DOWNLOAD Panasonic TH-152UX1 / TH-152UX1W / TH-152UX1C Service Manual ↓ Size: 9.8 MB | Pages: 127 in PDF or view online for FREE

Model
TH-152UX1 TH-152UX1W TH-152UX1C
Pages
127
Size
9.8 MB
Type
PDF
Document
Service Manual
Brand
Device
Plasma / GPF13UX CHASSIS
File
th-152ux1-th-152ux1w-th-152ux1c.pdf
Date

Panasonic TH-152UX1 / TH-152UX1W / TH-152UX1C Service Manual ▷ View online

4
TH-152UX1 / TH-152UX1W / TH-152UX1C
2 Warning
2.1.
Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensi-
tive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Elec-
trostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor [chip] components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as alumi-
num foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as [anti-static (ESD protected)] can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals.   These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or compara-
ble conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise ham less motion such as the brush-
ing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient
to damage an ES device).
5
TH-152UX1 / TH-152UX1W / TH-152UX1C
2.2.
About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues. For service and repair work, we’d
suggest the use of Pb free solder as well, although Pb solder may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol PbF stamped on the back of PCB.
Caution
• Pb free solder has a higher melting point than standard solder. Typically the melting point is 50 ~ 70 
°F (30~40 °C) higher. Please
use a high temperature soldering iron and set it to 700 ± 20 
°F (370 ± 10 °C).
• Pb free solder will tend to splash when heated too high (about 1100 
°F or 600 °C).
If you must use Pb solder, please completely remove all of the Pb free solder on the pins or solder area before applying Pb sol-
der. If this is not practical, be sure to heat the Pb free solder until it melts, before applying Pb solder.
• After applying PbF solder to double layered boards, please check the component side for excess solder which may flow onto the
opposite side. (see figure below)
Suggested Pb free solder
There are several kinds of Pb free solder available for purchase. This product uses Sn+Ag+Cu (tin, silver, copper) solder. How-
ever, Sn+Cu (tin, copper), Sn+Zn+Bi (tin, zinc, bismuth) solder can also be used.
6
TH-152UX1 / TH-152UX1W / TH-152UX1C
3 Service Navigation
3.1.
NANODRIFT
Customers could select the NANODRIFT SAVER which
reduces image retention OFF in the previous systems, but this
system customers can not select OFF.
If customers simply wants to select OFF, customers can set to
OFF according to the following steps.
However, the image retention cannot be guaranteed in this
case.  
Setup steps to select NANODRIFT SAVER to OFF
1. Press SETUP
2. Select Extended life settings
3. Select Custom Settings
4. Set the cursor to NANODRIFT SAVER and press OK
more than 5 sec
5. YES/NO Screen of OFF selection is displayed.
6. Select YES, then becomes possible to select OFF.
3.2.
VR Adjustment at SCD board
*How to adjust VR by stopping the fan not to operate SOS
When adjustment VR is under the fan, please stop the fan by
following steps and turn adjustment VR. 
*If you disconnect the connectors of the Fan, SOS works,
and the power supply is turn off so you can not adjust it.
Steps to stop the Fan
1. Access the CAT mode and select CD mode.(See 
chap.6.1.) 
2. Change the data of MONITOR-EEPROM Change.
Addr :change [00 01] to [00 A7] by Up/Down buttons
Data :change[**  **] to [** 00] by [8],[0] buttons
3. Select ID Mode (See chap.6.1.5.) and after ID Mode dis-
played, turn off the SW of the unit and then turn on again.
4. The unit will start with the Fan stopped, and then adjust
VR.
 Note:
After VR adjustment is finnished, change MONITOR-
EEPROM Change to the former value.(See step 2)
Addr :change [00 01] to [00 A7] by Up/Down buttons
Data :change [00 00] to [00 01] by [8],[0] buttons
Select ID Mode (See chap.6.1.5.) and after ID Mode dis-
played, turn off the SW of the unit and then turn on again.
 Check that the unit will start and the Fan works.
3.3.
SCU/SCD boards replacement
SCU and SCD boards should be replaced at the same time.
3.4.
SSU/SSD boards replacement
SSU and SSD boards should be replaced at the same time.
3.5.
Simple signal flow
3.5.1.
Power Supply flow
3.5.2.
Discharge signal flow
3.5.3.
LVDS signal and Control Command
signal flow for D board
7
TH-152UX1 / TH-152UX1W / TH-152UX1C
3.6.
Option Menu
Page of 127
Display

Panasonic TH-152UX1 / TH-152UX1W / TH-152UX1C Service Manual ▷ Download

  • DOWNLOAD Panasonic TH-152UX1 / TH-152UX1W / TH-152UX1C Service Manual ↓ Size: 9.8 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic TH-152UX1 / TH-152UX1W / TH-152UX1C in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic TH-152UX1 / TH-152UX1W / TH-152UX1C Plasma. Information contained in Panasonic TH-152UX1 / TH-152UX1W / TH-152UX1C Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.