41
TH-50PB2E
9.2.
Adjustment
9.2.1.
RGB white balance adjustment
Instrument Name
Connect to
Setting
• RGB VGA60 W / B pattern
• Color analyzer
(Minolta CA-100 or equivalent)
PC IN terminal
Panel surface
Picture menu: STANDARD
User setting: Normal
except PICTURE: max 30
Steps
Remarks
[Conditions]
• Make sure the front panel to be used on the final set is fitted. 
• Make sure a color signal is not being shown before adjustment.
• Put the color analyzer where there is little color variation.
[Adjustment]
1. Set COMPONENT / RGB-IN SELECT to RGB.
2. Select the IIC mode “PANEL W / B Adj.” item.
3. Check that the color temperature is “COOL (Hi)”.
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at FCh and adjust B drive and R drive so x, y become the "Color temperature 
COOL(Hi)" in the below table. Adjust it again after it lowers of 08h data when the adjust-
ment is NG. ( In addition, adjust it after it lowers by 08h data for NG. )
7. Adjust R/G/B together by multiplication so the maximum drive value in R/G/B becomes 
FCh with the gain ratio kept. (ALL-DRIVE)
8. Set color temperature to “NORMAL (Mid)”.
9. Fix G drive at FCh and adjust B drive and R drive so the highlight window's x, y becomes 
the "Color temperature NORMAL(Mid)" in the below table.
Adjust it again after it lowers of 08h data when the adjustment is NG.
( In addition, adjust it after it lowers by 08h data for NG. )
10. Adjust R/G/B together by multiplication so the maximum drive value in R/G/B becomes 
FCh with the gain ratio kept. (ALL-DRIVE)
11. Set color temperature to “WARM (Low)”.
12. Set G drive to FCh and adjust B drive and R drive so the highlight window's x, y become 
the "Color temperature WARM(Low)" shown in the below table.
Adjust it again after it lowers of 08h data when the adjustment is NG.
(In addition, adjust it after it lowers by 08h data for NG.)
13. Adjust R/G/B together by multiplication so the maximum drive value in R/G/B becomes 
FCh with the gain ratio kept. (ALL-DRIVE)
14. Copy the R drive, G drive and B drive data in NTSC, PAL DVI region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture menu: STANDARD
User setting: Normal
except PICTURE: max 30
Aspect: Full (16 : 9)
Position and size: Normal
• Set OFF to TOUCH-PEN SETTING, and
don't use WHITEBOARD mode.
• “7” key : color temperature select.
• “9” key : Picture menu select.
• Highlight section Signal amplitude 75%
• Drive standard G: FCh
42
TH-50PB2E
43
TH-50PB2E
9.2.2.
YUV white balance adjustment
Instrument Name
Connect to
Setting
• HD(1125/60i) W/B pattern (COMPONENT Output)
• Color analyzer
(Minolta CA-100 or equivalent)
PC IN terminal
Panel surface
Picture menu: STANDARD
User setting: Normal
except PICTURE: max 30
Steps
Remarks
[Conditions]
• Make sure the front panel to be used on the final set is fitted.
• Make sure a color signal is not being shown before adjustment.
• Put the color analyzer where there is little color variation.
[Adjustment]
1. Set COMPONENT / RGB-IN SELECT to COMPONENT.
2. Select the IIC mode “PANEL W / B Adj.” item.
3. Check that the color temperature is “COOL (Hi)”.
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at FCh and adjust B drive and R drive so x, y become the “Color temperature 
COOL (Hi)” in the below table. Adjust it again after it lowers of 08h data when the adjust-
ment is NG. (In addition, adjust it after it lowers by 08h data for NG.)
7. Adjust R/G/B together by multiplication so the maximum drive value in R/G/B becomes 
FCh with the gain ratio kept. (ALL-DRIVE)
8. Set color temperature to “NORMAL (Mid)”.
9. Fix G drive at FCh and adjust B drive and R drive so the highlight window's x, y becomes 
the "Color temperature NORMAL(Mid)" in the below table.
Adjust it again after it lowers of 08h data when the adjustment is NG.
(In addition, adjust it after it lowers by 08h data for NG.)
10. Adjust R/G/B together by multiplication so the maximum drive value in R/G/B becomes 
FCh with the gain ratio kept. (ALL-DRIVE)
11. Set color temperature to “WARM (Low)”.
12. Set G drive to FCh and adjust B drive and R drive so the highlight window's x, y become 
the "Color temperature WARM(Low)" shown in the below table.
Adjust it again after it lowers of 08h data when the adjustment is NG.
(In addition, adjust it after it lowers by 08h data for NG.)
13. Adjust R/G/B together by multiplication so the maximum drive value in R/G/B becomes 
FCh with the gain ratio kept. (ALL-DRIVE)
14. Copy the R drive, G drive and B drive data in YUV1_525ip, YUV3_625ip region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture Menu: STANDARD
User setting: Normal
except PICTURE: max 30
Aspect: Full (16 : 9)
Position and size: Normal
• Set OFF to TOUCH-PEN SETTING, and
don't use WHITEBOARD mode. 
• “7” key : color temperature select.
• “9” key : Picture menu select.
• Highlight section Signal amplitude 75%
• There needs to be Pb/Pr signal by zero sig-
nal. Pb and Pr signals are good in no input-
ting.
• Drive standard G: FCh
44