Panasonic PT-TW342 / PT-TX402 / PT-TX312 (serv.man4) Service Manual ▷ View online
-37-
Electrical adjustment
MAIN board
Test points and locations
FAN_B1
FAN_A1
FAN_C1
-38-
Electrical adjustment
Service adjustment data
Group/
item
Item Name
Function
Initial
Range
Note
Group
102
102
Option
0 Offset
Offset (unit 1/64 degree) indicates
0
-1056 ~
1056
1 Offset Switch
"0: Offset indicates (normal)
1: Offset indicates (when the calibration is
wrong)"
1: Offset indicates (when the calibration is
wrong)"
0
0-1
2 Debug Mode
0: none
0
0-1
3 Service Calibration
1: angle (0.5 degree), AD value (1/1000V)
indicates, RS232C output
indicates, RS232C output
0
0-10
4 Lock Count
"If in No4 value, enters the No4 threshold
value without keystone offset correction. "
value without keystone offset correction. "
5
1-255
5 Delta Vert Result
"If in No4 value, enters the No5 threshold
value without keystone offset correction. "
value without keystone offset correction. "
64
1-255
6 Angle 1 Count
No6 value x No7 value = calculation number
1
1-10
7 Angle 2 Count
No6 value x No7 value = calculation number
5
1-10
8 Blind Sector 1
"Blind sector 1 (unit 1/64 degree)
from 0 degree center projector incline and
convert the threshold to 0 degree."
from 0 degree center projector incline and
convert the threshold to 0 degree."
160
0-1024
9 Blind Sector 2
"Blind sector 2 (unit 1/64 degree) exceeds
blind sector 1. Change it to No10 value in
the threshold value (blind sector 2 + blind
sector 1)"
blind sector 1. Change it to No10 value in
the threshold value (blind sector 2 + blind
sector 1)"
32
0-1024
10 Blind Sector Bias
"Change the value when the bias
(unit 1/64 degree) blind sector 2 (No9) is
included in the blind sector. "
(unit 1/64 degree) blind sector 2 (No9) is
included in the blind sector. "
61
0-1024
Group
200
200
Option
1 Baud rate setting
0: 19200 bps, 1: 9600 bps
0
0-1
RS232C baud rate change
30 Lamp life test enable
0:Disable 1:Enable, lamp service life test
only
only
0
0-1
31 Lamp On time (for life test)
Startup time (minute) setting
2
1-720
32 Lamp Off time (for life test)
Off time (minute) setting
0
1-720
61
Remote control code
switching
switching
data=0 indicates panasonic format, data=1
indicates sanyo format
indicates sanyo format
0
0-1
80 Shipping and destination
0=worldwide, 1=JPN, 2: Education 3:
Business
Business
0
0-3
81 Capture
0: Disable 1: Enable
1
0-1
Group
220
220
Error Log
(See Error Log section for the details)
0 Latest Error Log
0
1 Second Error Log
0
2 Third Error Log
0
3 fourth Error Log
0
4 fifth Error Log
0
5 sixth Error Log
0
6 seventh Error Log
0
7 eighth Error Log
0
8 ninth Error Log
0
9 tenth Error Log
0
10 eleventh Error Log
0
11 twelfth Error Log
0
12 thirteenth Error Log
0
13 fourteenth Error Log
0
14 fifteenth Error Log
0
15 sixteenth Error Log
0
16 seventeenth Error Log
0
17 eighteenth Error Log
0
18 nineteenth Error Log
0
19 twentieth Error Log
0
20 twenty-first Error Log
0
21 twenty-second Error Log
0
22 twenty-third Error Log
0
23 twenty-fourth Error Log
0
24 twenty-fifth Error Log
0
25 twenty-sixth Error Log
0
26 twenty-seventh Error Log
0
27 twenty-eighth Error Log
0
28 twenty-ninth Error Log
0
29 thirtieth Error Log
0
30 thirty-first Error Log
0
31 thirty-second Error Log
0
32 thirty-third Error Log
0
33 thirty-fourth Error Log
0
34 thirty-fifth Error Log
0
35 thirty-sixth Error Log
0
36 thirty-seventh Error Log
0
37 thirty-eighth Error Log
0
38 thirty-ninth Error Log
0
39 fortieth Error Log
0
-39-
Electrical adjustment
Group/
item
Item Name
Function
Initial
Range
Note
40 forty-first Error Log
0
41 forty-second Error Log
0
42 forty-third Error Log
0
43 forty-fourth Error Log
0
44 forty-fifth Error Log
0
45 forty-sixth Error Log
0
46 forty-seventh Error Log
0
47 forty-eighth Error Log
0
48 forty-ninth Error Log
0
49 fiftieth Error Log
0
Group
290
290
L/R Panel
0 Panel Type Indication
0: L Panel, 20: R Panel
0
0-20
1 Setup Panel Type
0 Set when L Type Optical Block is used.
20 Set when R Type Optical Block used.
10
0-20
-40-
Electrical adjustment
EEPROM data transfer
1. Required equipment
1. PC : Use for EEPROM data transfer
2. Communication cable : D-sub 9pin (male/female RS-232C straight)
3. Software : Data Backup Tool Package data
(Download from the projector service homepage.)
2. Communication cable : D-sub 9pin (male/female RS-232C straight)
3. Software : Data Backup Tool Package data
(Download from the projector service homepage.)
2. Preparation
1. Move the folder "DataBackup" to the top directory of the C drive on your PC. There are files in the folder as
shown below .
- PJ data Read Tool Ver2.3.exe
Data read out software
- PJ data Write Tool Ver2.3.exe
Data write down software
- COMCTL32.OCX
Windows OCX file
- MSCOMM32.OCX
Windows OCX file
- setting.ini
Setting file
2. Connect the serial terminal of projector and PC
with an RS-232C cable.
[Note] Setup the projector not to enter the standby
mode or shutdown mode during the working.
Communication cable (straight)
D-Sub 9p (Male)
D-Sub 9p (Female)
Projector Connection terminals
Computer
3. Backup the EEPROM data (before re-
placing A-P.C.Board)
1. Double click the icon of software [PJ data Read
Tool Ver2.3.exe] in the folder of "DataBackup". The
control window will appear.
control window will appear.
2. Input 9-digit number on the text box as the file
name. e.g. serial number. This file will be stored in
"DataBackup" folder.
"DataBackup" folder.
3. Connect the AC cord and turn the projector on.
4. Select the available COM port number and then press
4. Select the available COM port number and then press
the button to start reading-out the EEPROM data
from the projector and stored it in your PC.
from the projector and stored it in your PC.
5. After completing the reading out, "OK" will be appear
on the window.
[Note]
If "NG" appears, should delete a created file and then
If "NG" appears, should delete a created file and then
take step 4 again. Do not overwrite the data into a
created file.
created file.
Data file name
Click on the first or last page to see other PT-TW342 / PT-TX402 / PT-TX312 (serv.man4) service manuals if exist.