SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
Bit
Self-test indication
Details
Probable cause
Related P.C.Board
40
00000100 00000000
Unused
-
41
00000200 00000000
Unused
-
42
00000400 00000000
FE1/(F50) Intake fan 3 error /(Warning)
DG、RT
43
00000800 00000000
FE2/(F51) Phosphor wheel 1 fan error /(Warning)
DG、RB
44
00001000 00000000
FE3/(F52) Phosphor wheel 2 fan error /(Warning)
DG、RT
45
00002000 00000000
FE4/(F53) Power intake fan error /(Warning)
DG,R
46
00004000 00000000
FE5/(F54) Drive fan error /(Warning)
DG
47
00008000 00000000
FE6/(F55) Power exhaust fan error /(Warning)
DG
48
00010000 00000000
FE7/(F56) DMD fan error /(Warning)
DG
49
00020000 00000000
FE8/(F57) Exhaust fan 1 error /(Warning)
DG,BR
50
00040000 00000000
FE9/(F58) Exhaust fan 2 error /(Warning)
DG
51
00080000 00000000
FF0/(F59) Intake fan 2 error /(Warning)
DG,RM
52
00100000 00000000
FF1/(F70) Intake fan 1 error /(Warning)
DG,RM
53
00200000 00000000
Unused
-
54
00400000 00000000
Unused
-
55
00800000 00000000
Unused
-
56
01000000 00000000
Unused
-
57
02000000 00000000
Unused
-
58
04000000 00000000
Unused
-
59
08000000 00000000
Unused
-
60
10000000 00000000
Unused
-
61
20000000 00000000
FJ0/(F00)
Liquid cooling pump1 error /(warning)
DG、BR
62
40000000 00000000
FJ1/(F01)
Liquid cooling pump2 error /(warning)
DG、BR
63
80000000 00000000
Unused
-
64
00000000 00000001
Unused
-
65
00000000 00000002
Unused
-
66
00000000 00000004
Unused
-
67
00000000 00000008
Unused
-
68
00000000 00000010
U25
LD1 temperature error
D,DR
69
00000000 00000020
U26
LD2 temperature error
A,DG,RT
70
00000000 00000040
Unused
-
71
00000000 00000080
Unused
-
72
00000000 00000100
H14
LD1 temperature sensor not present
LD1 temperature sensor has breaking
of wire, or connector (DR6) is
disconnected
DR
73
00000000 00000200
H15
LD2 temperature sensor not present
LD2 temperature sensor has breaking
of wire, or connector (RT12/RT1) is
disconnected
A,DG,RT
74
00000000 00000400
Unused
-
75
00000000 00000800
Unused
-
76
00000000 00001000
U16
LD1 temperature warning
D,DR
77
00000000 00002000
U17
LD2 temperature warning
A,DG,RT
78
00000000 00004000
Unused
-
79
00000000 00008000
Unused
-
80
00000000 00010000
F91
FPGA1 configuration error
A
81
00000000 00020000
F92
FPGA2 configuration error
A,DG
82
00000000 00040000
F90
FPGA configuration error
A,DG
83
00000000 00080000
Unused
-
84
00000000 00100000
Unused
-
LOWE
R
Fan or fan drive circuit is failure
Fan replacement time.
Pump or pump drive circuit is failure
Liquid cooling unit replacement time
U
PPER
Environment temperature is too high
Radiator clogging
Liquid cooling unit is failure
High altitude mode is mis select
Environment temperature is too high
Radiator clogging
Liquid cooling unit is failure
High altitude mode is mis select
Signal processing circuit failure
Error code (hex)
INF - 28
SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
Bit
Self-test indication
Details
Probable cause
Related P.C.Board
85
00000000 00200000
Unused
-
86
00000000 00400000
F96
Lens mounter error
Stepping motor failure
[LENS CALIBRATION] is not
correctly
RM, DG
87
00000000 00800000
F61
LD driver 1 communication error
Communication error with the LD1
driver
D, DG
88
00000000 01000000
F62
LD driver 2 communication error
Communication error with the LD2
driver
D, DG
89
00000000 02000000
FA8
LD1 Open failure (unrecoverable)
LD1 lighting failure
DR
90
00000000 04000000
FC8
LD2 Open failure (unrecoverable)
LD2 lighting failure
DR
91
00000000 08000000
Unused
-
92
00000000 10000000
FL1
Unexpected LD1 OFF
LD1 lighting failure
D,DG
93
00000000 20000000
FL2
Unexpected LD2 OFF
LD2 lighting failure
D,DG
94
00000000 40000000
Unused
-
95
00000000 80000000
Unused
-
96
00000001 00000000
F65
LD sub microprocessor error
DR circuit failure
DR
97
00000002 00000000
Unused
-
98
00000004 00000000
A08
Sub microprocessor communication
error (R8)
Communication error with the sub
microprocessor
A,DG
99
00000008 00000000
A41
IIC communication error1 (RTC)
A,DG,RM
100
00000010 00000000
A42
IIC communication error2 (EEPROM)
A
101
00000020 00000000
Unused
-
102
00000040 00000000
Unused
-
103
00000080 00000000
Unused
-
104
00000100 00000000
Unused
-
105
00000200 00000000
A47
IIC communication error7 (EDID DIGITAL) 
A
106
00000400 00000000
A48
IIC communication error8 (EDID ANALOG) 
A
107
00000800 00000000
A49
IIC communication error9 (ADC1) 
A
108
00001000 00000000
A50
IIC communication error10 (ADC2) 
A
109
00002000 00000000
A51
IIC communication error11
(ACCELERATION SENSOR)
A
110
00004000 00000000
Unused
-
111
00008000 00000000
A53
IIC communication error13 (HD BaseT)
Signal processing circuit failure
A
112
00010000 00000000
A54
IIC communication error14 (ATM SENSOR)
RM circuit failure
A,DG,RM
113
00020000 00000000
Unused
-
114
00040000 00000000
Unused
-
115
00080000 00000000
Unused
-
116
00100000 00000000
F85
CW(Trimming wheel) error (FM)
FM、DG、RT
117
00200000 00000000
F86
CW(Trimming wheel) error (FPGA)
DG
118
00400000 00000000
Unused
-
119
00800000 00000000
A94
FPGA1 communication error
A
120
01000000 00000000
A95
FPGA2 communication error
A、DG
121
02000000 00000000
Unused
-
122
04000000 00000000
Unused
-
123
08000000 00000000
A98
FM status error
FM circuit or DR circuit failure
DG、FM
124
10000000 00000000
F97
GEOMERTY communication error
GEOMETORY IC failure
DG
125
20000000 00000000
Unused
-
126
40000000 00000000
Unused
-
127
80000000 00000000
Unused
-
Error code (hex)
U
PPER
Signal processing circuit failure
Signal processing circuit failure
CW Abnormal operation
Signal processing circuit failure
INF - 29
SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
  6. 3. Troubleshooting
* The letters in the left of inspection items indicate the P.C. Boards related to their respective descriptions.
When checking and replacing the print circuit board, take care in static electricity, use an antistatic wrist strap
 or wear the anti-static electricity gloves.
DG
P
DG
A
* The AC voltage reduction or instantaneous power cut, makes the Light source turned off. Confirm the situation of power supply.
D
 Check and replace the A-P.C.Board
 ■ Light source does not turn ON. (Light1 and Light2 indicator blink 3 times)
 Confirm the connection of each connector
    P4~D1,DG9/DG19~D4, D2~DR1/DR2, DR3/DR4~LD
 Connect the cables properly
 After power turned on, trimming wheel and a phosphor
 wheel are rotating ? (Rotational noise check)
 Check the trimming wheel and a phosphor wheel,
 and connection
 ■ Power does not turn ON. (ON/STANDBY indicator does not light in red.)
 Confirm the connection of each connector
    AC inlet~P2, P6~DG1, DG6~R1
 Connect the cables properly
 Check the voltage of DG1 connector 1 pin is 3.3V
 Replace the P-P.C.Board
 Check and replace the DG-P.C.Board
 ■ Power does not turn ON. (ON/STANDBY indicator blink 3 times)
 Confirm the connection of each connector.
     P5~DG12, P6~A1/DG1, A2~DG2
 Confirm the connection of each connector
A
 Check the voltage of A1 connector
    1 pin : 3.3V,  3 pin : 5V
P
 Replace the P-P.C.Board
D
 LD driver input voltage check
    Lighting mode (power LED is green) :
    B1 connector 1pin DC380V, 4pin DC18V
P
 Replace the P-P.C.Board.
 Replace each D-P.C.Board.
[Note]
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
NG
OK
NG
OK
INF - 30
SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
D
A
 Confirm the connection of each connector
    P4~D1, DG9/DG19~D4, D2~DR1/DR2,
    DR3/DR4~LD
 Connect the cables properly
 Confirm the connection of each connector
    D2~DR1/DR2, DR3/DR4~LD
 Connect the cables properly
 Replace the LD unit of corresponding failure
 ■ No image appears (picture is abnormal)
 Is a menu screen displayed ?
 No image during DVI-D input
 Follow the section "●DVI-D input check"
 Confirm the connection of each connector
 Connect the cables properly
 Check the input image other than solid black image
 No image during VIDEO input
 Follow the section "●VIDEO input check"
 No image during Y/C input
 Replace each D-P.C.Board.
 ■ Light source does not turn ON. (Indicator blink 2 times of either Light1 or Light2)
 ■ Light source does not turn ON. (Indicator blink 3 times of either Light1 or Light2)
 Follow the section "●Y/C input check"
 No image during HDMI input
 Follow the section "●HDMI input check"
 No image during DIGITAL LINK input
 Follow the section "●DIGITAL LINK input check"
 Test pattern be displayed ?
 Check the IC3058 and peripheral circuit
 No image during RGB1 input
 Follow the section "●RGB1 input check"
 No image during RGB2 input
 Follow the section "●RGB2 input check"
 No image during SDI input (RZ670 only)
 Follow the section "●SDI input check" (RZ670 only)
 The check of LD unit failure with a [self check] or [status] screen.
OK
NG
NG
OK
NG
OK
NG
OK
NG
NG
NG
NG
NG
NG
NG
NG
OK
NG
OK