DOWNLOAD Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man14) Service Manual ↓ Size: 4.01 MB | Pages: 38 in PDF or view online for FREE

Model
PT-DZ16KU PT-DZ16KE PT-DS16KD (serv.man14)
Pages
38
Size
4.01 MB
Type
PDF
Document
Service Manual / Other
Brand
Device
Projector / 3-CHIP DLP BASED PROJECTOR
File
pt-dz16ku-pt-dz16ke-pt-ds16kd-sm14.pdf
Date

Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man14) Service Manual / Other ▷ View online

SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
INF - 8
INF - 8
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
3. Service Mode
This projector has Service Mode in addition to standard on-screen menus (User Mode).
This mode enables some menu settings for the service operation.
  3. 1. Setting to Service Mode
1. Please push the main body or the menu (MENU) button of the wireless remote controller.
2. Choose a sub menu "service password" of the main menu "projector setup" and push the enter (ENTER) button.
3. Input the password "1565" by remote control and press the ENTER button.
4. Press the MENU button. "SERVICE MODE" (MAIN MENU) will be displayed.
  3. 2. Resetting to User Mode
1. Please push the main body or the menu (MENU) button of the wireless remote controller.
2. Choose a sub menu "service password" of the main menu "projector setup" and push the enter (ENTER) button.
3. Input the password "0000" by remote control and press the ENTER button.
4. Press the MENU button. "USER MODE" (MAIN MENU) will be displayed.
  3. 3. Functions in Service Mode
    3. 3. 1. EXTRA OPTION
EXTRA OPTION is added to bottom in the MAIN MENU.
[ Note ]
Function specification varies according to a version of the main microcomputer software.
1.
2.
3.
INF - 9
  1. LIGHT OUTPUT
Adjusts brightness with Dynamic Iris. It darkens as the value becomes small.
  2. MAX IRIS LEVEL
Adjust the maximum diaphragm quantity of Dynamic iris.  Please do not usually change setting.
When changed an iris unit or a DMD block, please adjust it according to Clause 1 of SECTION 3 (Adjustments).
  3. DYNAMIC GAMMA MODE
Setting of the DYNAMIC GAMMA operation. 
  - ON : Enables Dynamic gamma. (default)
  - OFF : Disables Dynamic gamma.
  4. 3DCMS
  - ON : Enables 3D Color Management system. (default)
  - OFF : Disables 3D Color Management system.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
INF - 9
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
  5. SELF CHECK
Self-diagnosing information Displays.
 SELF CHEC
①-
 MAIN  : R1.00
②-
 SUB   : R1.00
③-
 NT    : R1.00 / 1.00
④-
 OK  AIR TEMP 123/456   OK DMD TEMP 123/456
⑤-
 OK  OUT TEMP 123/456   OK AIR FLOW 123/456/789
⑥-
 OK  LAMP1  12345H  3OM ON
⑦-
 OK  LAMP2  12345H  3OM ON
⑧-
 OK  LAMP3  12345H  3OM ON
⑨-
 OK  LAMP4  12345H  3OM ON
⑩-
 OK  FAN    1111 1111 1111 1111 1111 11
⑪-
 OK  PHOTO SENSOR Y 12345.6
⑫-
 OK  ANGLE SENSOR H -12.34/V +56.78
⑬-
 OK  IRIS
⑭-
 OK  SHUTTER 12345 [   0]
①-
Main microprocessor Software Version
②-
Sub microprocessor Software Version
③-
Network microprocessor Software Version (rootfs/kernel)
④-
Intake air temperature (Celsius/Fahrenheit)
DMD temperature (Celsius/Fahrenheit)
⑤-
Exhaust air temperature (Celsius/Fahrenheit)
Airflow sensor (Sensor value/AD conversion value
⑥-
LAMP1 condition (Cumulative usage time/ON-OFF)
/Correction value)
When the item from 4 to 14 is abnormal last time and shuts it down,
the font of OK becomes red.
INF - 10
(
g
)
)
⑦-
LAMP2 condition (Cumulative usage time/ON-OFF)
⑧-
LAMP3 condition (Cumulative usage time/ON-OFF)
⑨-
LAMP4 condition (Cumulative usage time/ON-OFF)
⑩-
Fan condition (1: normal /0:stop)
  OK FAN
⑪-
Brightness sensor condition
⑫-
Angle sensor condition (Horizontal angle / Vertical angle)
⑬-
Iris Condition
⑭-
Shutter condition (Opening and shutting number of times [Failed number of times])
  6. POWER OFF MESSAGE
Setting of the shutter function with standby operation
  - SHUTTER KEEP: When push the standby key with shutter ON, keep the shutter mode.
  - SHUTTER OPEN: When push the standby key with shutter ON, open the shutter and display 
   the "Power OFF confirmation message". (Default setting)
  7. ERROR OSD
When do not watch the error instructions LED of the lamp by a back projection,
the errors of the lamp can be displayed in the OSD.
  - ON: "Lamp error message" is displayed on OSD.
  - OFF: Does not display the "Lamp error message" in OSD.
  8. CONVERGENCE
When the ingredient of each R/G/B color deviation, revise it electrically.
Specifically, please refer to Clause 1 of SECTION 3 (adjustments).
E
xhaust 
1
E
xhaust 
2
E
xhaust 
3
E
xhaust 
4
Intake 
1
Intake 
2
Lamp 
1
Lamp 
2
Lamp 
3
Lamp 
4
Ba
lla
st 
1
Ba
lla
st 
2
Po
we
r
S
ignal
Lamp 
R
Lamp 
L
Co
lo
r p
rism
 1
Co
lo
r p
rism
 2
P
ump-R
ed
P
ump-Green
P
ump-B
lu
e
Co
lo
r p
rism
 3
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1
1
INF - 10
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
  9. MODEL
Set this when the A-P.C.Board is replaced.
  * If you can copy EEPROM data from the old A-P.C.Board, this setting is unnecessary.
  * This model setting is changed after turn power on and off.
10. CLOG SENSOR CALIBRATION
Proofreading the blocking detect circuit.
  * Execute this after EEPROM(IC3509/IC3518)/A-P.C.Board or clogging sensor (M2-P.C.Board) is replaced.
  * Please refer to Clause 1 of SECTION 3 (Adjustments) for the procedure.
11. LAMP COOLING MODE
Setting of the fan operation for lamp cooling time. 
 - FAN STOP : Lamp fan is stopped at the lamp cooling time.
 - FAN ROTATION : Lamp fan is rotated at the lamp cooling time.
12. SMOKE FILTER DISPLAY
Setting of the self-diagnosis display (U75) at the time of smoked cut-off filter use. 
  - ON : Warning is displayed.
  - OFF : Warning is not displayed.
    3. 3. 2. Additional function of each menu
  1. [PICTURE] menu
AI WINDOW」 is added to the setting of the sub menu "dynamic iris".
    - AI WINDOW: Sets the APL detection area. Please set AI MODE to "AUTO" usually.
  2. [POSITION] menu
DVI EQUALIZER」 is added to a sub menu.
    - DVI EQUALIZER: If noise appears when DVI input, sets the value so that the noise decreases.
      Please set to "AUTO" usually.
INF - 11
      Please set to  AUTO  usually.
  3. [DISPLAY OPTION] menu
The following items are added to setting of sub menu "SDI IN".
XYZ TO RGB SETTING」
    - FACTORY SETTING: Uses the value of FACTORY Yxy conversion factor to the original data of XYZ → RGB.
    (Default)
    - MEASURED: Uses the value of MEASURED Yxy conversion factor to the original data of XYZ → RGB.
    - REC709: Uses the value of REC709 Yxy conversion factor to the original data of XYZ  → RGB.
    - DCI P3: Uses the value of DCI P3 Yxy conversion factor to the original data of XYZ  → RGB.
XYZ TEST PATTERN」
    - WHITE:10%~100%
    - DARK GRAY:1~10
    - COLOR:Red/Green/Blue/Cyan/Magenta/Yellow    1~2
  4. [PROJECTOR SETUP] menu
MAX AVAILABLE LAMPS」 is added to a sub menu.
Sets the maximum number of lamps that can be used. Please set to "4" normally.
DETAILED INFORMATION」 is displayed by pressing the "ENTER" button on the  「BRIGHTNESS CONTROL」 screen.
The detailed information of brightness control can be checked. 
SHUTTER COUNTER」 is added to setting of the sub menu "INITIALIZE".
When the mechanical shutter is replaced, initialize the shutter counter.
The following items are added to an indication screen of the sub menu "STATUS ".
  1) Page 2
- BALLAST VERSION
Ballast software version
  2) Page 3
- HORIZONTAL TILT
Horizontal angle
INF - 11
Page of 38
Display