Panasonic PT-TX301RU / PT-TX301RE / PT-TX301REA / PT-TW331RU / PT-TW331RE / PT-TW331REA (serv.man2) Service Manual ▷ View online
PT-TW331R / PT-TX301R series
3-17
14
Lamp Fail
Count the lamp ignite fail times
V
15
CW Fail
Count the color wheel fail times
V
16
Spoke Test
To select some test pattern for simple test
V
V
17
Burn in Test
Choose this option and press enter key getting
into Burn in Test menu
into Burn in Test menu
V
V
18
Color Wheel Index
Choose “CW index ” to adjust color wheel index
V
V
19
ADC Calibration
To adjust the white and black signal level
V
V
20
SNID Read
This is an inactive item for Panasonic models
V
21
Thermal Detect
Enable or disable thermal detect function
V
22
Waveform ID
Show the waveform’s ID
V
23
Debug Message
On or off debug message
V
24
Direct Power on
Select “on“,the unit will power on automatically
when it turns off abnomally,select “off“ ,the func-
tion will be disabled.
when it turns off abnomally,select “off“ ,the func-
tion will be disabled.
V
V
25
Factory Fan RPM
Shows the FAN rotate value
V
V
26
Factory Reset
Reset the projector’s value to default
V
V
27
Internal Bus Log
Record the I2C bus error status
28
Exit
Leave Service Menu
V
V
Note:The “Whereused “ does not mark just for RD use.
Item
Description
Explanation
Whereused
For Service
For Factory
1
MCU M12
Shows the present MCU FW version
V
V
2
LAN-L13H
Shows the present LAN FW version
V
V
3
PT-TW331R
Indicate the model name
V
V
4
C09
Indicate the present SYS FW version is B04
V
V
5
< Aug 30 2013-
18:24>
Date and time of build code
V
6
Lamp Hour-Full
Shows working hours of the projector in full
mode
mode
V
V
7
Lamp Hour-ECO
Shows working hours of the projector in eco
mode
mode
V
V
8
Operating Hour
Shows operating hours of the projector
V
V
9
Lamp On/Off
Counter
Shows the times of lamp on or lamp off
V
10
Lamp Voltage /
Max
Shows Lamp current voltage and the max
voltage
voltage
V
11
UART Response
Count the lamp driver failure times
V
12
Over Temp
Count the over temperature times
V
13
Fan Lock
Count the fan lock times
V
PT-TW331R / PT-TX301R series
3-18
PT-TW331R / PT-TX301R series
4-1
Chapter 4
Function Test & Alignment Procedure
4-1 Run In Test
- Temperature: 15°C~35°C
- Circumstance brightness: Normal environment
- Circumstance brightness: Normal environment
- Screen size: 60''
- Display mode: ECO mode
After repairing each unit,a Ru
n-in test is necessary (refer to the below table).
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shutdown
6 hours
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in operating time is 4 hours.
You have to set the lamp on for 60 min. and lamp off for 10 min for 4 cycles.
Press Power >Left >Right >Menu buttons sequentially on remote controller or on the top panel
to get into service mode.
Choose Burn-In Test >Menu
Lamp On
to get into service mode.
Choose Burn-In Test >Menu
Lamp On
Press right key to adjust the time (60)
Lamp Off
Press right key to adjust the time (10)
Set burn in cycle
Press right key to adjust the cycle
After setting up the time,choose “
Enter Burn-In Mode” and press "Menu".
The projector will start testing.
PT-TW331R / PT-TX301R series
4-2
4-2 Test Inspection Procedure
1. Check Points
Check item
Check point
Firmware version
All firmware version must be the latest version
Cosmetic
Cosmetic can not be broken
Logo
Missing logo, missing prints and blurry prints are
unacceptable
unacceptable
Lamp cover
It should be locked in the correct place.
Keypad
All keypad buttons must operate smoothly
2. OSD Reset
After final QC step, we have to erase all saved change again and restore the OSD
default setting.The following actions will allow you to erase all end-users' settings and
restore the default settings:
default setting.The following actions will allow you to erase all end-users' settings and
restore the default settings:
(1) Please enter OSD menu.
(2) Choose "Settings" and then execute "Reset" function