Panasonic PT-RZ120 (serv.man2) Service Manual ▷ View online
8
PREFACE
< RZ120 >
*4 When the lens ET-DLE055 is used, the maximum size is 5.08 m (200"). When the lens ET-DLE035 is used, the maximum size is 2.54 m (100") to
8.89 m (350").
*5 Average value. Weight varies for each product.
*6 When using the projector at an altitude lower than 2 700 m (8 858') above sea level, and the operating environment temperature becomes 30 °C
(86 °F) or higher, the light output may be reduced to protect the projector. When using the projector at an altitude between 2 700 m (8 858') and
4 200 m (13 780'), and the operating environment temperature becomes 25 °C (77 °F) or higher, the light output may be reduced to protect the
projector.
<RGB 1 IN> terminal
1 set (BNC x 5 (RGB/YP
B
P
R
/YC
B
C
R
x 1))
RGB signal
0.7 V [p-p] 75 Ω (SYNC ON GREEN: 1.0 V [p-p] 75 Ω)
SYNC/HD
SYNC/HD
TTL high impedance, automatic positive/negative
polarity compatible
VD
TTL high impedance, automatic positive/negative
polarity compatible
YP
B
P
R
signal
Y: 1.0 V [p-p] including synchronization signal, P
B
P
R
: 0.7 V [p-p] 75 Ω
<RGB 2 IN> terminal
1 set, high-density D-Sub 15 p (female)
RGB signal
RGB signal
0.7 V [p-p] 75 Ω (SYNC ON GREEN: 1.0 V [p-p] 75 Ω)
SYNC/HD
SYNC/HD
TTL high impedance, automatic positive/negative
polarity compatible
VD
TTL high impedance, automatic positive/negative
polarity compatible
YP
B
P
R
signal
Y: 1.0 V [p-p] including synchronization signal, P
B
P
R
: 0.7 V [p-p] 75 Ω
<DVI-D IN> terminal
1 set, DVI-D 24 p, single link, DVI 1.0 compliant, HDCP compatible
<HDMI IN> terminal
1 set, HDMI 19 p, HDCP 2.2 compatible, Deep Color compatible
<SDI IN> terminal
1 set (BNC)
SD-SDI signal
SD-SDI signal
SMPTE ST 259 compliant
HD-SDI signal
SMPTE ST 292 compliant
3G-SDI signal
SMPTE ST 424, 425-2 compliant
<SERIAL/MULTI PROJECTOR
SYNC IN>/ <SERIAL/MULTI
PROJECTOR SYNC OUT>
terminal
D-Sub 9 p, 1 set each, RS-232C compliant, for computer control
<REMOTE 1 IN>/ <REMOTE 1
OUT> terminal
M3 stereo mini jack, 1 set each, for remote control (wired)/for projector connection control
<REMOTE 2 IN> terminal
1 set, D-Sub 9 p, for contact control
<DIGITAL LINK/LAN> terminal 1 set, RJ-45, for network and DIGITAL LINK connections (HDBaseT
TM
compliant), PJLink (class 2)
compatible, 100Base-TX, Art-Net compatible, HDCP 2.2 compatible, Deep Color compatible
<LAN> terminal
1 set, RJ-45, for network connection, PJLink (class 2) compatible, 10Base-T/100Base-TX, Art-Net
compatible
Note
f
The model numbers of accessories and optional accessories are subject to change without prior notice.
*1 The lens for PT-RZ120L series is sold separately.
*2 Value is for the supplied standard zoom lens. The value varies depending on the lens.
*3 Measurement, measuring conditions, and method of notation all comply with ISO/IEC 21118:2012 international standards.
2. 2 Connecting terminal
9
PREFACE
< RZ120 >
RGB input
f
Resolution: 640 x 400 to 1 920 x 1 200
f
Dot clock frequency: 162 MHz or less
f
PIAS (Panasonic Intelligent Auto Scanning) system
YC
B
C
R
/YP
B
P
R
input
f
Resolution: 480i/576i to 1 920 x 1 080
f
Dot clock frequency: 148.5 MHz or less
f
The HD/SYNC and VD terminals do not support 3 value SYNC.
DVI-D input
f
Moving image signal resolution: 480i
*1
/576i
*1
to 1 920 x 1 080
Still image signal resolution: 640 x 400 to 1 920 x 1 200 (non-interlace)
f
Dot clock frequency: 25 MHz to 162 MHz
HDMI input
f
Moving image signal resolution: 480i
*1
/576i
*1
to 4 096 x 2 160
Still image signal resolution: 640 x 400 to 1 920 x 1 200 (non-interlace)
f
Dot clock frequency: 25 MHz to 594 MHz
DIGITAL LINK input
f
Moving image signal resolution: 480i
*1
/576i
*1
to 4 096 x 2 160
Still image signal resolution: 640 x 400 to 1 920 x 1 200 (non-interlace)
f
Dot clock frequency: 25 MHz to 297 MHz
SDI input
SD-SDI signal
HD-SDI signal
3G-SDI signal
SD-SDI signal
HD-SDI signal
3G-SDI signal
*1 Pixel-Repetition signal (dot clock frequency 27.0 MHz) only
2. 3 Compatible signal
• For details of the types of video signals that can be used with the projector, refer to operating Instructions “List of compatible signals”
10
PREFACE
< RZ120 >
2. 4. Dimensions
Unit: mm
221 (8-11/16")
249 (9-13/16")
498 (19-19/32")
457 (18")
442 (17-13/32")
20.5 (13/16")
115.5 (4-9/16")
200 (7-7/8")
43 (1-11/16")
538 (21-3/16")
* The above dimensions are obtained when the standard zoom lens is attached.
* Actual dimensions may differ depending on the product.
SECTION
1
INF-1
CONTENTS
1. The name of each part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-2
1. 1. Remote controls
1. 2. Projector body
1. 3. Control panel
1. 4. Connecting terminals
1. 2. Projector body
1. 3. Control panel
1. 4. Connecting terminals
2. Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-6
3. Service Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-10
3. 1. Setting to Service Mode
3. 2. Resetting to User Mode
3. 3. Functions of Service Mode
3. 2. Resetting to User Mode
3. 3. Functions of Service Mode
4. Notes on service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-21
4. 1. Before service operation
4. 2. Service
4. 3. Security password
4. 2. Service
4. 3. Security password
5. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-24
5. 1. Power/Light source/Temperature indicators
5. 2. Shutdown system
5. 3. System log data acquisition method
5. 4. Troubleshooting
5. 2. Shutdown system
5. 3. System log data acquisition method
5. 4. Troubleshooting
SECTION 1 SERVICE INFORMATION
Click on the first or last page to see other PT-RZ120 (serv.man2) service manuals if exist.