Panasonic TH-50PF11EK Service Manual ▷ View online
10
TH-50PF11EK
GPF11D chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful
for special function required customers. This should be set at the installation stage.
Note:
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R” button on the remote control and hold for more than 5 seconds.
The “SHIPPING“ menu is displayed and the lock is released when it disappears.
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R” button on the remote control and hold for more than 5 seconds.
The “SHIPPING“ menu is displayed and the lock is released when it disappears.
Option Menu for GPF11D series
Option menus
default setting
Contents
Weekly Command Timer
---
Sets Weekly Command Timer.
Onscreen display
On
Enable/Disable to display input mode indication after power on and no signal
indication.
indication.
Initial INPUT
Off
Sets the initial input mode when the power is turned on. Allow input mode selec-
tion while power is on.
tion while power is on.
Initial VOL level
Off
Sets the initial volume level when the power is turned on. Allow Volume control
while power is on.
while power is on.
Maximum VOL Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input
mode by input selection key.
mode by input selection key.
Button lock
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume up/
down)
down)
Remocon User Level
Off
Remote key invalidation.
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Sur-
round, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Sur-
round, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Off-timer function
Enable
Off-timer operation Enable/Disable.
Initial Power Mode
Normal
Sets the power mode of the unit for when the power recovers from failure or
after plugging off and in again.
after plugging off and in again.
ID select
0
Set ID number from 0 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
Off
Serial ID function On/Off
Display size
Off
Display size function On/Off
Studio W/B
Off
Studio W/B function On/Off
Studio Gain
Off
Studio Gain function On/Off
Slot power
Off
Sets the slot power mode while the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
Allow Optional Terminal Board insert Slots while power is on.
Power On Screen Delay
Off
You can set the power-on delay time of the displays to reduce the power load,
when you press
to turn on the multiple displays that are set together, for
example, on MULTI DISPLAY system.
Set each display’s setting individually.
Set each display’s setting individually.
Clock Display
Off
Clock Display function On/Off.
All Aspect
Default
Aspect mode: default/All aspect mode.
Rotate
Off
Rotate function On/Off
Serial Slot Select
Slot1
Selects the slot which communicates serial.
Note: The setting of an external command can be set only from the fixed serial
terminal.
Note: The setting of an external command can be set only from the fixed serial
terminal.
11
TH-50PF11EK
6 Service Mode
6.1.
CAT (Computer Aided Test) mode
To exit the CAT mode, access the ID mode and switch off the main power.
6.1.1.
IIC mode
Select the IIC mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
the remote control.
Subject and item are mentioned on “IIC mode structure”.
To exit the IIC mode, press the R button on the remote control.
To exit the IIC mode, press the R button on the remote control.
12
TH-50PF11EK
6.1.2.
CD mode
Select the CD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
the remote control more than 3 seconds.
Memory data change
To exit the CD mode, press the R button on the remote control.
6.1.3.
SD mode
Select the SD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
the remote control.
To exit the SD mode, press the R button on the remote control.
13
TH-50PF11EK
6.1.4.
MS mode
Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
the remote control more than 3 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of DN-Board.
Destination number
Default setting
6.1.5.
ID mode
Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
the remote control more than 3 seconds.
To exit the ID mode, press the R button on the remote control.
Number
Destination
Number
Destination
0
Japan
16
--
1
North America
17
--
2
Europe
18
China
3
Others
19
China (Hotel)
4
Britain
20
Russia
5
Taiwan
21
Russia (Hotel)
6
Thailand
22
Hong Kong
7
--
23
--
8
Japan (Hotel)
24
--
9
North America (Hotel)
25
--
10
Europe (Hotel)
26
--
11
--
27
--
12
Britain (Hotel)
28
Middle East/Hong Kong
13
--
29
Middle East/Hong Kong (Hotel)
14
Thailand (Hotel)
30
Australia
15
--
31
Australia (Hotel)
Number
Destination
1
North America
Click on the first or last page to see other TH-50PF11EK service manuals if exist.