DOWNLOAD Panasonic PT-RZ970 / PT-RW930 / PT-RX110 (serv.man6) Service Manual ↓ Size: 35.32 MB | Pages: 125 in PDF or view online for FREE

Model
PT-RZ970 PT-RW930 PT-RX110 (serv.man6)
Pages
125
Size
35.32 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / 1-CHIP DLP BASED PROJECTOR
File
pt-rz970-pt-rw930-pt-rx110-sm6.pdf
Date

Panasonic PT-RZ970 / PT-RW930 / PT-RX110 (serv.man6) Service Manual ▷ View online

INF-25
SECTION 1 SERVICE INFORMATION
< RZ970/RW930/RX110 >
5. 1. 2. Light source indicators
  • If a problem occurs inside the projector, the light source indicators <LIGHT1>/<LIGHT2> will inform you by lighting or blink-
ing.
Indicator status
Status
Solution
Lighting in red
Some of the elements of the light 
source are defective and the light 
output has decreased.
f
  Turn the <MAIN POWER> switch to <OFF> , and turn on the power again.
Blinking in red
(1 time)
The light source is turned off since the 
projection lens cannot be detected.
f
  Turn off the power and mount the projection lens again. 
f
  Turn the <MAIN POWER> switch to <OFF>, and turn on thepower again. 
Blinking in red
(2 times)
The light source does not light up, 
or the light source turns off while the 
projector is in use.
f
  Turn the <MAIN POWER> switch to <OFF>, and turn on the power again.
Blinking in red
(3 times)
Note
 
f
If the light source indicators <LIGHT1>/<LIGHT2> are still lit or blinking after taking the measures, set the  <MAIN POWER> switch to 
<OFF>, and ask your dealer for repairs.
 
f
The light source indicator corresponding to the light source being lit will light up in green if the projector is in projection mode and there is no 
indication of problem by lighting or blinking in red.
 
f
The function to detect the projector lens may or may not exist depending on the country or region where you purchased the product.
5. 1. 3. Temperature indicators
  • If a problem occurs inside the projector, the temperature indicator <TEMP> will inform you by lighting or blinking.
Indicator status
Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status
Warm-up status
Internal temperature is high 
(warning).
Internal temperature is high 
(standby status).
The cooling fan has 
stopped.
Cause
 
f
Did you turn on the power 
when the temperature 
was low (around 0 °C 
(32 °F))?
 
f
Is the air intake/exhaust port blocked?
 
f
Is the room temperature high?
Solution
 
f
Wait at least five minutes 
in the current status.
 
f
Use the projector 
in an appropriate 
operating environment 
temperature
*1
.
 
f
Remove any objects that are blocking the air intake/
exhaust port.
 
f
Use the projector in an appropriate operating 
environment temperature
*1
.
 
f
Do not use the projector at an altitude of 4 200 m 
(13 780') or higher above sea level.
 
f
Turn the <MAIN POWER> 
switch to <OFF>, 
and do repairs.
*1  For details of operating environment temperature of the projector, refer to “Operating environment temperature”.
Note
 
f
If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
INF-26
SECTION 1 SERVICE INFORMATION
< RZ970/RW930/RX110 >
5. 2. Shutdown system
•   This projector provides the shutdown function to set into the standby mode immediately for product safety when the projector    
has the fan operation error or lightning error. 
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
Not lighting or flashing
Power circuit (P-P.C.Board)
Fuse (F9001) : Rated 12A
Blown out of fuse
(with another reason)
Power circuit (P-P.C.Board)
Thermistor (CF9001, CF9002) : 115
±5℃
Air intake port blocked
Power circuit failure
STANDBY/ON blinks
3 times in red
F90/F91/F92 FPGA config error or communication 
error
Failure on signal processing part
F90:No response
F91:FPGA1 config error
F92:FPGA2 config error
Main firmware boot error
Main microprocessor rewrite error
A98
Formatter status error
DG-P.C.Board failure, 
Connector contact failure
FH0/FH1
FH2/FH3
Phosphor wheel rotation speed
 a
 Under 100Hz/8sec
 
*  FH1/FH3:Detected by FPGA
       (FH0/FH2:Detected by FM)
Connector contact failure
Phosphor wheel or drive circuit failure
CW-P.C.Board failure 
FH0/FH1:PW1
FH2/FH3:PW2
F85/F86
Color wheel rotation speed
 a
 Under 100Hz/8sec
 
*  F86:Detected by FPGA
       (F85:Detected by FM)
Connector contact failure
Color wheel or drive circuit failure
CW-P.C.Board failure 
STANDBY/ON lights
in red
TEMP lights
H11
Intake air temperature sensor
     a Lower than -20ºC
Intake air temperature sensor connector 
contact failure or disconnect
H12
Optical module temperature sensor
     a Lower than -20ºC
DMD temperature sensor error
(FM-P.C.Bosrd)
H13
Exhaust air temperature sensor
     a Lower than -20ºC
Exhaust air temperature sensor connector 
contact failure or disconnect
H14/H15
LD1 temperature sensor (H14)
LD2 temperature sensor (H15)
     a Lower than -20ºC
LD1/LD2 temperature sensor connector
contact failure or disconnect
TEMP blinks 3 times 
(In Warning: TEMP lights)
FE1 - FE9
FF0 - FF1
Each fan sense signal
     a  Fan rotation is lower than 70% of 
target for more than 5 seconds
Connector disconnection
Fan control circuit failure
Fan rotation error, end of life
If one of the fans stops, 
the projector reduces the 
LD output power.
If more than two fans have 
an error, the projector shut 
down.
FJ0 (PUMP1)
FJ1 (PUMP2)
Each pump sense signal
     a  Fan rotation is lower than 70% of 
target for more than 5 seconds
Connector disconnection
Pump control circuit failure
Pump rotation error, end of life
INF-27
SECTION 1 SERVICE INFORMATION
< RZ970/RW930/RX110 >
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
TEMP blinks 2 times 
(In Warning: TEMP lights)
U21
(U11)
Intake air temperature sensor
     a More than 48ºC *1
Abnormal intake air temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 46ºC)
"TEMPERATURE 
WARNING"
U22
(U12)
Optical module temperature sensor
     a More than 75ºC *1
Abnormal DMD temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 73ºC)
"TEMPERATURE 
WARNING"
U23
(U13)
Exhaust module temperature sensor
     a More than 65ºC *1
Abnormal exhaust air temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 63ºC)
"TEMPERATURE 
WARNING"
U24
(U14)
Optical module temperature sensor
     a  Lower than 8 ºC for more than 5 
min, after power on.
Operating environment temperature is 
too low.
U25/U26
(U16/U18)
LD1 temperature sensor (U25)
LD2 temperature sensor (U26)
     a More than 80ºC *1
Abnormal LD units temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 78ºC) 
"TEMPERATURE 
WARNING"
LIGHT blinks 3 times
FL1 (LD1)
FL2 (LD2)
LD driver microprocessor status
     a  Status is other than during normal 
operation
       *  If all of the LD units has become 
unlit, shut down
LD unit deterioration
Lighting failure of the LD units
LD driver circuit is abnormal
LIGHT blinks 2 times
FA8 (LD1)
FC8 (LD2)
LD driver microprocessor status
     a LD unit open fault
      *  If all of the LD units has become 
unlit, shut down
When "ERROR OSD" is 
set to ON
"LD*  ERROR"
 
 
 
 
*1 :   The threshold values are just reference temperature at operation mode (Normal), floor installed and less
                                                    than 1400m altitude. They are depending on the operating mode and installed condition.
 [Note]
 • 
[SELF TEST] can be checked in the [PROJECTOR SETUP] menu → [STATUS] → [SELF TEST].
 
  Can not checked if projector shutdown.
INF-28
SECTION 1 SERVICE INFORMATION
< RZ970/RW930/RX110 >
Serial terminal connection example
LAN terminal connection example
Serial terminal connection
D-sub 9pin (male/female RS-232C straight)
LAN terminal connection
LAN cable. (When connecting directly, use a cross cable)
Serial terminal connection
LAN terminal connection
Projector
SERIAL IN
Communication cable (straight)
Computer
D-Sub 9P
(male)
LAN cable (straight)
LAN cable (straight)
Hub
Projector
LAN
Computer
5. 3. System log data acquisition method
* The log data acquisition via LAN terminal or serial terminal.
5. 3. 1. Equipment to be used
  1. Computer : Use it for the log data acquisition.
  2. Communication cable :
  
  3. Service Firmware : [DataLogBackup.exe] Download from the projector service Web (PASS).
5. 3. 2. Connection preparations
  1. Check the settings of the projector.
 
    1) The [INPUT SELECT] of sub menu [RS-232C] must be set according to the connection method.
    2) The [EMULATE] of sub menu [RS-232C], please set to [DEFAULT]. (in service mode)
    3) Check the RS-232C settings (ID, Baudrate and Parity) and take a note.
 
 
    1) The [DIGITAL LINK MODE] of sub menu [NETWORK], is select to [AUTO] or [ETHERNET].
    2) Check the network IP address of the projector and take a note.
    3) Set the IP address of computer to approximate value of projector IP address.
   
    [Note]
    •  If you have changed the each menu settings, please return settings of the original (customers) after work.
  2. Connect the projector and the PC by using a communication cable.
5. 3. 3. Acquisition of log data
  1. Switch the projector to "Normal-Standby" mode (Power indicator is lighting in red).
  2. Activate a [DataLogBackup.exe] service firmware.
Page of 125
Display