DOWNLOAD Panasonic TH-R42PV8KS Service Manual ↓ Size: 25.53 MB | Pages: 127 in PDF or view online for FREE

Model
TH-R42PV8KS
Pages
127
Size
25.53 MB
Type
PDF
Document
Service Manual / Other
Brand
Device
Plasma / GPH11DE CHASSIS
File
th-r42pv8ks.pdf
Date

Panasonic TH-R42PV8KS Service Manual / Other ▷ View online

9
• This equipment complies with the EMC standards listed below.
EN55013, EN61000-3-2, EN61000-3-3, EN55020.
10
5 Service Mode
5.1.
How to enter into Service Mode
While pressing [VOLUME ( - )] button of the main unit, press [0] button of the remote control three times within 2 seconds.
5.1.1.
Key command
 [1] button...Main items  Selection in forward direction
 [2] button...Main items  Selection in reverse direction
 [3] button...Sub items  Selection in forward direction
 [4] button...Sub items  Selection in reverse direction
 [RED] button...All Sub items  Selection in forward direction
 [GREEN] button...All Sub items  Selection in reverse direction
 [VOL] button...Value of sub items change in forward direction ( + ), in reverse direction ( - )
11
5.1.2.
Contents of adjustment mode
• Value is shown as a hexadecimal number.
• Preset value differs depending on models.
• After entering the adjustment mode, take note of the value in each item before starting adjustment.
5.1.3.
How to exit
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
12
5.2.
Service tool mode
5.2.1.
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
5.2.2.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication will be cleared by [Self-check indication and forced to factory shipment setting].
5.2.3.
POWER ON TIME/COUNT
To display TIME/COUNT menu, highlight position, then press MUTE for 3sec. 
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of On times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command. 
5.2.4.
Exit
1. Disconnect the AC cord from wall outlet or switch off the power with the [POWER] button on the main unit.
Page of 127
Display