Panasonic PT-FZ570 / PT-FW530 / PT-FX500 / PT-EZ590 / PT-EW650 / PT-EW550 / PT-EX620 / PT-EX520 / PT-FZ570C / PT-FW530C / PT-FX500C / PT-SLZ71C / PT-SLW77C / PT-SLW67C / PT-SLX74C / PT-SLX64C Service Manual / Other ▷ View online
Order No. TSD1606I021
Details: ① There was a case that Configured Warning Temperature value of Intake temperature
in [Temperature Info] tab does not show correctly when Projector is monitored
by Early Warning Software (Ver. 2.4 or later) under the following conditions.
by Early Warning Software (Ver. 2.4 or later) under the following conditions.
(Conditions)
① Set [LAMP POWER] to 「NORMAL」 mode.
② Supply Input signal and display it.
② Supply Input signal and display it.
(This symptom does not occur if [LAMP POWER] is set to [ECO] mode or
no input signal condition.)
no input signal condition.)
Cause: ① There was a case that the transferred data from Projector to Early Warning Software
does not correct value if the Projector uses by above conditions.
The data transfer process has been changed.
The data transfer process has been changed.
Details: ② There was a case that 「Network Version」 of [Status] tab shows as "0.00" when Projector
is monitored by Early Warning Software (Ver. 2.4 or later).
(The correct display of version No. is "-.--".)
(The correct display of version No. is "-.--".)
Cause: ② There was a case that unnecessary version information sends to Early Warning Software.
Data transfer process of Version Information has been changed.
Details: ③ There was a case that System Log which has no actual data is stored when
Projector is monitored by Early Warning Software (Ver. 2.4 or later) or
Multi Projector Monitoring Control Software.
Multi Projector Monitoring Control Software.
(In case of Early Warning Software)
① Select to [Detailed/Overview] button, and Select to [History] tab.
② Error Log and System Log are stored into Error message file.
② Error Log and System Log are stored into Error message file.
(In case of Multi Projector Monitoring Control Software.)
① Select to [File] → [Saving Maintenance Log] button on [Device Monitoring] window.
② System Log is stored into Maintenance Log file.
② System Log is stored into Maintenance Log file.
Cause: ③ There was a case that System Log data is not transferred correctly to each application
software when System Log is stored.
Data transfer process of System Log data has been changed.
Data transfer process of System Log data has been changed.
EA2-06266
Subject : Configured Intake Warning Temperature of EWS Software
is not displayed correctly, etc.
is not displayed correctly, etc.
Please use this service information together with the Service Manual as follows :
Model No.
Order No.
Modification applied from
VED1604600CE
PT-FZ570, FW530, FX500
26, May. 2016
PT-SLZ71C, SLW77C, SLW67C, SLX74C, SLX64C
VED1604601CC
PT-EZ590, EW650, EW550, EX620, EX520
PT-FZ570C, FW530C, FX500C
PT-FZ570C, FW530C, FX500C
VED1604599CE
VED1604602CC
VED1604602CC
Details: ④ There was a case that after Projector's power is turned ON, Lamp is turned ON even if
Fan does not rotate.
(In this case, the Projector will be shut down after 30 seconds by fan error.)
(In this case, the Projector will be shut down after 30 seconds by fan error.)
Cause: ④ There was a case that Power ON control process does not operate correctly
when fan does not rotate.
Power ON control process has been changed.
Power ON control process has been changed.
Details: ⑤ There was a case that Input is not switched to 「NETWORK」 even if 「NETWORK」 input
is programmed by [SCHEDULE] function.
(This symptom does not occur other than 「NETWORK」 input.)
(This symptom does not occur other than 「NETWORK」 input.)
Cause: ⑤ There was a case that input switching process does not operate correctly
with 「NETWORK」 input.
Input switching process has been changed.
Input switching process has been changed.
Details: ⑥ There was a case that after Projector's power is turned ON, 「NTP SYNCHRONIZATION」
function does not complete the synchronization to network under the following conditions.
(Conditions)
① Set 「NTP SYNCRONIZATION」 of [DATE AND TIME ] menu to ON.
② Turn OFF the Projector's power, and then turn it to ON again.
② Turn OFF the Projector's power, and then turn it to ON again.
Cause: ⑥ By the timing of the communication process between Main microprocessor and
Network microcoprocessor at the time of Projector's power-up, there was a case that
「NTP SYNCRONIZATION」 function can not be executed.
「NTP SYNCRONIZATION」 process has been changed.
「NTP SYNCRONIZATION」 function can not be executed.
「NTP SYNCRONIZATION」 process has been changed.
Details: ⑦ There was a case that after Projector's power is turned ON, picture does not display
under the following conditions.
(Conditions)
① Select 「NETWORK」 input.
② Set [IN STANDBY MODE] of [AUDIO SETTING] menu to ON.
③ Turn OFF the Projector's power, and then turn it to ON again.
② Set [IN STANDBY MODE] of [AUDIO SETTING] menu to ON.
③ Turn OFF the Projector's power, and then turn it to ON again.
Cause: ⑦ There was a case that Audio signal detection does not operate correctly,
if [IN STANDBY MODE] is set to ON in [NETWORK] input mode.
Audio signal detection process has been changed.
Audio signal detection process has been changed.
Remedy:
Please download the following firmware from the PASS website, and update them.
Main firmware version : Version 1.08
FPGA firmware version : Version 1.01
Display