6-2
6.2 Installation procedure
Please keep this procedure (It is not printed in the Service Manual).
Remove all shipping materials before installation.
Caution: Make sure the copier is unplugged before the installation.
Remove the original guide plate of
the copier.
1
Location
Shipping material / Procedure
Check
2
Application of the anti-electrostatic liquid
(1) Clean the Plate glass before
application.
(2) Apply (10cc) to a soft pad folded in half.
(3) Uniformly wipe the platen glass in
a lateral direction.
(4) Leave the platen glass for 10
minutes or longer, before handling.
3
Install the hinge positioning
screw.
(2 shoulder screws)
4
Installation of magenet catch plate.
(1) Remove right cover (upper).
(2) Remove the platen glass.
(3) Install the magnet catch plate to the
notches in the control panel.
(4) Reassemble in the reverse order.
Note: Use shorter screws to fix the
original guide plate.
SU001
1
3
3
4
6
6
6
5
6
8
7
2
SU008
Upper Rear Cover
6-3
 Installation
Installation of ADF
(1) Place the ADF on the copier.
(2) Slide the hinges forward.
(The screws mentioned above fit
into the holes of both hinges.)
(3) Fix both hinges of the ADF by
tightening the hinge mounting
screws.
       * Install the hinge positioning
screws at the center of the
hinge holes.
5
Location
Shipping material / Procedure
Check
6
Installation of Original Feed Tray.
(1) Connect the connector.
(2) Install the original feed tray. (2
screws)
       * Do  not  pinch  the  harness
when installing the original
feed tray.
SU002
1
2
2
SU003
3
2
1
1
Hinge
positioning
screw
6
Connect the ADF harness to the
copier ADF connector.
SU007
Copier ADF Connector
6-4
6.3 Adjustment
Height adjustment
Only required if the gap between the
platen glass and rubber spacer is over
0.5mm.
(See bottom figure)
a) Remove the top right cover of the
copier. (2 screws)
b) Remove the top left cover of the
copier. (2 screws)
c) Remove the original guide plate
of the copier. (3 screws)
(1) Remove the transport belt unit.
a) Open the ADF to the service
position.
(90 degrees)
b) Remove the 2 screws on the
upper frame. (See top figure)
c) Remove the transport belt unit.
(2) Place the transport belt unit on the
platen glass. (See the figure on the
left)
Note: Make sure to align the
magnet with the magnet
catches.
(3) Loosen the fixing screws. (4 screws)
(Left and right)
(4) Adjust the position of the magnets
so the gap between the platen glass
and the rubber spacer is less than
0.5mm.
(Right and left side)
(5) Reassemble in the reverse order.
1
Location
Shipping material /Procedure
Check
SU009
Transport belt unit
Fixing screw
(Left side)
Platen Glass
Rubber
spacer
Magnet
Magnet cartch
Fixing screw
(Right side)
Rubber spacer
Magnet
Magnet cartch
2
2
SV011
SV010
6-5
 Installation
Original side to side adjustment
Note: Make sure the copier is
adjusted correctly before
making this adjustment.
(1) Loosen the original feed tray
adjusting screws (2 screws), and
move the tray front or rear as
required, then tighten the screws.
2
Location
Shipping material / Procedure
Check
3
Original skew adjustment
Note: Make sure the copier is
adjusted correctly before
making this adjustment.
(1) Open the ADF.
(2) Loosen the ADF hinge mounting
screw.
(Right side)
(3) Move the ADF in "A" or "B" direction
as required, then tighten the screw.
Copy A: Move the ADF in "A" direction.
Copy B: Move the ADF in "B" direction.
SU005
SU010
1
1
2
2
A
B
ADF hinge (Right)
Hinge fixing screw
Copy
Copy
Page of 64