Panasonic PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE (serv.man11) Service Manual ▷ View online
ORDER NO. BSD1008A26CE
D10
3-chip DLP Based Projector
Model No.
PT-DZ8700U
PT-DS8500U
PT-DW8300U
PT-DZ110XE
PT-DS100XE
PT-DW90XE
PT-DW8300U
PT-DZ110XE
PT-DS100XE
PT-DW90XE
The projection lens is sold separately.
Rev.-1 (2017-06)
PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE
2
The service technician is required to read and follow the “Safety Precautions” and “Important Safety Notice” in this service manual.
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It dose not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the product or products dealt with in this service information by anyone else could result in serious injury or death.
WARNING : Use UV Radiation eye and skin protection during servicing.
CAUTION
Lithium Battery
Risk of explosion if battery is replaced by an incorrect type,
Risk of explosion if battery is replaced by an incorrect type,
Replace only with the same of equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
Precaution
If using of this projector at high altitudes (above 1,400m), set HIGHT ALTITUDE MODE to “ON”.
(Refer to “PROJECTOR SETUP menu” in Operating Instructions.)
Failure to observe this may cause malfunctions. Never use this projector at an altitude of 2,700m or higher.
Using this projector at high altitude, consult your dealer or Authorized Service Center about preparations.
(Refer to “PROJECTOR SETUP menu” in Operating Instructions.)
Failure to observe this may cause malfunctions. Never use this projector at an altitude of 2,700m or higher.
Using this projector at high altitude, consult your dealer or Authorized Service Center about preparations.
About lead free solder (PbF)
This projector is using the P.C.Board which applies lead free solder.
Use lead free solder in servicing from the standpoint of antipollution for the global environment.
Notes:
Use lead free solder in servicing from the standpoint of antipollution for the global environment.
Notes:
・Lead free solder: Sn-Ag-Cu (tin, silver and copper) has a higher melting point (approx. 217°C) than standard solder. Typically the melting point
・is 30~40 °C higher. When servicing, use a high temperature soldering iron with temperature limitation function and set it to 370 ± 10 °C.
・Be precautious about lead free solder. Sn-Ag-Cu (tin, silver and copper) will tend to splash when heated too high (approx. 600°C or higher).
・Use lead free solder for the P.C.Board (specified on it as “PbF”) which uses lead free solder. (When you unavoidably use lead solder, use lead
・solder after removing lead free solder. Or be sure to heat the lead free solder until it melts completely, before applying lead solder.)
・After soldering to double layered P.C.Boards, check the component side for excess solder which may flow onto the opposite side.
・is 30~40 °C higher. When servicing, use a high temperature soldering iron with temperature limitation function and set it to 370 ± 10 °C.
・Be precautious about lead free solder. Sn-Ag-Cu (tin, silver and copper) will tend to splash when heated too high (approx. 600°C or higher).
・Use lead free solder for the P.C.Board (specified on it as “PbF”) which uses lead free solder. (When you unavoidably use lead solder, use lead
・solder after removing lead free solder. Or be sure to heat the lead free solder until it melts completely, before applying lead solder.)
・After soldering to double layered P.C.Boards, check the component side for excess solder which may flow onto the opposite side.
About the identification of the lead free solder P.C.Board.
For the P.C.Board which applies lead free solder, the symbol as shown in the figure below is printed or stamped on the surface or the back of
P.C.Board.
For the P.C.Board which applies lead free solder, the symbol as shown in the figure below is printed or stamped on the surface or the back of
P.C.Board.
For US
There are special parts used in Panasonic LCD Projectors which are important for safety. These parts are shaded on the schematic diagram.
It is essential that these critical parts should be replaced with manufacturer’s specified parts to prevent shock, fire, or other hazards.
Do not modify the original design without permission of PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY.
It is essential that these critical parts should be replaced with manufacturer’s specified parts to prevent shock, fire, or other hazards.
Do not modify the original design without permission of PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY.
WARNING:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
The user is encouraged to try to correct the interference by one or more of the following measures.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
The user is encouraged to try to correct the interference by one or more of the following measures.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CAUTION :
Any unauthorized changes or modifications to this equipment will void the users authority to operate.
IMPORTANT SAFETY NOTICE
PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE
3
CONTENTS
■ Cover Page
1. Safety Precautions
2. Specifications
2. Specifications
■ SECTION 1 <Service Information>
1. The name of each part
2. Menu Navigation
3. Service Mode
4. External Controls
5. Cautions for Service
2. Menu Navigation
3. Service Mode
4. External Controls
5. Cautions for Service
6. Troubleshooting
■ SECTION 2 <Disassembly Procedures>
1. Parts Location
2. Disassembly Instructions
3. Processing of Lead wire
2. Disassembly Instructions
3. Processing of Lead wire
■ SECTION 3 <Adjustment>
1. Adjustment Procedure
2. Software update procedure
2. Software update procedure
■ SECTION 4 <Schematic Diagrams>
1. Block Diagram
2. Interconnection Block Diagram
3. Schematic Diagram
4. Circuit Boards Diagrams
2. Interconnection Block Diagram
3. Schematic Diagram
4. Circuit Boards Diagrams
■ SECTION 5 <Exploded Views & Replacement Parts List>
1. Exploded Views
2. Replacement Parts List
2. Replacement Parts List
■SECTION 6 <Control Commands List>
PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE
4
1. Safety Precautions
1.1. General Guidelines
·
For continued safety, no modification of any circuit must be
attempted.
attempted.
· Unplug the power cord from the power outlet before
disassembling this projector.
· Use correctly the supplied power cord and must ground it.
· It is advisable to use an isolation transformer in the AC power
line before the service.
· Be careful not to touch the rotation part (cooling fan, etc.) of
this projector when you service with the upper case removed
and the power supply turned ON.
and the power supply turned ON.
· Observe the original lead dress during the service. If a short
circuit is found, replace all the parts overheated or damaged
by the short circuit.
by the short circuit.
· After the service, all the protective devices such as insulation
barriers, insulation papers, shields, and isolation R-C
combinations must be properly installed.
combinations must be properly installed.
· After the service, check the leakage current to prevent the
customer from getting an electric shock.
1.2. Leakage Current Check
1. Prepare the measuring circuit as shown in Fig.1.
Be sure to use a voltmeter having the performance described in
Table 1.
Table 1.
Fig. 1
Table 1
Fig. 2
2. Assemble the circuit as shown in Fig. 2. Plug the power
cord in a power outlet.
3. Connect M1 to T1 according to Fig. 2 and measure the
voltage.
4. Change the connection of M1 from T1 to T2 and measure
the voltage again.
5. The voltmeter must read 0.375 V or lower in both of steps 3
and 4. This means that the current must be 0.75mA or less.
6. If the reading is out of the above standard, the projector
must be repaired and rechecked before returning to the
customer because of a possibility of an electric shock.
customer because of a possibility of an electric shock.
1.3. UV Precaution and UHM Lamp
Precautions
· Be sure to unplug the power cord from the power outlet when
replacing the lamp.
· Because the lamp reaches a very high temperature during its
operation, wait until it cools completely when replacing the
Lamp Unit.
Lamp Unit.
· The lamp emits small amounts of UV-radiation, avoid
direct-eye contact with the light.
· The lamp unit has high internal pressure. If improperly
handled, explosion might result.
· Because the high pressure lamp involves a risk of failure,
never touch the lamp wire lead during the service.