Panasonic PT-MZ16K / PT-MZ13K / PT-MZ10K (serv.man2) Service Manual ▷ View online
8
PREFACE
<MZ16K/MZ13K/MZ10K>
Chapter 7 Appendix — Specifications
ENGLISH - 235
Operating
environment
Operating
environment
temperature
0 °C (32 °F) to 45 °C (113 °F)
*6
Operating
environment
humidity
10 % to 80 % (no condensation)
Remote
control
Power supply
DC 3 V (AAA/R03/LR03 battery x 2)
Operating range Within approx. 30 m (98'5") (when operated directly in front of signal receiver)
Weight
Weight
102 ] (3.6 ozs.) (including batteries)
Dimensions
Width: 48 mm (1-7/8"), Height: 145 mm (5-23/32"), Depth: 27 mm (1-1/16")
*1 Measurement, measuring conditions, and method of notation all comply with ISO/IEC 21118:2012 international standards.
*2 Average value. Weight varies for each product.
*3 When the throw ratio is 2.9:1 or less: Risk group 2
When the throw ratio exceeds 2.9:1: Risk group 3
*4 When the throw ratio is 3.4:1 or less: Risk group 2
When the throw ratio exceeds 3.4:1: Risk group 3
*5 When the throw ratio is 4.6:1 or less: Risk group 2
When the throw ratio exceeds 4.6:1: Risk group 3
*6 When using the projector at an altitude lower than 2 700 m (8 858') above sea level, and the operating environment temperature becomes 35 °C
(95 °F) or higher, the light output may be reduced to protect the projector.
Note
f
The model numbers of accessories and optional accessories are subject to change without prior notice.
r
Connecting terminal
<RGB IN> terminal
1 set, high-density D-Sub 15 p (female)
RGB signal
RGB signal
0.7 V [p-p] 75 Ω (SYNC ON GREEN: 1.0 V [p-p] 75 Ω)
SYNC/HD
SYNC/HD
TTL high impedance, automatic positive/negative
polarity compatible
VD
TTL high impedance, automatic positive/negative
polarity compatible
YP
B
P
R
signal
Y: 1.0 V [p-p] including synchronization signal, P
B
P
R
: 0.7 V [p-p] 75 Ω
<DVI-D IN> terminal
1 set, DVI-D 24 p, single link, DVI 1.0 compliant, HDCP compatible
<HDMI IN> terminal
1 set, HDMI 19 p, HDCP 2.2 compatible, Deep Color compatible
<SDI IN> terminal
1 set (BNC)
HD-SDI signal
HD-SDI signal
SMPTE ST 292 compliant
3G-SDI signal
SMPTE ST 424, 425-2 compliant
<SERIAL/MULTI PROJECTOR
SYNC IN>/ <SERIAL/MULTI
PROJECTOR SYNC OUT>
terminal
D-Sub 9 p, 1 set each, RS-232C compliant, for computer control
<REMOTE 1 IN> terminal
1 set, D-Sub 9 p, for contact control
<REMOTE 2 IN>/ <REMOTE 2
OUT> terminal
M3 stereo mini jack, 1 set each, for remote control (wired)/for projector connection control
<DIGITAL LINK> terminal
1 set, RJ-45, for network and DIGITAL LINK connections (HDBaseT
TM
compliant), PJLink (class 2)
compatible, 100Base-TX, Art-Net compatible, HDCP 2.2 compatible, Deep Color compatible
<LAN> terminal
1 set, RJ-45, for network connection, PJLink (class 2) compatible, 10Base-T/100Base-TX, Art-Net
compatible
<DC OUT> terminal
USB connector (type A) x 1, for power supply (DC 5 V, maximum 2 A)
9
PREFACE
<MZ16K/MZ13K/MZ10K>
Chapter 7 Appendix — Specifications
236 - ENGLISH
r
Compatible signal
For details of the types of video signals that can be used with the projector, refer to “List of compatible
signals”.
RGB signal input
f
Resolution: 640 x 480 to 1 920 x 1 200
f
Dot clock frequency: 162 MHz or less
f
PIAS (Panasonic Intelligent Auto Scanning) system
YC
B
C
R
/YP
B
P
R
signal input
f
Resolution: 480p/576p to 1 920 x 1 080
f
Dot clock frequency: 148.5 MHz or less
f
The HD/SYNC and VD terminals do not support 3 value SYNC.
DVI-D signal input
f
Moving image signal resolution: 480p/576p to 1 920 x 1 080
Still image signal resolution: 640 x 480 to 1 920 x 1 200 (non-interlace)
Still image signal resolution: 640 x 480 to 1 920 x 1 200 (non-interlace)
f
Dot clock frequency: 25 MHz to 162 MHz
HDMI signal input
f
Moving image signal resolution: 480p/576p to 4 096 x 2 160
Still image signal resolution: 640 x 480 to 1 920 x 1 200 (non-interlace)
Still image signal resolution: 640 x 480 to 1 920 x 1 200 (non-interlace)
f
Dot clock frequency: 25 MHz to 594 MHz
DIGITAL LINK signal input
f
Moving image signal resolution: 480p/576p to 4 096 x 2 160
Still image signal resolution: 640 x 480 to 1 920 x 1 200 (non-interlace)
Still image signal resolution: 640 x 480 to 1 920 x 1 200 (non-interlace)
f
Dot clock frequency: 25 MHz to 297 MHz
SDI signal input
HD-SDI signal
3G-SDI signal
HD-SDI signal
3G-SDI signal
10
PREFACE
<MZ16K/MZ13K/MZ10K>
r
Dimensions
Chapter 7 Appendix — Dimensions
ENGLISH - 237
Dimensions
Unit: mm
294 (11-9/16")
325 (12-25/32")
650 (25-19/32")
316 (12-7/16")
588 (23-5/32")
26 (1-1/32")
113 (4-7/16")
211 (8-5/16")
3 (1/8")
440 (17-5/16")
* Actual dimensions may differ depending on the product.
SECTION
1
INF-1
(2019-11)
CONTENTS
1. The name of each part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-2
1.1. Remote controls
1.2. Projector body
1.3. Control panel
1.4. Connecting terminals
1.2. Projector body
1.3. Control panel
1.4. Connecting terminals
2. Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-7
2.1. On-screen
3. Service Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-12
3.1. Setting to Service Mode
3.2. Resetting to User Mode
3.3. Functions of Service Mode
3.2. Resetting to User Mode
3.3. Functions of Service Mode
4. Notes on service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-24
4.1. Before service operation
4.2. Service
4.3. Note on the parts replacement work
4.4. Replacement of consumable parts
4.5. Security password
4.2. Service
4.3. Note on the parts replacement work
4.4. Replacement of consumable parts
4.5. Security password
5. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INF-31
5.1. LIGHT/TEMP/FILTER indicators
5.2. Information monitor
5.3. Shutdown system
5.4. System log data acquisition method
5.5. Self-diagnosis & error code table
5.6. Self-diagnosis information acquisition by control commands
5.7. Troubleshooting
5.2. Information monitor
5.3. Shutdown system
5.4. System log data acquisition method
5.5. Self-diagnosis & error code table
5.6. Self-diagnosis information acquisition by control commands
5.7. Troubleshooting
SECTION 1 SERVICE INFORMATION
Click on the first or last page to see other PT-MZ16K / PT-MZ13K / PT-MZ10K (serv.man2) service manuals if exist.