DOWNLOAD Panasonic PT-RZ120 (serv.man2) Service Manual ↓ Size: 34.64 MB | Pages: 101 in PDF or view online for FREE

Model
PT-RZ120 (serv.man2)
Pages
101
Size
34.64 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / 1-CHIP DLP BASED PROJECTOR
File
pt-rz120-sm2.pdf
Date

Panasonic PT-RZ120 (serv.man2) Service Manual ▷ View online

5
PREFACE
< RZ120 >
CONTENTS
1. Safety Precautions
2. Specifications
SECTION 1 SERVICE INFORMATION
1. The name of each part
2. Menu Navigation
3. Service Mode
4. Notes on service
5. Troubleshooting
SECTION 2 DISASSEMBLY PROCEDURES
1. Parts Locations
2. Disassembly Instructions
SECTION 3 ADJUSTMENTS
1. Adjustment item and a procedure
2. Firmware update procedure
For the schematic diagram and parts list, refer to the separated booklet "Schematic diagram" and "Parts List" 
respectively.
6
PREFACE
< RZ120 >
1. Safety Precautions
1. 1. General Guidelines
- For continued safety, no modification of any circuit must be attempted.
- Unplug the power cord from the power outlet before disassembling this projector.
- Use correctly the supplied power cord and must ground it.
- It is advisable to use an isolation transformer in the AC power line before the service.
-  Be careful not to touch the rotation part (cooling fan, etc.) of this projector when you service with the upper case removed 
and the power supply turned ON.
-  Observe the original lead dress during the service. If a short circuit is found, replace all the parts overheated or damaged by 
the short circuit.
-  After the service, all the protective devices such as insulation barriers, insulation papers, shields, and isolation R-C combi-
nations must be properly installed.
- After the service, check the leakage current to prevent the customer from getting an electric shock.
1. 2. Leakage Current Check
1. Prepare the measuring circuit as shown in Fig.1.
    Be sure to use a voltmeter having the performance described in Table 1.
2. Assemble the circuit as shown in Fig. 2. Plug the power cord in a power outlet.
3. Connect M1 to T1 according to Fig. 2 and measure the voltage.
4. Change the connection of M1 from T1 to T2 and measure the voltage again.
5.  The voltmeter must read 0.375 V or lower in both of steps 3 and 4. This means that the current must be 0.75mA or  less.
6.  If the reading is out of the above standard, the projector must be repaired and rechecked before returning to the customer 
because of a possibility of an electric shock.
 
 
 
  
  
M1
M2
Rs
Cs
Rb
10KΩ ±0.1%
0.022µF
±1.0%
Vb
(V) V
Rs: 1500 Ω±0.1%
Cs: 0.22 µF±1.0%
Rb: 500 Ω±0.1%
to T1
or T2
in FIg.2
Weighted leakage current=Vb / 500 (A)
Fig. 1
Isolation transformer
T1
T2
connection
to power outlet
M1
M2
Fig.2
Projector
Measuring
Circuit (Fig.1)
Performance
Voltmeter
(rms reading)
Accurancy: 
≤ 2%
Input resistance: 
≥ 1 MΩ
Input capacitance:  ≤ 200 pF
Frequency range:  15 Hz to 1 MHz
Table. 1
7
PREFACE
< RZ120 >
2. Specifications
2. 1 Specifications
• 
The specifications of the projector are as follows.
Power supply
100 V - 240 V ~ (100 V - 240 V alternating current), 50 Hz/60 Hz
Power consumption
1 100 W (11 A - 4.5 A)
Power consumption (during 
standby)
When [STANDBY MODE] is set to [ECO]: Approx. 0.5 W
When [STANDBY MODE] is set to [NORMAL]: Approx. 7 W
When the [QUICK STARTUP] function is enabled: Approx. 100 W
DLP chip
Size
17 mm (0.67") (aspect ratio 16:10)
Display system
DLP chip x 1, DLP projection system
Number of pixels 2 304 000 pixels (1 920 x 1 200 dots)
Lens
*1
Electric zoom
1.7 to 2.4:1
Electric focus
F = 1.7 to 1.9
f = 25.6 mm to 35.7 mm
Light source
Laser light source, 2 sets
Light output
*2
12 000 lm
*3
(When [OPERATING MODE] in [OPERATION SETTING] is set to [NORMAL])
Center to corner zone ratio
*3
90 %
Contrast ratio
*3
10 000:1 (when [DYNAMIC CONTRAST] is set to [3])
Projected image size
*4
1.27 m (50") to 15.24 m (600")
Image aspect ratio
16:10
Projection method
[FRONT]/[FLOOR], [FRONT]/[CEILING], [REAR]/[FLOOR], [REAR]/[CEILING]
Power cord length
3.0 m (118-1/8")
Outer case
Molded plastic
Outer color
Black model
Black
White model
White
Dimensions
Width
498 mm (19-19/32")
Height
200 mm (7-7/8") (with legs at shortest position)
Depth
PT-RZ120
581 mm (22-7/8") (including standard zoom lens)
PT-RZ120L
538 mm (21-3/16") (excluding the Lens Mount Cover 
and optional lens)
Weight
PT-RZ120
Approx. 23.6 k] (51.9 lbs.)
*5
 (including standard zoom 
lens)
PT-RZ120L
Approx. 22.8 k] (50.2 lbs.)
*5
 (excluding the Lens Mount 
Cover and optional lens)
Noise level
*3
44 dB
When [OPERATING MODE] in [OPERATION 
SETTING] is set to [NORMAL]
41 dB
When [OPERATING MODE] in [OPERATION 
SETTING] is set to [QUIET1]
38 dB
When [OPERATING MODE] in [OPERATION 
SETTING] is set to [QUIET2]
Laser 
Classification
Laser Class
USA and Canada: Class 3R (IEC 60825-1:2007)
Other countries or regions: Class 1 (IEC/EN 60825-1:2014)
Risk Group
ET-DLE035, ET-DLE055, ET-DLE060, 
ET-DLE085, ET-DLE105, ET-DLE150, 
ET-DLE170
Risk Group 2 (IEC 62471-5:2015)
ET-DLE250, ET-DLE350, ET-DLE450
Risk Group 3 (IEC 62471-5:2015)
Operating 
environment
Operating 
environment 
temperature
*6
0 °C (32 °F) to 45 °C (113 °F)
Operating 
environment 
humidity
10 % to 80 % (no condensation)
Remote 
control
Power supply
DC 3 V (AAA/R03/LR03 battery x 2)
Operating range Within approx. 30 m (98'5") (when operated directly in front of signal receiver)
Weight
102 ] (3.6 ozs.) (including batteries)
Dimensions
Width: 48 mm (1-7/8"), Height: 145 mm (5-23/32"), Depth: 27 mm (1-1/16")
8
PREFACE
< RZ120 >
*4  When the lens ET-DLE055 is used, the maximum size is 5.08 m (200"). When the lens ET-DLE035 is used, the maximum size is 2.54 m (100") to
8.89 m (350").
*5  Average value. Weight varies for each product.
*6  When using the projector at an altitude lower than 2 700 m (8 858') above sea level, and the operating environment temperature becomes 30 °C
(86 °F) or higher, the light output may be reduced to protect the projector. When using the projector at an altitude between 2 700 m (8 858') and 
4 200 m (13 780'), and the operating environment temperature becomes 25 °C (77 °F) or higher, the light output may be reduced to protect the 
projector.
<RGB 1 IN> terminal
1 set (BNC x 5 (RGB/YP
B
P
R
/YC
B
C
R
 x 1))
RGB signal
0.7 V [p-p] 75 Ω (SYNC ON GREEN: 1.0 V [p-p] 75 Ω)
SYNC/HD
TTL high impedance, automatic positive/negative 
polarity compatible
VD
TTL high impedance, automatic positive/negative 
polarity compatible
YP
B
P
R
 signal
Y: 1.0 V [p-p] including synchronization signal, P
B
P
R
: 0.7 V [p-p] 75 Ω
<RGB 2 IN> terminal
1 set, high-density D-Sub 15 p (female)
RGB signal
0.7 V [p-p] 75 Ω (SYNC ON GREEN: 1.0 V [p-p] 75 Ω)
SYNC/HD
TTL high impedance, automatic positive/negative 
polarity compatible
VD
TTL high impedance, automatic positive/negative 
polarity compatible
YP
B
P
R
 signal
Y: 1.0 V [p-p] including synchronization signal, P
B
P
R
: 0.7 V [p-p] 75 Ω
<DVI-D IN> terminal
1 set, DVI-D 24 p, single link, DVI 1.0 compliant, HDCP compatible
<HDMI IN> terminal
1 set, HDMI 19 p, HDCP 2.2 compatible, Deep Color compatible
<SDI IN> terminal
1 set (BNC)
SD-SDI signal
SMPTE ST 259 compliant
HD-SDI signal
SMPTE ST 292 compliant
3G-SDI signal
SMPTE ST 424, 425-2 compliant
<SERIAL/MULTI PROJECTOR 
SYNC IN>/ <SERIAL/MULTI 
PROJECTOR SYNC OUT> 
terminal
D-Sub 9 p, 1 set each, RS-232C compliant, for computer control
<REMOTE 1 IN>/ <REMOTE 1 
OUT> terminal
M3 stereo mini jack, 1 set each, for remote control (wired)/for projector connection control
<REMOTE 2 IN> terminal
1 set, D-Sub 9 p, for contact control
<DIGITAL LINK/LAN> terminal 1 set, RJ-45, for network and DIGITAL LINK connections (HDBaseT
TM
 compliant), PJLink (class 2) 
compatible, 100Base-TX, Art-Net compatible, HDCP 2.2 compatible, Deep Color compatible
<LAN> terminal
1 set, RJ-45, for network connection, PJLink (class 2) compatible, 10Base-T/100Base-TX, Art-Net 
compatible
Note
 
f
The model numbers of accessories and optional accessories are subject to change without prior notice.
*1  The lens for PT-RZ120L series is sold separately.
*2  Value is for the supplied standard zoom lens. The value varies depending on the lens.
*3  Measurement, measuring conditions, and method of notation all comply with ISO/IEC 21118:2012 international standards.
2. 2 Connecting terminal
Page of 101
Display