5. LOADING COUNT
Lc
Displays the number of loading operations.
6. EJECT COUNT
Ec
Displays the number of ejection operations.
7. BATTERY
bt
Allows writing of the current date data. Press the [RESET/CANCEL], [SET +] and
[SET -] buttons simultaneously while the cursor is located on “BATTERY” to write
the current date. This must be executed after the lithium battery replacement.
Table 1-3-4
1.3.3
Hour meter
This screen is used to check the hour meters.
1.3.4
Emergency history
This screen is used to check the history of warning emergencies related to the mechanism. The emergency history is written in the
EEPROM (IC607 on the MAIN board) and records the history of the latest 4 emergencies.
Press the [STOP], [PAUSE] and [CNT RESET] buttons simultaneously while the emergency history is displayed to reset the history.
1. DRUM ON
2. OPERATE ON
3. CAPSTAN ON
4. TOTAL DRUM ON
5. LOADING COUNT
6. EJECT COUNT
7. BATTERY
[HOUR METER]
000000H
000000H
000000H
000000H
000000
000000
000000
1. E–07:EJECT ERROR
2. E–01:LOADING ERROR
3. E–––:
4. E–––: 
[EMERGENCY HISTORY]
98–07–24  12:40
98–07–20  08:01
Latest emergency
Error code
Year, month, day, hour and
minute of occurrence
Warning details
Last but one emergency
Last but two emergency
Last but three emergency
[ ] indicates the factory setting.