ADJ-14
SECTION 3 ADJUSTMENTS
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
 
  "Check: OK"  -> Click the [OK] button and step to the next.
  "Check: NG"  -> Check the setting in step 4.
5. Select the Microcomputer's firmware file,Click the [load] button.
6. Select the new firmware, and click [Open] button.
*  The firmware combines 
the Main, Sub and Net-
work firmware. 
*   DIGITAL LINK  can be 
updated  via  serial con-
nection only.
Display example of Serial terminal connection
Display example of LAN terminal connection
ADJ-15
SECTION 3 ADJUSTMENTS
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
7. After loading the firmware, a checkmark and path name to the firmware and the version will be displayed on the window.
  Click [Update] button to start updating of the firmware if the all information is right .
8. Click [OK] button to start updating if the software version is right. 
9.  During updating, the message "Now updating....." appears and all the LED are blinking. After finishing updating, the mes-
sage "Waiting for Projector reboot..." appears and the projector sets into standby mode when turn it on again. (The LED 
stops blinking.)
* Don't operate the projector  
  during updating.
* Never disconnect the  
  AC cord during updating.
*  Please disconnect the AC cord then plug it, if the message  "Waiting for 
Projector reboot" appears or the pop-up OSD disappears and the LED  
don't  blink after waiting for about 1 minute . 
ADJ-16
SECTION 3 ADJUSTMENTS
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
10.  When the tool detects that the projector has rebooted, the conformation window will appear. Click the [OK] button to close 
the window.
    * If the version of the firmware is the same, its updating will be skipped.
11 Click the [EXIT] button to quit the application.
12.  Turn the projector on and display the [EXTRA OPTION] menu. Confirm that the version of the Main CPU is updated cor-
rectly on the [SELF CHECK] item.