PREFACE
<PT-DZ16K>
Cautions when transporting
When transporting the projector, remove the projection lens before attaching the dust sponge.
  Otherwise dust will accumulate inside and may cause malfunctions.
When transporting the projector, hold it securely by its bottom and avoid excessive vibration and impacts.
  They may damage the internal components and result in malfunctions.
Do not transport the projector with the adjustable feet extended.
  Doing so may damage the adjustable feet.
Do not set up the projector in the following locations.
The projector is designed for indoor use only.
Places where vibration and impacts occur such as in a car or vehicle: Doing so may cause damage to internal
  components or malfunction.
Near the exhaust of an air conditioner: Depending on the conditions of use, the screen may fluctuate in rare cases
  due to the heated air from the air exhaust port or the hot or cooled air. Make sure that the exhaust from the projector
  or other equipment, or the air from the air conditioner does not blow toward the front of the projector.
Places with sharp temperature fluctuations such as near lights (studio lamps): Doing so may shorten the life
  of the lamp, or result in deformation of the outer case due to heat, which may cause malfunctions.
  The operating environment temperature of the projector should be between 0 °C (32 °F) and 45 °C (113 °F) when
  using it at elevations lower than 1 400 m (4 593') above sea level, and between 0 °C (32 °F) and 40 °C (104 °F) when
  using it at high altitudes (between 1 400 m (4 593') and 2 700 m (8 858') above sea level).
  If you use the Smoke cut filter, the operating environment temperature should be between 0 °C (32 °F) and
  35 °C (95 °F). However, it cannot be used at high altitudes.
Near high-voltage power lines or near motors: Doing so may interfere with the operation of the projector.
Places where there is high-power laser equipment: Directing a laser beam onto the lens surface causes damage
  to the DLP chips.
3
p
Note at the time of installation
The high clarity projection lens is thermally affected by the light from the light source, making the focus unstable in
  
the period just after switching on the power. Wait at least 30 minutes with the image projected before adjusting
  the lens focus.
Make sure to set [HIGH ALTITUDE MODE] to [ON] when using the projector at elevations between 1 400 m (4 593')
  and 2 700 m (8 858') above sea level.
  Do not install the projector at elevations of 2 700 m (8 858') or higher above sea level.
Do not use the projector tilted to the right or left.
Do not install and use the projector in portrait setting.
3
PREFACE
<PT-DZ16K>
1. Safety Precautions
2. Specifications
1. The name of each part
2. OSD Menu Navigation
3. Service Mode
4. External Controls
5. Notification for service operation
6. Troubleshooting
1. Parts Location
2. Disassembly Instructions
COVER PAGE
SECTION 1  <SERVICE  INFORMATION>
  CONTENTS
SECTION 2  <DISASSEMBLY  PROCEDURES>
4
2. Disassembly Instructions
3. Wiring
1. Adjustment items and procedure
2. Software update procedure
1. Block Diagram
2. Interconnection Block Diagram
3. Schematic Diagram
4. Circuit Boards Diagram
1. Exploded Views
2. Replacement Parts List
SECTION 5  <Exploded Views & Replacement Parts List>
SECTION 3  <ADJUSTMENTS>
SECTION 4  <SCHEMATIC DIAGRAM>
4
PREFACE
<PT-DZ16K>
1. Safety Precautions
  1.1. General Guidelines
  1.2. Leakage Current Check
1. Prepare the measuring circuit as shown in Fig.1.
    Be sure to use a voltmeter having the performance described in Table 1.
2. Assemble the circuit as shown in Fig. 2. Plug the power cord in a power outlet.
3. Connect M1 to T1 according to Fig. 2 and measure the voltage.
4. Change the connection of M1 from T1 to T2 and measure the voltage again.
5. The voltmeter must read 0.375 V or lower in both of steps 3 and 4.  This means that the current must be 0.75mA
    or less.
6. If the reading is out of the above standard, the projector must be repaired and rechecked before returning to the
    customer because of a possibility of an electric shock.
- For continued safety, no modification of any circuit must be attempted.
- Unplug the power cord from the power outlet before disassembling this projector.
- Use correctly the supplied power cord and must ground it.
- It is advisable to use an isolation transformer in the AC power line before the service.
- Be careful not to touch the rotation part (cooling fan, etc.) of this projector when you service with the upper
  case removed and the power supply turned ON.
- Observe the original lead dress during the service. If a short circuit is found, replace all the parts overheated
  or damaged by the short circuit.
- After the service, all the protective devices such as insulation barriers, insulation papers, shields, and isolation
  R-C combinations must be properly installed.
- After the service, check the leakage current to prevent the customer from getting an electric shock.
to T1
5
 Accuracy : 
 2%
 Input resistance :
 1 MΩ
 Input capactance :
 200 pF
 Frequency range :
15 Hz to 1 MHz
  1.3. UV Precaution and UHM Lamp Precautions
- Be sure to unplug the power cord from the power outlet when replacing the lamp.
- Because the lamp reaches a very high temperature during its operation, wait until it cools completely when replacing
  the Lamp Unit.
- The lamp emits small amounts of UV-radiation, avoid direct-eye contact with the light.
- The lamp unit has high internal pressure. If improperly handled, explosion might result.
- Because the high pressure lamp involves a risk of failure, never touch the lamp wire lead during the service.
Performance
 Voltmeter
 (rms reading)
Table. 1
Fig. 1
Fig. 2
M1
M2
T1
T2
Isolation transformer
to power outlet
Measuring
circuit (Fig.1)
Multi Window
Processor
connection
M1
M2
Rs
Rb
Cs
10 kΩ ±0.1%
V
Vb
(V)
0.022μF
±1.0%
to T1
or T2
in FIG.2
Rs:1500 Ω ±0.1%
Cs:0.22μF ±1.0%
Rb:500 Ω ±0.1%
Weighted lekage current = Vb / 500 (A)
5
PREFACE
<PT-DZ16K>
2. Specifications
  2. 1. Specifications
The specifications of the projector are as follows.
6
6
Page of 9
Display

Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man6) Service Manual ▷ Download

  • DOWNLOAD Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man6) Service Manual ↓ Size: 809.24 KB | Pages: 9 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man6) in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man6) Projector. Information contained in Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man6) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.