SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
5. Cautions for service
  5. 1. Before service operation
    5. 1. 1. Lamp
1. Contact the dealer to purchase a replacement lamp unit.
2. A Phillips screwdriver is necessary when replacing the lamp unit.
3. Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object. Please handle with care.
4. The lamp may be burst. Replace the lamp unit carefully so that the broken pieces of the lamp glass will not scatter. 
    When the projector is mounted on the ceiling, do not make the replacement directly under the lamp unit or put your
    face near it.
5. When disposing of used lamp units, contact your local authorities for correct methods.
    5. 1. 2. Air filter unit
1. Contact the dealer to purchase a replacement air filter unit.
2. A Phillips screwdriver is necessary when replacing the air filter unit.
3. Air filter replacement is recommended after cleaning the unit two times.
    The dust-proof properties may be reduced after each cleaning.
[Caution]   When used the "Smoke cut filter", please enter the password and change the filter type settings.
When use is finished, return the filter settings to "NORMAL".
* For more information, please refer to the operating instructions of the smoke cut filter.
    5. 1. 3. Lithium battery
1. The lithium battery is used for the internal clock in the A-P.C. board. So when it consumed it must be replaced.
2. After replacing the lithium battery, set the "Date and Time" on the sub-menu which in main menu "projector set up".
    5. 1. 4. About use by vertical upwards / downward settings
This unit, clasp attached conditions to lamp case according to  Installation mode is different from PT-DZ21K series. 
It is necessary at all times regardless of the installation mode.
・ Clasp mounting correspondence table of each installation mode
* It becomes the cause that it hastens the life of the lamp when use it as wrong setting.
Vertical down setting
Lamp case L / R
Lamp case R
[Note]   Factory default, since clasps are attached to two places of each lamp case, please do not remove.
Nonuse
Ceiling setting
Lamp case L / R
Nonuse
Vertical up setting
Lamp case L / R
Lamp case L
    Replacement lamp unit  ET-LAD510 (1bulb)/ ET-LAD510F (4 bulbs)
Lithium battery : CR2032
[Attention]  Please be sure to read the warnings and notices on the lamp that is described in the Operating Instructions.
                    "Read this first!",  "Precautions for use", "Maintenance/replacement"
            Model
Installation mode
PT-DZ16K
< Reference >
PT-DZ21K series
Floor setting
Lamp case L / R
Model Number
Service Password
Filter Type setting
Self-diagnosis display
Reference
ET-SFR510
1111
SPECIAL
U75
Option Accessory
TXFKN01VKR9
1016
SPECIAL2
U79
Service parts (High functionality type)
Note: Use only specified lamp units.
*Use only specified lithium battery
Air filter unit : ET-EMF510
INF - 18
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
[ Attention ]
You can see the hole in the top of the lamp case 
whether the clasps are attached or not.
  5. 2. Service
    5. 2. 1. Supporting Methods
The basic service policy is shown below.
PC-P.C.Board
・ H
-P.C.Board
・ B
-P.C.Board
・ MR
-P.C.Board
・ WF
-P.C.Board
・ M1
-P.C.Board (Intake/Exhaust)
・ WL
-P.C.Board
・ M2
-P.C.Board
Repair contents
Applied parts
[ Lamp case L ]
Clasps are attached 
[ Lamp case R ]
INF - 19
・ RM
-P.C.Board
・ M3
-P.C.Board
・ RW
-P.C.Board
・ EL
-P.C.Board
・ R3
-P.C.Board
・ ER
-P.C.Board
・ LL
-P.C.Board
・ LR
-P.C.Board
Lens mount
Mechanical shutter
Analysis mirror
Iris unit
    5. 2. 2. Repair
1. Since this projector is very strong light output, when checking the projection screen, please UV protection glasses
     and select to "single" lamp mode.  If the projection distance is short, please pay particular attention.
2. When electrifying the projector for the check and adjustment at top case remove, the strong light emits from the 
    lighting cover and its around.  Please take the use of UV protection glasses and means of the shading.
3. While the fan is working, do not pull the plug out nor disconnect the breaker.
* This model is not equipped with a function "Direct Power Off".
* When the monitor of power supply lamp turns red and the fan stops, disconnecting can be done.
4. Be sure to unplug the power cord from the power outlet before repair.
* When replacing the print board, the internal electrical parts can be broken by the static electricity of clothes or
  human body. Be careful of static electricity and wear the anti-static electricity gloves.
5. After the service or the repair is completed, confirm the operation of the product is normal.
6. Do handling and safekeeping carefully because the user setup information remains in the projector.
 Replaced by discrete
 components
        Other electrical parts and mechanism parts
  Block replacement
  P.C.Board replacement
        DMD Block
 Repair at the factory
INF - 19
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
    5. 2. 3. For detection interlock
Detection by the connector on the rear cover.
If it is not inserted R3-P.C.Board connector (rear cover), power is not turned on.
    5. 2. 4. Replacement of A-P.C. board
When the replacement of A-P.C.Board (assembly) is needed, back up the memory information such as adjustment
data from the old board to PC with the service soft. Then transfer this data to the new A-P.C.Board.
For more information refer to the SECTION 3 "Adjustment". 
(Down load the adjustment software from Projector service web site.)
If you cannot transfer the data that uses the adjustment software, remove IC3508/IC3518 from the original board 
and mount them on the new board.
    5. 2. 5. Replacement of WL-P.C. board
When WL-P.C.Board is replaced, the MAC address of wired LAN will be changed.
Rear cover
R3-P.C.Board
(R31)
INF - 20
When WL P.C.Board is replaced, the MAC address of wired LAN will be changed.
Explain it to the customers in advance.
  5. 3. Replacement of consumable parts
[Attention]
Make sure to turn off the power before replacing the consumable parts.
    5. 3. 1. When to replace the lamp unit
1. The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary 
     to replace it regularly.  The estimated duration before replacement is 3 000 hours.
    However, this may be shortened depending on individual lamp characteristics, usage conditions, and the
    installation environment. Therefore, it is strongly recommended that a replacement lamp unit be prepared.
2. To predict when to replace the lamp, check the lamp cumulative operating hours displayed in lamp1-4 of "STATUS".
3. The unit can damage the projector if it has not been replaced after 3 000 hours of usage. 
    Thus, the lamp automatically turns off after approximately ten minutes.
    If the cumulative operating time of all 4 lamp unit bulbs exceeds 3 000 hours, the power will be switch off after 
    about 10 minutes.
The runtime of 3 000 hours is a rough estimate and is not guaranteed.
[Note]
INF - 20
SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
    5. 3. 2. Replacement procedure for lamp unit
1. Power off the projector and disconnect the power plug from the power outlet. 
    And wait at least one hour, and then check if the lamp unit has been cooled down.
2. Loosen the lamp unit cover fixing screw (one screw) until it turns freely, and then open the lamp unit cover 
    in the direction of the arrow.
3. Loosen the lamp case fixing screws (two screws each) until they turns freely, 
    and then hold the lamp case handles, pull out backward.
Rear cover
Rear cover fixing screw
Open a little
Slide it in the direction of the arrow, and then pull it out backward to remove.
Lamp case R handle
Lamp case L Lamp case R
Lamp case L
handle
INF - 21
4. Loosen the lamp unit fixing screws (two screws each) until they turns freely, and then pull out the lamp unit 
    from the projector.
5. Install the Lamp units and reverse the disassembly procedures, install the rear cover.
Projector does not turn on by protection circuit, if Lamp unit or rear cover are incompletely-installed.
If the lamp unit or lamp case is not installed properly, remove it and then gently install it again.
Pushing it in forcibly or exerting excessive force may break the connector.
When you place the new lamp unit, the projector resets the total usage time of the lamp unit automatically.
[Attention]
When you loosen the lamp case fixing screws with the projector installed upward in the vertical direction,
the lamp case may drop off on its weight
Lamp case L
Lamp case R
Lamp
unit 1
Lamp
unit 2
Lamp
unit 3
Lamp
unit 4
Lamp unit fixing screws
Lamp unit
Lamp unit
Lamp unit fixing screws
Lamp case handle
Lamp case fixing screws
the lamp case may drop off on its weight. 
Be sure to hold the lamp case handle when you loosen the lamp case fixing screws.
INF - 21
Page of 38