Panasonic KX-TCA355RU Service Manual ▷ View online
33
KX-TCA355RU
11.1.3.3. Step [3] Select Download file
[3]-(1) Download Program Main Menu
Push "Reference" to select the download file. (Download Filename tca355vXXX.hex) XXX=Version
34
KX-TCA355RU
11.1.3.4. Step [4] Download Start
[4]-(1) Click "download" key
[4]-(2) Turn the power of target (TCA355) to [OFF]
(Keep pressing "POWER" key for while 2 seconds)
[4]-(3) Keep pressing "POWER" key until step [4]-(6)
This operation will not turn the power of target to on.
If target power turns on, check following item. Then try again from step [1]-(1).
(A) Check serial PC cable connection "PC" with "TCA355".
(B) Check Configuration. (Refer to Step [1]-(2))
(C) Check PC cable attachment of target.
If target power turns on, check following item. Then try again from step [1]-(1).
(A) Check serial PC cable connection "PC" with "TCA355".
(B) Check Configuration. (Refer to Step [1]-(2))
(C) Check PC cable attachment of target.
[4]-(4) Click "Download"
Communicating PC with Target.
Don't release the "POWER" key in this step. If release the "OFF" key, downloading will be failed.
Don't release the "POWER" key in this step. If release the "OFF" key, downloading will be failed.
35
KX-TCA355RU
[4]-(5) Communication check "OK"
If communication check become "OK", Display will show "CRC OK".
If communication NG, click "cancel" key, then back to step [4]-(1) and try download again.
If communication NG, click "cancel" key, then back to step [4]-(1) and try download again.
[4]-(6) Downloading Start
After several seconds, Display shows "Flash Program Start".
You can release the "POWER" key in this step.
You can release the "POWER" key in this step.
36
KX-TCA355RU
[4]-(7) Downloading Complete
If downloading finished, display shows "Download finished successfully!".
Click "off" then disconnect the serial PC cable.
Click "off" then disconnect the serial PC cable.
11.2. Adjustments (Handset and Charger Unit)
11.2.1. Adjustment (Handset)
Items
Adjustment
Point
Procedure*
Check or
Replace Parts
(A)* 1.8V Supply Confirma-
tion
CK5
1. Confirm that the voltage between test point "CK5" and GND is 1.85V±0.02V.
2. Adjust the 1.8V voltage of CK5 executing command "bandgap XX" (XX is the
2. Adjust the 1.8V voltage of CK5 executing command "bandgap XX" (XX is the
value).
IC201,
Q104,
R110
Q104,
R110
(B) 2.7V Supply Confirma-
tion
-
1. Confirm that the voltage between "CK6" and GND is 2.775V±0.15V.
IC201,
Q105,R111,
R112,R113
Q105,R111,
R112,R113
(C)* BBIC Confirmation
-
1. BBIC Confirmation (Execute the command "getchk").
2. Confirm the returned checksum value.
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC201,
X100,C203
X100,C203
(D) Charge Control Check &
Charge Current Monitor
Confirmation
Confirmation
-
1. Apply 6V between JT101(+) and JT102(-) with current limit of PSU to
200mA.
2. Confirm that the charge current is ON/OFF.
3. SW to decrease current limit of PSU to 100mA.
4. Confirm that the charge current is stable.
3. SW to decrease current limit of PSU to 100mA.
4. Confirm that the charge current is stable.
IC201,
Q101,L101,
L102,Q102,
R101,R103,
Q103,R117,
D101,D102,
D103
Q101,L101,
L102,Q102,
R101,R103,
Q103,R117,
D101,D102,
D103
(E)* Charge Detection (OFF)
Confirmation
-
1. Stop supplying 6V to JT101(+) and JT102(-).
2. Execute the command "charge".
3. Confirm that the returned value is 0x01 (hex).
2. Execute the command "charge".
3. Confirm that the returned value is 0x01 (hex).
IC201,
R118,C111,
L101,L102,
R118,C111,
L101,L102,
(F)* Battery Monitor Confir-
mation
-
1. Apply 3.8V ± 0.005V between BATT(+) and BATT(-).
2. Execute the command "Backloff", then "readbatt".
3. Confirm:
2. Execute the command "Backloff", then "readbatt".
3. Confirm:
29 returned value 36 (Hex)
4. Adjust the Battery Monitor executing command "wreeprom 00 01 01 XX",
then "wreeprom 00 36 01 XX-0E" (XX is the value).
IC201,
R216,R217,
C230
R216,R217,
C230
(G) Battery low Confirmation
-
1. Apply 3.5V between BATT(+) and BATT(-).
2. Confirm that there is no flashing of Battery Icon.
3. Apply 3.3V between BATT(+) and BATT(-).
4. Confirm that there is flashing of Battery.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 3.3V between BATT(+) and BATT(-).
4. Confirm that there is flashing of Battery.
IC201,
R216,R217,
C230
R216,R217,
C230
(H)* BBIC Clock Adjusment
SYRI
1. Execute the command "conttx".
2. Adjust the frequency of SYRI executing the command "setfreq xx (where xx
2. Adjust the frequency of SYRI executing the command "setfreq xx (where xx
is the value)" so that the reading of the frequency counter is 10.368000MHz
±10Hz.
±10Hz.
IC201,
X100,C203,
C232,L201,
C231,C610
X100,C203,
C232,L201,
C231,C610
Click on the first or last page to see other KX-TCA355RU service manuals if exist.