DOWNLOAD Panasonic KV-S5076H / KV-S5046H Service Manual ↓ Size: 36.94 MB | Pages: 127 in PDF or view online for FREE

Model
KV-S5076H KV-S5046H
Pages
127
Size
36.94 MB
Type
PDF
Document
Service Manual
Brand
Device
Service Manual / Other / HIGH SPEED COLOR SCANNER
File
kv-s5076h-kv-s5046h.pdf
Date

Panasonic KV-S5076H / KV-S5046H Service Manual ▷ View online

4
1 GENERAL PRECAUTIONS
1.1.
Safety Precautions
1. Before servicing, unplug the power cord to prevent electrical shock hazard.
2. When replacing parts, use only manufacture’s recommended components for safety.
3. Check the condition of power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the wire dressing, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, perform the following electrical tests to prevent shock hazard.
6. The power supply unit in this scanner contains dangerous levels energy.
1.2.
Electrical Tests
1. Unplug the power cord and check for continuity between the earth ground connection on the plug and the metal cabinet.
There should be zero ohm resistance found.
2. With the unit unplugged, short the AC Live-Neutral of the plug with a jumper wire. 
3. Turn ON the power switch.
4. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part, such
as screwheads, etc.
Note
   Some exposed parts may be isolated from the chassis by design. They read infinity.
5. If the measurement is less than 1 M
, there may be a danger of electric shock.
Note
   This hazardous condition must be corrected before the unit is returned to the end user. 
1.3.
Standard for Repair Service
Repair service shall be provided in accordance with repair technology information such as service manual
so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
1. When performing repairs, neither the products nor its parts or components shall be modified.
2. If cable assembly is supplied as the smallest unit when servicing, make sure to replace
the cable assembly.
5
1.4.
For Service Technicians
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help to prevent recurring malfunctions.
1. Cover plastic parts with aluminum foil.
2. Ground soldering irons.
3. Use a conductive mat on the worktable.
4. Do not hold IC or LSI pins with bare fingers.
1.5.
About Lead Free Solder (PbF: Pb free)
Note
• In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder
that contains lead.
• We will use PbF when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn),
Silver (Ag), and Copper (Cu).
• This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and
repair work we suggest using the same type of solder.
Distinction of PbF PCB
• PCBs manufactured using lead free solder will have a PbF stamp on the PCB.
Caution
• PbF solder has a melting point that is 50 
 - 70 F, (30  - 40 C) higher than Pb solder. 
Use a soldering iron with temperature control and adjust it to 700 
 ± 20 F (370  ± 10 C).
• Exercise care when using higher temperature soldering irons: Do not heat the PCB for too long time in order to
prevent solder splash or damage to the PCB.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100 
F (600 C). 
• When applying PbF solder to double layered boards, check the component side for excess solder which may flow onto
the opposite side (See figure below).
1.5.1.
Suggested Pb free solder
We recommend you to use the following solder when re-soldering components for repair. Before using other Pb free solder than the
following solder, make sure to confirm that the solder maker (you use) has the license agreement for Pb free solder.
Supplier: Senju Metal Industry Co., Ltd. (http://www.senju-m.co.jp)
Part Description in Senju: EcoSolder RMA02 P3 M705 Series
1.6.
About RoHS
This product is fully compliant with the national laws transposed from the EU Directive on the restriction of the use of certain
hazardous substances (RoHS) in electrical and electronic equipment, effective 1st July 2006 in the EU countries.
In order for the product to comply with the RoHS Directive, the six particular substances (lead, mercury, cadmium, hexavalent
chromium, polybrominated biphenyls, and polybrominated diphenyl ethers) have been either totally eliminated or limited to the
concentration level below maximum allowed. Consequently spare parts have been changed to RoHS-compliant parts where
applicable.
Due to the application of RoHS legislation to spare parts, non-compliant spare parts cannot be used to repair compliant products put
on the EU market on or after 1st July 2006. Therefore make sure to order and use RoHS-compliant spare parts listed in this
manual.
6
2 SPECIFICATIONS
Item
Model No.
*
1
KV-S5076H Series
*
1
KV-S5046H Series 
Scanner
Scanning Face
Duplex
Scanning Method
Color CIS (600 dpi)
Scanning Width
307 mm (12.09 in.)
Readout
Speed 
*2
 
Black & 
White, Color 
(JPEG)
200/300dpi 
A4 Landscape
100 ppm / 200 ipm
80 ppm / 160 ipm
Resolution
100 . 600 dpi (1 dpi step)
Optical: 300 dpi / 600 dpi (Main and Sub feeding directions)
Image Output
Binary, Grayscale, Color, MultiStream (Binary and Color, Binary and Grayscale)
Tonal Gradation
Dither (64 step gradation), Error diffusion (64 step gradation), Grayscale (8 bit), Color (24 bit)
Image Control
Image emphasis, Dynamic threshold, Automatic separation, Invert, White level from paper
Other Functions
Patch code detection (Kodak patch 2,3,T), Double feed detection
Paper
Size
When feeding multiple sheets:
Landscape orientation: 48 to 307 mm (1.9 to 12.09 in.), 
portrait orientation: 70 to 432 mm (2.8 to 17 in.)
When feeding one sheet:
Landscape orientation: 48 to 307 mm (1.9 to12.09 in.), 
portrait orientation: 70 mm (2.8 in.) to unlimited
Thickness
0.04 to 0.2 mm (1.6 to 7.9 mils)   
Note: 1 mil = 1 / 1000 in.
Weight
20 to 157 g/m
2
 (5 to 42 lb.)
Note: 1 lb. = 3.75 g/m
2
Detection
Skew detection
Interface 
USB 2.0 / USB 3.0
Hopper Capacity
300 sheets [75 g/m
2
 (20 lb.)80 g/m
2
] / 350 sheets [64 g/m
2
Memory Size
512 MB
256 MB
Unit
External Dimensions
 (Width x Depth x Height)
468 x 444 x 344 mm (18.5 x 17.5 x 13.5 in.)
Weight
17 kg (37.3 lb.)
Power Requirement
AC 100 V to AC127 V, 50 / 60 Hz, 1.5 A
AC 220 V to AC240 V, 50 / 60 Hz, 0.8 A
Power
consumption
Maximum 
(Scanning)
1.5 A (AC 100 V to 127 V)
0.8 A (AC 220 V to 240 V)
Minimum 
(Ready)
30 W or less (AC 100 V to 127 V)
30 W or less (AC 220 V to 240 V)
Sleep Mode
1.2 W or less (AC 100 V to 127 V)
1.2 W or less (AC 220 V to 240 V)
Off Mode
0.5 W or less (AC 100 V to 127 V)
0.5 W or less (AC 220 V to 240 V)
Environment Operating Temperature and
Humidity
Temperature: 10 
C to 35 C (50 F to 95 F)
Humidity: 20 % to 80 %RH
Storage Temperature and
Humidity
Temperature: 0 
C to 40 C (32 F to 104 F)
Humidity: 10 % to 80 %RH
Accessories
Power cord, USB cable, Double-feed Prevention Roller, Cleaning Paper, Shading Sheet, Quick 
Installation Guide, CD-ROM (Operation Manual, Device driver, ISIS, TWAIN, ICP, User Utility, 
Control Sheet, Warranty Information), Printed materials (EAC Leaflet)
PbF (Pb Free)
Applied to PCB assemblies CONTROL, DRIVE, POWER, USS RELAY, USR RELAY, USR SEN-
SOR, SLIP DETECT SENSOR, STARTING SENSOR, USS/WAITING SENSOR, PANEL, DFP 
HOME SENSOR, ENDING SENSOR, PAPER FEED SELECT SENSOR, BENT RELAY, BENT 
PAPER SENSOR R(L), BENT PAPER SENSOR R(R), BENT PAPER SENSOR S(L), and BENT 
PAPER SENSOR S(R) BOARDS, REFERENCE PLATE (F) HOME SENSOR, REFERENCE PLATE 
(B) HOME SENSOR, HOPPER POSITION SENSOR, SKEW SENSOR(R), SKEW SENSOR(L)
Note: Distinction of PbF PCB
PCBs manufactured using lead free solder will have a PbF stamp on the PCB.
Option
*3
 Roller Cleaning Paper (KV-SS03)
*3
 Imprinter Unit (KV-SS014)
*3 
Ink Cartridge (KV-SS021)
*4 
Roller Exchange Kit (KV-SS060)
*5 
Flatbed Scanner (KV-SS081)
7
     Note:
         
*1
: KV-S5076H/S5046H Series
          
      
*2
: The scanning speed depends on the test environment. In addition, it differs depending on the host computer operating
            environment or applications.
      
      
*3
: KV-SSxxx (All Area except for China)
            KV-SSxxx-CN (Only for China)
              (xxx: 03, 014, or 021)
 
      
*4
: KV-SS060-M (For North America)
            KV-SS060-U (For Europe, Russia, Korea and Brazil)
            KV-SS060-CN (For China)
            KV-SS060-SX (For India)
      
*5
: KV-SS081-U (For Europe and Russia)
            KV-SS081-CN (For China)
            KV-SS081-B (For Brazil)
Model
Area
Serial No.
Power Cord
KV-S5076H-M
North America
G29 xxxx 1001
For 100 to 120 V
KV-S5076H-J
North America (made in Japan)
G36 xxxx 1001
For 100 to 120 V
KV-S5076H-U
Europe, Russia
G30 xxxx 1001
For 220 to 240 V
KV-S5076H-K
Korea
G32 xxxx 1001
For 220 to 240 V
KV-S5076H-CN
China
G33 xxxx 1001
For 220 to 240 V
KV-S5076H-B
Brazil
G31 xxxx 1001
127 V
KV-S5076H-SX
India
G34 xxxx 1001
For 220 to 240 V
KV-S5046H-M
North America
G37 xxxx 1001
For 100 to 120 V
KV-S5046H-J
North America (made in Japan)
G44 xxxx 1001
For 100 to 120 V
KV-S5046H-U
Europe, Russia
G38 xxxx 1001
For 220 to 240 V
KV-S5046H-K
Korea
G40 xxxx 1001
For 220 to 240 V
KV-S5046H-CN
China
G41 xxxx 1001
For 220 to 240 V
KV-S5046H-B
Brazil
G39 xxxx 1001
127V
KV-S5046H-SX
India
G42 xxxx 1001
For 220 to 240 V
Page of 127
Display

Panasonic KV-S5076H / KV-S5046H Service Manual ▷ Download

  • DOWNLOAD Panasonic KV-S5076H / KV-S5046H Service Manual ↓ Size: 36.94 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic KV-S5076H / KV-S5046H in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic KV-S5076H / KV-S5046H Service Manual / Other. Information contained in Panasonic KV-S5076H / KV-S5046H Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.