2 FOR SERVICE TECHNICIANS
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
 1. Cover the plastic parts boxes with aluminum foil.
 2. Ground the soldering irons.
 3. Use a conductive mat on the worktable.
 4. Do not touch IC or LSI pins with bare fingers.
7
KX-TES824UA / KX-TEM824UA /
3 CAUTION
3.1. SAFETY PRECAUTIONS
 1. Before servicing, unplug the power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components for safety.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
3.2. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with ohmmeter between the jumpers AC plug and each exposed metal cabinet part, such as
screw threads, control shafts, handle brackets, etc.
Note:
Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired and
rechecked before it is returned to the customer.
3.3. BATTERY CAUTION
 1. Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s Instructions.
 2. The lithium battery is a critical component (type No.CR23541). Please observe for the proper polarity and the exact location
when replacing it and soldering the replacement lithium battery in.
3.4. CAUTION
The power socket wall outlet should be located near this equipment and be easily accessible.
8
KX-TES824UA / KX-TEM824UA /
4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus
Original bus (16-bit, 24 MHz)
Switching
Space Division CMOS Crosspoint Switch
Power Input
100 V AC to 240 V AC, 1.5A to 0.75A, 50 Hz/60Hz
External Battery
+24 V DC (+12 V DC x 2)
Maximum Power Failure Tolerance
300 ms (without using backup batteries)
Memory Backup Duration
7 years
Dialling
Outside (CO) Line
Pulse (10 pps, 20 pps) or Tone (DTMF)
Extension
Pulse (10 pps, 20 pps) or Tone (DTMF)
Intercom Path
4
Mode Conversion
Pulse-DTMF
Ring Frequency
20 Hz/25 Hz (selectable)
Operating Environment
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
Conference Call Outside (CO) Line
2
Music on Hold (MOH)
1 port
Selectable MOH: Internal/External/Tone
Paging
Internal
1
Extension
1 port
Serial Interface Port
RS-232C
1
USB 1.1
1
Extension Connection Cable SLT
1 pair wire (T, R)
PT
2-pair wire (T, R, H, L)
DSS Console
1-pair wire (H, L)
Dimension
368 mm (W) x 284 mm (H) x 102 mm (D)
Weight (when fully expanded)
Approx. 3.5 kg
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
PT
40
SLT
600
Ω including set
Doorphone
20
Minimum Leakage Resistance
15000
Ω minimum
Maximum Number of Extension
Instruments per Line
1 PT or SLT in standard connection
1 PT and 1 SLT in parallel connection
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the ringing load
Outside (CO) Line Loop Limit
1600
Ω maximum
Hookswitch Flash/Recall Timing Range
24 ms-2032 ms
Door Opener Current Limit
30 V DC/125 V AC, 3 A maximum
Paging Terminal Impedance
600
MOH Terminal Impedance
10000
4.3. SYSTEM CAPACITY
4.3.1. System Capacity
KX-TES824
KX-TEM824
Basic System
Outside (CO) lines
3
6
Extensions
8
16
Fully Expanded System
Outside (CO) lines
8
8
Extensions
24
24
9
KX-TES824UA / KX-TEM824UA /
4.3.2. Maximum Cards Terminal Equipment
ltem
KX-TES824
KX-TEM824
Extension Terminal
48
48
3-Port Analogue CO Line and 8-Port Hybrid Extension Card
1
-
2-Port Analogue CO Line and 8-Port Single Line Telephone Extension Card
1
1
8-Port Single Line Telephone Extension Card
1
1
Message Expansion Card for DISA/UCD OGMs
1
1
4-Port Doorphone Card
1
1
3-Port Caller ID Card
3
3
2-Channel Voice Message Card
1
1
Doorphone
4
4
Door Opener
4
4
Pager
1
1
Music on Hold (MOH)
1
1
DSS Console
2
2
4.3.3. System Data
ltem
Max. Quantity
Operator
1
System Speed Dialling
100
One-touch Dialling
24 per extension (PT)
Personal Speed Dialling
10 per extension
Call Park Area
10
Absent Message
6
Toll Restriction (TRS) COS
5
Extension Group
8
Message Waiting
8 per extension
Message for Built-in Voice Message
128 messages (total 60 minutes)
5 SYSTEM OVERVIEW
5.1. SYSTEM COMPONENTS
Model
Description
Main Unit
KX-TES824UA
KX-TEM824UA
Advances Hybrid System: 3 to 8 Outside (CO) Lines, 8 to 24 Extensions
Advances Hybrid System: 6 to 8 Outside (CO) Lines, 16 to 24 Extensions
Optional Service Cards KX-TE82461X
KX-TE82474X
KX-TE82480X
KX-TE82483X
KX-TE82491X
KX-TE82492X
KX-TE82493X
4-Port Doorphone Card
8-Port Single Line Telephone Extension Card
2-Port Analogue CO Line and 8-Port Single Line Telephone Extension Card
3-Port Analogue CO Line and 8-Port Hybrid Extension Card
Message Expansion Card for DISA/UCD OGMs
2-Channel Voice Message Card
3-Port Caller ID Card
Proprietary Equipment
KX-T30865
KX-A227X
Doorphone
Backup Battery Cable
10
KX-TES824UA / KX-TEM824UA /
Page of 127
Display

Click on the first or last page to see other KX-TES824UA / KX-TEM824UA / KX-TE82461X / KX-TE82474X / KX-TE82480X / KX-TE82483X / KX-TE82491X / KX-TE82492X / KX-TE82493X / KX-A227X / KX-TES824UAPP / KX-TEM824UAPP service manuals if exist.