Panasonic TH-37PR10U / TH-42PR10U Service Manual ▷ View online
11 Adjustment
11.1. RGB white balance adjustment
Instrument Name
Connection
Remarks
·
RGB VGA W/B pattern
·
Color analyzer
(Minolta CA-100 or equivalent)
PC input
Panel surface
Panel surface
User setting: Normal
(Picture menu: Standard)
(Picture menu: Standard)
Procedure
Remarks
·
Ensure aging is adequate.
·
Make sure the front panel to be used on the final set is fitted.
·
Make sure a color signal is not being shown before adjustment.
·
Put the color analyzer where there is little color variation.
1.
Set COMPONET/RGB-IN SELECT to RGB.
2.
Select the IIC mode “PANEL W/B Adj.” item.
3.
Check that the color temperature is “COOL (High)”.
4.
Output a white balance pattern.
5.
Touch the signal receiver of color analyzer to the highlight window’s center.
6.
Fix G drive at E0h and adjust B drive and R drive so x, y become the “Color temperature
High” in the below table.
High” in the below table.
7.
Increase R/G/B together so the maximum drive value in R/G/B becomes FCh.
8.
Set color temperature to “NORMAL (Medium)”.
9.
Fix G drive at E0h and adjust B drive and R drive so the highlight window’s x, y becomes
the “Color temperature Medium” in the below table.
the “Color temperature Medium” in the below table.
10. Increase R/G/B together so the maximum drive value in R/G/B becomes FCh.
11. Set color temperature to “WARM(Low)”.
12. Set G drive to E0h and adjust B drive and R drive so the highlight window’s x, y become
the “Color temperature Low” shown in the below table.
13. Increase R/G/B together so the maximum drive value in R/G/B becomes FCh.
14. Copy the R drive, G drive and B drive data in NTSC, PAL DVI region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture Menu: Standard
Picture: 25
Aspect: Full
Position and size: Normal
Picture: 25
Aspect: Full
Position and size: Normal
·
Highlight section Signal amplitude 75%
·
Cutoff standard G: 80h
·
Drive standard G: E0h
41
TH-37PR10U / TH-42PR10U
42
TH-37PR10U / TH-42PR10U
11.2. HD white balance adjustment
Instrument Name
Connection
Remarks
·
HD W/B pattern (COMPONENT Output)
·
Color analyzer
(Minolta CA-100 or equivalent)
PC input
Panel surface
Panel surface
User setting: Normal
(Picture menu: Standard)
(Picture menu: Standard)
Procedure
Remarks
·
Ensure aging is adequate.
·
Make sure the front panel to be used on the final set is fitted.
·
Make sure a color signal is not being shown before adjustment.
·
Put the color analyzer where there is little color variation.
1.
Set COMPONENT/RGB-IN SELECT to COMPONENT
2.
Select the IIC mode "PANEL W/B Adj.” item.
3.
Check that the color temperature is “COOL (High)”.
4.
Output a white balance pattern.
5.
Touch the signal receiver of color analyzer to the highlight window’s center.
6.
Fix G drive at E0h and adjust B drive and R drive so x, y become the "Color temperature
High" in the below table.
High" in the below table.
7.
Increase R/G/B together so the maximum drive value in R/G/B becomes FCh.
8.
Set color temperature to “NORMAL (Medium)”.
9.
Fix G drive at E0h and adjust B drive and R drive so the highlight window´s x, y becomes
the "Color temperature Medium" in the below table.
the "Color temperature Medium" in the below table.
10. Increase R/G/B together so the maximum drive value in R/G/B becomes FCh.
11. Set color temperature to "WARM (Low)".
12. Set G drive to E0h and adjust B drive and R drive so the highlight window´s x, y become
the “Color temperature Low” shown in the below table.
13. Increase R/G/B together so the maximum drive value in R/G/B becomes FCh.
14. Copy the R drive, G drive and B drive data in YUV1_525ip, YUV3_625ip region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture Menu: Standard
Picture: 25
Aspect: Full
Position and size: Normal
Picture: 25
Aspect: Full
Position and size: Normal
·
Highlight section Signal amplitude 75%
·
Cutoff standard G: 80h
·
Drive standard G: E0h
43
TH-37PR10U / TH-42PR10U
44
TH-37PR10U / TH-42PR10U
Click on the first or last page to see other TH-37PR10U / TH-42PR10U service manuals if exist.