20
7.11. Remove the SS3-Board
1. Disconnect the connector (SS03) and disconnect the flex-
ible cable (SS57).
2. Remove the screws (
×2 
) and remove the SS3-Board. 
7.12. Remove the SS-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (SS02 and SS03).
3. Disconnect the connectors (SS11, SS12, SS23 and
SS34).
4. Disconnect the flexible cables (SS54 and SS55).
5. Remove the molding prop (
×1 ).
6. Remove the screws (
×5 
) and remove the SS-Board.
7.13. Remove the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered)
with the Plasma panel surface facing downward.
2. Remove the Stand brackets (L, R) fastening screws (
×5
 each) and remove the Stand brackets (L, R).
7.14. Remove the C1-Board
1. Remove the tuner unit. (See section 7.4.)
2. Remove the Stand bracket R. (See section 7.13.)
3. Remove the flexible cables holder fastening screws (
×10
).
4. Disconnect the flexible cables (CB1, CB2, CB3, CB4 and
CB5).
5. Disconnect the flexible cables (C10 and C11).
6. Remove the screws (
×6 
) and remove the C1-Board.
21
7.15. Remove the C2-Board
1. Remove the tuner unit. (See section 7.4.)
2. Remove the stand bracket L. (See section 7.13.)
3. Remove the flexible cables holder fastening screws (
×6
).
4. Disconnect the flexible cables (CB6, CB7 and CB8).
5. Disconnect the flexible cables (C20 and C21).
6. Disconnect the connector (C22).
7. Remove the screws (
×4 
) and remove the C2-Board.
7.16. Remove the C3-Board
1. Remove the tuner unit. (See section 7.4.)
2. Remove the flexible cables holder fastening screws (
×6
).
3. Disconnect the flexible cables (CB9, CB10 and CB11).
4. Disconnect the flexible cable (C32).
5. Disconnect the connector (C33).
6. Remove the screws (
×4 
) and remove the C3-Board.
7.17. Remove the Front bracket
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (A51). (See section 7.4.)
3. Remove the screws (
×2 , 
×2 
) and remove the
Front bracket.
7.18. Remove the G-Board
1. Remove the Front bracket. (See section 7.17.)
2. Remove the screws (
×2 ).
3. Remove the Front shield case front.
4. Disconnect the connectors (G51). 
5. Remove the screws (
×3 ).
6. Remove the G-Board.
7.19. Remove the Speakers
1. Disconnect the relay connectors
2. Remove the screws (
×4 
 each) and remove the
Speaker (L, R).
22
7.20. Remove the Plasma panel sec-
tion from the Cabinet assy
(glass)
1. Remove the stand brackets (left, right) fastening screw
(
×1  
each).
2. Remove the cabinet assy and the plasma panel fastening
screws (
×8 ).
3. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
4. Remove the spacers and spacer rings (
×6 ).
23
Caution:
• Please confirm the installation place of BC hook (L, R)
Spacer and Spacer Ring when you exchange the Plasma
panel, and install BC hook (L, R) Spacer and Spacer Ring in
an original installation place after exchanging the Plasma
panel.
7.21. Remove the S-Board
1. Remove the Cabinet assy. (See section 7.20.)
2. Disconnect the connector (S1).
3. Remove the screws (
×2 
) and remove the S-Board
metal frame.
4. Remove the screws (
×2 
) and remove the S-Board.
7.22. Remove the K-Board
1. Remove the Cabinet assy. (See section 7.20.)
2. Remove the S-Board. (See section 7.21.)
3. Remove the screws (
×2 ).
4. Disconnect the connector (K1) and Remove the K-Board.
7.23. Replace the plasma panel (fin-
ished)
1. Place the new plasma panel (finished) on the flat surface
of the table (covered by a soft cloth), with the plasma
panel surface facing downward.
2. Attach the C1-Board, C2-Board and the C3-Board, con-
nect the flexible cables (
×11) from the plasma panel to the
C1-Board, C2-Board and the C3-Board, and fit the flexi-
ble cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow 
any debris, dust or handling residue to remain 
between the front glass and plasma panel.
Page of 127