Panasonic TH-R42PY8KS Service Manual / Other ▷ View online
ORDER NO.PCZ0808109AE
Plasma Television
Model No.
TH-R42PY8KS
GPF11DE Chassis
Please file and use this manual together with the service manual for Model No.
TH-42PY8P, ORDER NO. PCZ0805044CE.
TH-42PY8P, ORDER NO. PCZ0805044CE.
2
1 Different points
1.1.
Mechanical Replacement Parts List
1.2.
Electrical Replacement Parts List
Ref. No.
Parts No.
Parts name & Description
Remarks
TH-42PY8P
TH-R42PY8KS
6
TBLA3632
TBLA3626
STAND POLE (R)
7
TBLA3633
TBLA3627
STAND POLE (L)
8
TBLX0053
TBLX0075
STAND BODY ASY
PAVCCZ
9
TBX0E84101
TBX0E84102
POWER BUTTON
PAVCCZ
THEL062N
THEL061N
SCREW
PAVCCZ
14
TKKC5342
TKKC5348
LED PANEL
PAVCCZ
15
TKP0E27902
TKP0E27903
DOOR
PAVCCZ
16
TKP0E35804
TKP0E35805
SPEAKER PANEL (LEFT)
PAVCCZ
17
TKP0E35902
TKP0E35903
SPEAKER PANEL (RIGHT)
PAVCCZ
TKP0E36202
TKP0E36203
SIDE COVER
PAVCCZ
29
TPC0E47200
TPC0E52300
CARTON BOTTOM
PAVCCZ
30
TPC0E49801B
TPC0E52202
CARTON TOP
PAVCCZ
31
TPD0E1053
TPD0E1066
CUSHION TOP SIDE
PAVCCZ
32
TPD0E2006
TPD0E2039
PEDESTAL CUSHION
PAVCCZ
33
TPD0E2026
TPD0E2041
CUSHION BOTTOM SIDE
PAVCCZ
34
TPD0E9121
TPD0E9144
TOP PAD
PAVCCZ
35
TPD0E9137
TPD0E9143
ACCESSORIES PAD
PAVCCZ
41
TQB0E0609*
- - - - -
INSTRUCTION BOOK
(EACH LANGUAGE)
(EACH LANGUAGE)
PAVCCZ
41
- - - - -
TQB0E0632L
INSTRUCTION BOOK (RUSSIAN)
PAVCCZ
42
TTU0E0326
TTU0E0342
REAR COVER
PAVCCZ
45
TXFKY01RUTE
TXFKY01SQTR
CABINET ASSY
PAVCCZ
Ref. No.
Parts No.
Parts name & Description
Remarks
TH-42PY8P
TH-R42PY8KS
PCB
TZTNP01RUTE
A-R42PY8KS
CIRCUIT BOARD A
PAVCCZ
PCB
TXNGS1RWTB
TXNGS1SUTR
CIRCUIT BOARD GS
PAVCCZ
PCB
TNPA4411AC
TXNSS1SMTR
CIRCUIT BOARD SS
PAVCCZ
PCB
TXN/K1RRTE
TXN/K1SRTR
CIRCUIT BOARD K
PAVCCZ
PCB
TXN/S1RRTB
TXN/S1SRTR
CIRCUIT BOARD S
PAVCCZ
© 2008 Matsushita Electric Industrial Co., Ltd. All
rights reserved. Unauthorized copying and distribu-
tion is a violation of law.
rights reserved. Unauthorized copying and distribu-
tion is a violation of law.
ORDER NO. PCZ0805044CE
Plasma Television
Model No.
TH-42PY8P
TH-42PZ8B
TH-42PZ8E
TH-42PZ8B
TH-42PZ8E
GPF11DE Chassis
2
1 Safety Precautions
1.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
4. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.2.
Touch-Current Check
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground
2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground
such as a water pipe, as shown in Figure 1.
3. Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reserve the AC plug in the AC outlet and repeat each of the above measure.
6. The potential at any point (TOUGH CURRENT) expressed as voltage U
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reserve the AC plug in the AC outlet and repeat each of the above measure.
6. The potential at any point (TOUGH CURRENT) expressed as voltage U
1
and U
2
, does not exceed the following values:
For a. c.: U
1
= 35 V (peak) and U
2
= 0.35 V (peak);
For d. c.: U
1
= 1.0 V,
Note:
The limit value of U
2
= 0.35 V (peak) for a. c. and U
1
= 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 2.0
mA d. c.
The limit value U
The limit value U
1
= 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 kHz.
7. In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the customer.
Figure 1