TH-50PF11EK
4 Specifications
Power Source
220 - 240 V AC, 50/60Hz
Power Consumption
Power on
485 W
Stand-by condition
Save OFF 1.2 W, Save ON 0.7 W
Power off condition
0.4 W
Plasma Display panel
Drive method: AC type 50-inch,
16:9 aspect ratio
Screen size
1,106 mm (W) 
× 622 mm (H) × 1,269 mm (diagonal)
(No. of pixels)
2,073,600 (1,920 (W) 
× 1,080 (H))   [5,760 × 1,080 dots]
Operating condition
Temperature
°C - 40 °C
Humidity
20 % - 80 %
Applicable signals
Colour System
NTSC, PAL, PAL60, SECAM, Modified NTSC
Scanning format
525 (480) / 60i 60p, 625 (575) / 50i 50p, 750 (720) / 60p 50p, 1125 (1080) / 
60i 60p 50i 50p 24p 25p 30p 24sF, 1250 (1080) / 50i
PC signals
VGA, SVGA, XGA, SXGA
UXGA ..... (compressed)
Horizontal scanning frequency 15 - 110 kHz
Vertical scanning frequency 48 - 120 Hz
Connection terminals
DVI-D IN
Video Input
DVI-D 24 Pin x 1
compliance with DVI Revision 1.0
* Refer to page 11 for applicable signals
Audio Input
Stereo mini jack (M3) x 1
0.5 Vrms
Content Protection
Compatible with HDCP 1.1
COMPONENT / RGB IN
Y / G (BNC)
with sync 1.0 Vp-p (75-ohm)
P
B
/B (BNC), P
R
/R (BNC)
0.7 Vp-p (75-ohm)
AUDIO IN (RCA PIN JACK 
× 2)
0.5 Vrms
PC IN
(HIGH-DENSITY Mini-D-SUB 15PIN)
Y or G with sync 1.0 Vp-p (75-ohm)
Y or G without sync 0.7 Vp-p (75-ohm)
B / P
B
 / C
B
: 0.7 Vp-p (75-ohm)
R / P
R
 / C
R
: 0.7 Vp-p (75-ohm)
HD / VD:  1.0 - 5.0 Vp-p (high impedance)
VBS (use HD port)
with picture 1.0 Vp-p (high impedance)
without picture 0.3 Vp-p (high impedance)
AUDIO IN (M3 JACK)
0.5 Vrms
SERIAL
EXTERNAL CONTROL TERMINAL (D-SUB 9PIN) 
RS-232C COMPATIBLE
SPEAKERS
6-ohm, 16 W [8 W + 8 W] (10 % THD)
Accessories Supplied
Remote Control Transmitter
EUR7636090R
Batteries
× R6 Size
Fixing bands
TMME203 
× 1
Dimensions (W 
× H × D)
1,210 mm 
× 724 mm × 95 mm 
Mass (weight)
main unit only
approx. 36.0 kg net
with speakers
approx. 40.0 kg
Note:
• Design and specifications are subject to change without notice. Mass and dimensions shown are approximate.
• This equipment complies with the EMC standards listed below.
EN55022, EN55024, EN61000-3-2, EN61000-3-3.
9
TH-50PF11EK
5 Operating Instructions
10
TH-50PF11EK
GPF11D chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful 
for special function required customers. This should be set at the installation stage.
Note:
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R” button on the remote control and hold for more than 5 seconds.
The “SHIPPING“ menu is displayed and the lock is released when it disappears.
Option Menu for GPF11D series
Option menus
default setting
Contents
Weekly Command Timer
---
Sets Weekly Command Timer.
Onscreen display
On
Enable/Disable to display input mode indication after power on and no signal 
indication.
Initial INPUT
Off
Sets the initial input mode when the power is turned on. Allow input mode selec-
tion while power is on.
Initial VOL level
Off
Sets the initial volume level when the power is turned on. Allow Volume control 
while power is on.
Maximum VOL Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input 
mode by input selection key.
Button lock
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume up/
down)
Remocon User Level
Off
Remote key invalidation.
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Sur-
round, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Off-timer function
Enable
Off-timer operation Enable/Disable.
Initial Power Mode
Normal
Sets the power mode of the unit for when the power recovers from failure or 
after plugging off and in again.
ID select
0
Set ID number from 0 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
Off
Serial ID function On/Off
Display size
Off
Display size function On/Off
Studio W/B
Off
Studio W/B function On/Off
Studio Gain
Off
Studio Gain function On/Off
Slot power
Off
Sets the slot power mode while the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
Power On Screen Delay
Off
You can set the power-on delay time of the displays to reduce the power load, 
when you press 
 to turn on the multiple displays that are set together, for 
example, on MULTI DISPLAY system.
Set each display’s setting individually.
Clock Display
Off
Clock Display function On/Off.
All Aspect
Default
Aspect mode: default/All aspect mode.
Rotate
Off
Rotate function On/Off
Serial Slot Select
Slot1
Selects the slot which communicates serial.
Note: The setting of an external command can be set only from the fixed serial 
terminal.
11
TH-50PF11EK
6 Service Mode
6.1.
CAT (Computer Aided Test) mode
To exit the CAT mode, access the ID mode and switch off the main power.
6.1.1.
IIC mode
Select the IIC mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
Subject and item are mentioned on “IIC mode structure”.
To exit the IIC mode, press the R button on the remote control.
Page of 127