DOWNLOAD Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man13) Service Manual ↓ Size: 44.48 MB | Pages: 110 in PDF or view online for FREE

Model
PT-DZ16KU PT-DZ16KE PT-DS16KD (serv.man13)
Pages
110
Size
44.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / 3-CHIP DLP BASED PROJECTOR
File
pt-dz16ku-pt-dz16ke-pt-ds16kd-sm13.pdf
Date

Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man13) Service Manual ▷ View online

SECTION 2  DISASSEMBLY  PROCEDURES
<PT-DZ16K>
  3. 5. RL-P.C.Board
* Reliably insert the four corners
* Note to pinch the lead wire
Dustproof sheet
* Clamp
・RL8-Color prism 1 fan
DIS-23
・RL8-Color prism 1 fan
・RL14-M31(Brightness sensor)
* Through the cutout
* Clamp
・RL13-H1
RL8
RL14
* Line hook
・RL15-Intake 1 fan
・RL16-Intake 2 fan
・RL10-M11
・RL17-SW(Filter detection)
RL17
RL10
RL16
RL15
* Line hook
・R
L10
M1
1
・R
L17
SW
(Fi
lter detection)
* Cl
a
m
p
・R
L11
LL1
RL11
* Clamp
・RL1-G13
・RL7-Lamp R fan
・RL12-LR1
RL1
RL7
RL12
RL13
* L
in
・R
・R
DIS-23
SECTION 2  DISASSEMBLY  PROCEDURES
<PT-DZ16K>
  3. 6. RM-P.C.Board
  3. 7. Lamp fan
* Through the cutout in the sheet
・RM3-Motor (focus)
・RM6-Position SW
・RM7-Motor (H shift)
* Clamp
・Lamp 1 fan-RL4
* Through the cutout in the sheet
・RM2-Motor (V shift)
・RM5-Shutter
・RM6-Position SW
* Through the cutout
in the sheet
・RM1-G12
RM5
RM2
RM6
* Clamp
・Liquid cooling pipe
* Liquid cooling pipe
fixed in sheet
RM3 RM7
RM1
* Not good through the square holes of sheet
(To be wired from the top of sheet)
DIS-24
Lamp 3 fan
RL2
RL3
RL4
RL5
* Clamp
・Lamp 1 fan-RL4
・Lamp 2 fan-RL5
・Lamp 3 fan-RL2
・Lamp 4 fan-RL3
* Remainder of wire(RL3/RL4), folded back to clamp
*Bundle up all wires
with a sheet
Lamp 4 fan
Lamp 2 fan
Lamp 1 fan
DIS-24
1. Adjustment item and a procedure
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ ADJ-2
1. 1. Lighting area adjustment
1. 2. Electrical convergence adjustment  (*Effective in the DW17K)
1. 3. Lens calibration
1. 4. EEPROM data transfer
1. 5. Model information setup
1. 6. Clog sensor calibration
1. 7. Contrast adjustment
2. Software Update procedure  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ ADJ-9
2. 1. Update by the LAN terminal connection
2. 2. Update by the SERIAL terminal connection
CONTENTS
SECTION 3
ADJUSTMENTS
Model No.
PT-DZ16KU
PT-DZ16KE
PT-DZ16KD
SECTION 3  ADJUSTMENTS
<PT-DZ16K>
1. Adjustment item and a procedure
When the following components are replaced, adjust each item according to the table below.
  1. 1. Lighting area adjustment
    1. 1. 1. Confirmation of the lighting area
1. After replacing the DMD block or each Analysis block part, 
    check if any shade is visible in the DMD effective display area.
* Make the projection environment as dark as possible and project an all-white
  and all-black pattern (internal test pattern) to conduct this check.
2. When the Lighting area interferes with the effective area, adjust the 
    Relay Lens Holder.
    1. 1. 2. Adjustment procedure of the Lighting area
 1.4. EEPROM data transfer
 1.6. Clog sensor calibration
 A-P.C.Board
 Save data to a PC before A-P.C.B exchange once and
 write in the data which saved at a new A-P.C.B.
 G-P.C.Board / M2-P.C.Board
 1.5. Model information setup
 A-P.C.Board
 When "1.4 EEPROM data transmission" was finished,
  it is not necessary.
 DMD Block / Iris unit
 DMD block / Each Analysis block part
Replaced Component
Remarks
Adjustment Item
 1.1. Lighting area adjustment
 DMD block
 Stepper motor (H/V/F)
 When a power supply was cut during shift / focus
movement, carry it out.
 1.2. Electrical convergence adjustment
 1.3. Lens calibration
 1.7. Contrast adjustment
Lighting area
Effective area
ADJ - 2
    1. 1. 2. Adjustment procedure of the Lighting area
1. Select the "QUAD" of [LAMP SELECT], projection the "APL30%" of [TEST PATTERN].
2. Loosen the 2 fixed screw with a hexagon wrench (2.5mm).
3. 1) In advance, adjust the adjustment screw that lighting
         area adjustment bracket clearance becomes 6mm.
    2) Adjustment groove, must have adjusted to the center.
4. The "Adjustment screw" is adjustment the horizontal
     direction of the Lighting area.
* The Lighting area moves to the rightward when turn
  a screw in the clockwise.
5. The "Adjustment groove" is adjustment the vertical
    direction of the Lighting area.
* The Lighting area moves to the under when turn
  in the clockwise.
6. After adjustment completion, tighten two "fixed screw".
Adjustment
groove
Adjustment
screw
Fixed
screw
6mm
Lighting area
Effective area
Adjustment screw
Adjustment groove
ADJ - 2
Page of 110
Display

Click on the first or last page to see other PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man13) service manuals if exist.