SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
    5. 2. 3. For detection interlock
Detection by the connector on the rear cover.
If it is not inserted R3-P.C.Board connector (rear cover), power is not turned on.
    5. 2. 4. Replacement of A-P.C. board
When the replacement of A-P.C.Board (assembly) is needed, back up the memory information such as adjustment
data from the old board to PC with the service soft. Then transfer this data to the new A-P.C.Board.
For more information refer to the SECTION 3 "Adjustment". 
(Down load the adjustment software from Projector service web site.)
If you cannot transfer the data that uses the adjustment software, remove IC3508/IC3518 from the original board 
and mount them on the new board.
    5. 2. 5. Replacement of WL-P.C. board
When WL-P.C.Board is replaced, the MAC address of wired LAN will be changed.
Rear cover
R3-P.C.Board
(R31)
INF - 20
When WL P.C.Board is replaced, the MAC address of wired LAN will be changed.
Explain it to the customers in advance.
  5. 3. Replacement of consumable parts
[Attention]
Make sure to turn off the power before replacing the consumable parts.
    5. 3. 1. When to replace the lamp unit
1. The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary 
     to replace it regularly.  The estimated duration before replacement is 3 000 hours.
    However, this may be shortened depending on individual lamp characteristics, usage conditions, and the
    installation environment. Therefore, it is strongly recommended that a replacement lamp unit be prepared.
2. To predict when to replace the lamp, check the lamp cumulative operating hours displayed in lamp1-4 of "STATUS".
3. The unit can damage the projector if it has not been replaced after 3 000 hours of usage. 
    Thus, the lamp automatically turns off after approximately ten minutes.
    If the cumulative operating time of all 4 lamp unit bulbs exceeds 3 000 hours, the power will be switch off after 
    about 10 minutes.
The runtime of 3 000 hours is a rough estimate and is not guaranteed.
[Note]
INF - 20
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
    5. 3. 2. Replacement procedure for lamp unit
1. Power off the projector and disconnect the power plug from the power outlet. 
    And wait at least one hour, and then check if the lamp unit has been cooled down.
2. Loosen the lamp unit cover fixing screw (one screw) until it turns freely, and then open the lamp unit cover 
    in the direction of the arrow.
3. Loosen the lamp case fixing screws (two screws each) until they turns freely, 
    and then hold the lamp case handles, pull out backward.
Rear cover
Rear cover fixing screw
Open a little
Slide it in the direction of the arrow, and then pull it out backward to remove.
Lamp case R handle
Lamp case L Lamp case R
Lamp case L
handle
INF - 21
4. Loosen the lamp unit fixing screws (two screws each) until they turns freely, and then pull out the lamp unit 
    from the projector.
5. Install the Lamp units and reverse the disassembly procedures, install the rear cover.
Projector does not turn on by protection circuit, if Lamp unit or rear cover are incompletely-installed.
If the lamp unit or lamp case is not installed properly, remove it and then gently install it again.
Pushing it in forcibly or exerting excessive force may break the connector.
When you place the new lamp unit, the projector resets the total usage time of the lamp unit automatically.
[Attention]
When you loosen the lamp case fixing screws with the projector installed upward in the vertical direction,
the lamp case may drop off on its weight
Lamp case L
Lamp case R
Lamp
unit 1
Lamp
unit 2
Lamp
unit 3
Lamp
unit 4
Lamp unit fixing screws
Lamp unit
Lamp unit
Lamp unit fixing screws
Lamp case handle
Lamp case fixing screws
the lamp case may drop off on its weight. 
Be sure to hold the lamp case handle when you loosen the lamp case fixing screws.
INF - 21
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
    5. 3. 3. Air filter maintenance
1. The air filter is clogged with dust, causing the filter replacement message to appear on the screen and 
     the filter indicator <FILTER> to light in red.  In such a case, clean the air filter unit.
2. The proceeds of the air filter clogging, becomes hot of projector inside, and <TEMP>indicator is lit , power shut down.
    Then <FILTER>Indicator remains red , <TEMP> indicator will flash (twice) red.
3. Indication of cleaning is 10,000 hours. but varies greatly depending on the usage environment.
    If dirt does not come off even if the unit is maintained, it is time for the unit to be replaced.
    5. 3. 4. Cleaning procedure for Air filter unit
1. Make sure to turn off the power before replacing the air filter unit.
2. Loosen the lamp unit cover fixing screw (one screw) until it turns freely, then remove the Air filter cover, 
    pull out the air filter unit.
3. Clean and dry the air filter unit.
1) Soak the air filter unit in cold or warm water and then lightly rinse it.
Do not use cleaning tools such as brushes.
2) Rinse the unit two to three times using fresh water each time.
Air filter unit
Air filter cover
Air filter cover fixing screw
INF - 22
3) Let the unit naturally dry off in a well-ventilated place where there is 
    little dust and the unit is protected from direct sunlight.
Make sure that it is sufficiently dry before reinstalling it to the projector.
Do not dry using drying devices such as dryers.
(Please read the page "Maintenance/Replacement" on the instruction book to know about details.)
4. After cleaning the air filter unit, install the filter unit and the air filter cover.
The air filter unit has no difference between top and bottom, but is two-sided. 
Match the protrusion position of the air filter with the grooves on the projector body.
  5. 4. Initialization for control device password
To revert to the factory default password (AAAA), perform the following operations while the screen asking
for a control device password input is displayed.
1. Press the <AUTO SETUP> button on the remote control or control panel for at least two seconds.
2. Press ▼ for at least two seconds.
Groove on the projector body
Protrusion of the air filter unit
Air filter unit
INF - 22
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
6. Troubleshooting
  6. 1. Shutdown system
*1:Different values by "number of lamp lit", or "Fan mode", "direction of installation"
Bimetallic Thermostat (Manual reset type)
 ⇒
 152 ℃ or more (G-P.C.B  G24)
Check the installation
environment
Ventilation holes are blocked
STANDBY/ON
Blinks in red 3 times
STANDBY/ON
Blinks in red 1 times
Measured value of Optical module
temperature sensor ⇒ More than 65 ℃ *1
F91/F92
U23
(U13)
H13
U21
(U11)
U24
(U14)
H12
U22
(U12)
Measured value of Exhaust air temperature
sensor ⇒ Below -20 ℃
H11
No response after FPGA configuration
(F91⇒FPGA1/F92⇒FPGA2)
OSD warning, etc
Measured value of Optical module
temperature sensor ⇒ More than 55 ℃ *1
TEMPERATURE
WARNING」
(Warning:TEMP Red
lights)
Measured value of Intake air temperature
sensor ⇒ Below -20 ℃
Interlock SW status
Open more than 1 second (R3-P.C.B  P31)
Measured value of Intake air temperature
sensor ⇒ 48℃ or more
(High altitude:43℃ / Smoke cut:38℃)
Measured value of Optical module
temperature sensor
After power-on, Is below 5 ℃ for more than
5 minutes.
Shutdown detection
Exhaust fan is deterioration,
abnormal
Ventilation holes are blocked
At highlands, high altitude mode
is not set
TEMPERATURE
WARNING」
(Warning:TEMP Red
lights)
TEMPERATURE
WARNING」
(Warning:TEMP Red
lights)
Ballast block: heatsink
Sensed temperature (RT1): 100~110℃
Probable cause
Bad connection of each
P.C.Board connector
Intake air temperature sensor
bad connection
Exhaust air temperature sensor
bad connection
Indicator indication
STANDBY/ON
Red lights
TEMP
Red lights
Not lighting or flashing
U91
TEMP
Blinks in red 2 times
High temperature of
environment
Ventilation holes are blocked
Intake air temperature sensor
abnormality
Usage environment temperature
is lower than the rated
Blown out of the fuse
( with some reason )
Rear cover is not installed
Inductor clogging
Something wrong with Ballast
block
Optical module temperature
sensor bad connection
Abnormal installation or
deterioration of liquid cooling
module
Ventilation holes are blocked
At highlands, high altitude mode
is not set
Self-diagnosis
Power fuse <K-P.C.B>
F9001/F9002(10A/250V)
Measured value of Optical module
temperature sensor ⇒ Below -20 ℃
INF - 23
Page of 38
Display