DOWNLOAD Panasonic PT-LW330 / PT-LW280 / PT-LB360 / PT-LB330 / PT-LB300 / PT-LB280 (serv.man5) Service Manual ↓ Size: 35.19 MB | Pages: 88 in PDF or view online for FREE

Model
PT-LW330 PT-LW280 PT-LB360 PT-LB330 PT-LB300 PT-LB280 (serv.man5)
Pages
88
Size
35.19 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / LCD PROJECTOR
File
pt-lw330-pt-lw280-pt-lb360-pt-lb330-pt-lb300-pt-lb.pdf
Date

Panasonic PT-LW330 / PT-LW280 / PT-LB360 / PT-LB330 / PT-LB300 / PT-LB280 (serv.man5) Service Manual ▷ View online

-17-
Standby Mode Notice
Function
Eco
Normal
Serial command control 
*1
Network Function
--
Monitor Out
--
Audio Out
--
--
Auto Power On
This projector provides two types of standby mode, Eco standby and Normal standby. In the Eco and Normal mode, 
the following functions are restricted. To change the standby mode, use the projector's menu 
"Setting"
 Normal ............ Supply the power to the projector even after turning off the projector. 
 Eco ................. Select "Eco" when you do not use the projector via network. The projector's network function will 
stop when turning off the projector. 
When 
Eco is selected, several functions will be restricted. 
Restricted Function in the standby mode
 *1 Effective only power-on command.
-18-
Mechanical Disassembly
Caution
The parts and screws should be placed exactly the same 
position as the original otherwise it may cause loss of 
performance and product safety. 
6-1. Fuse disassembly
3-1. MAIN board disassembly
6. Filter board and power box disassembly
5. Duct disassembly
4.  Fan and optical parts disassembly
3. MAIN board unit disassembly
2. Top cover disassembly
 1. External air filter removal
7. Cable reforming
Mechanical disassembly should be made following procedures 
in numerical order.
Following steps show the basic procedures, therefore 
unnecessary step may be ignored. 
 Screw specifications
(Type Diameter x Length) mm
T type
M type
-19-
Mechanical Disassembly
1. Filter unit disassembly
Fig. 1
1.  Remove the 
 air filter cover and air filter
.
Air filter cover
Air filter
-20-
Mechanical Disassembly
2. Top cover disassembly
Fig. 2
Cabinet top
Lamp cover
1. Loosen 1 screw A (M3X9) and remove the lamp cover.
2. Remove 6 screws B (T3x8) and 4 screws C (M3x8) to remove the cabinet top.
A
C
B
B
C
C
C
Front receiving 
window for 
remote control
Lens decoration 
ring
Page of 88