2. Door Switch (Micro switch) does
    not work correctly.
1. Execute Key/Sensor in Sec. 9.3.6 to check 
    the door switch (Door Sensor) ON/OFF 
    condition.
2. Check the condition between the Door
    Switch and CN4002 on DRIVE Board.
3. Check the Door Switch mechanical 
    condition.
4. Replace a faulty cable.
5. Replace the Door Switch.
3. Monitor circuit to check the door
    ON/OFF condition is broken.
1. Execute Key/Sensor in Sec. 9.3.6 to check
    the door switch ON/OFF condition.
2. Check 24VIL signal line (CN4002-2nd pin)
3. Check DOOR signal (CN4003-3rd)
      
 +5 V (when the door is open)
             0 V (when the door is closed)
4. Replace a faulty cable.
5. Replace the DRIVE Board.
6. Replace the CONTROL Board.
F17 (SD-RAM error)
87
xx
00
00 Access error to SDRAM (IC0040 to 
IC0043, IC0055 to IC0058) on the 
CONTROL Board
1. Check the soldering condition of the parts
    surrounding the ASIC (IC0035 and IC0038)
2. Check the soldering condition of the SDRAM
    (IC0040 to IC0043, IC0055 to IC0058). 
3. Replace faulty parts or CONTROL Board.
F31 (Analog IC error)
95
xx
00
00 Access error to Analogue IC
1. Check the following connection and 
    soldering condition to repair it.
   a. CIS(F) Unit to CN2022(CIS(F) RERAY
         Board)
b. CN2024(CIS(F) RERAY Board) to
         CN1004(CONTROL Board).
c. CIS(B) Unit to CN2025(CIS(B) RERAY
          Board).
d. CN2027(CIS(B) RERAY Board) to
         CN1006(CONTROL Board).
e. IC0006(CONTROL Board) and its 
         surround circuit.
2. Check the following signals during 
    power-on.
    a. CN1004:CIS_SENB_F, CIS_SDO_F,
        CIS_SCLK, CIS_SDI,+3.9V
    b. CN1006:CIS_SENB_B, CIS_SDO_B,
        CIS_SCLK, CIS_SDI, +3.9V
         For Example:CIS_SDO_F:See Fig.10
3. Replace faulty parts or boards.
F33 (USB IC error)
97
00
00
00 Access error to USB Controller
1. Check the soldering condition of the USB 
    Controller (IC0001) and its surrounding
    circuit on the CONTROL Board to repair it.
2. Check the soldering condition of CPU 
    (IC0006) on the CONTROL Board.
3. Replace faulty parts or CONTROL Board.
F34 (EEPROM error)
98
00
00
00 Access error to EEPROM
1. Check the soldering condition of the     
    EEPROM (IC0004) and its surrounding 
    circuit on the CONTROL Board.
2. Check the soldering condition of the CPU 
    (IC0006-80,45, and 110th pins) and their 
    surrounding circuit on the CONTROL Board.
3. Replace faulty parts or CONTROL Board.
F35 (Image process-
ing FPGA/DDR2 error)
99
xx
00
00 Access error to DDR2(IC0033 or 
IC0034)
1. Check the soldering condition of the parts 
    surrounding FPGA (IC0030 and IC0031).
2. Check the soldering condition of the DDR2 
    (IC0033 and IC0034).
3. Replace faulty parts or CONTROL Board.
F36 (Front ASIC error)
9A
xx
00
00 Access error to SDRAM (IC0040 
and IC0041 and IC0055,IC0056) 
 
1. Check the soldering condition of the parts 
    surrounding the ASIC (IC0035).
2. Check the soldering condition of the SDRAM 
    (IC0040 and IC0041 and IC0055, IC0056).
3. Replace faulty parts or CONTROL Board.
Error Code
Possible Cause
Check Point
Remarks
Classified Code  ST1 ST2 ST3 ST4
128
F38 (Back Gate Array 
error)
9C
xx
00
00 Access error to SDRAM (IC0042 
and IC0043 and IC0057, IC0058)
1. Check the soldering condition of the parts 
    surrounding the Gate Array (IC0038).
2. Check the soldering condition of the 
    SDRAM(IC0042 to IC0043 and IC0057, 
     IC0058).
3. Replace faulty parts or CONTROL Board.
F40 (Hopper error)
00
00
00
00 Hopper does not work
Check the condition of both hopper gear and
rack. 
Check the condition of hopper drive gear train.
1. Check the following connection and 
    soldering condition on each connector.
a. CN3002(DFP HOME SENSOR Board) to
         CN2003(USR RERAY Board).
b. CN2001(USR RELAY Board) to CN1007
         (CONTROL Board).
c. CN3024(HOPPER POSITION SENSOR
         Board) to CN2035(BENT RELAY Board).
d. CN2030(BENT RELAY Board) to CN2007
         (USS RELAY Board).
e. CN2006(USS RELAY Board) to CN1008
         (CONTROL Board).
2. Check the soldering condition of IC3004 one
     the DFP HOME SENSOR Board.
3. Check the soldering condition of IC0053 and
     IC0011 and CPU(IC0006) and their 
     surrounding circuit on the CONTROL Board.
4. Check the soldering condition of IC3005 one
     the HOPPER POSITION SENSOR Board.
5. Replace faulty parts or related Board.
F42 (DFP Home 
Position error) 
32
00
00
00 1. DFP Pressure Motor does not 
work, properly.
Refer to the 7th item on Classified Code U12.
F43 (Platen(front) 
motor error) 
00
00
00
00 3. Platen(front) motor does not 
work properly.
Check the condition of both gear train. 
1. Check the following connection and 
    soldering condition on each connector.
a. Platen F Motor to CN4011.
b. CN4006(DRIVE Board) to CN1011
         (CONTROL Board).
c. CN3021(PLATEN SENSOR(F) Board) to
         CN2020(USR RELAY Board).
d. CN2001(USR RELAY Board) to CN1007
         (CONTROL Board).
2. Check the soldering condition of IC4021 and
    their surrounding circuit on the DRIVE
     Board.
3. Check the soldering condition of IC3008 and
    their surrounding circuit on the PLATEN
     SENSOR(F) Board.
4. Check the soldering condition of IC0053,
     IC0015, IC0011 and CPU(IC0006) and their
    surrounding circuit on the CONTROL Board.
5. Replace faulty parts or related Board.
F44 (Plate(Back) motor
 error) 
00
00
00
00 3. Platen(back) motor does not 
work properly.
Check the condition of both gear train. 
1. Check the following connection and 
    soldering condition on each connector.
a. Platen B Motor to CN4012.
b. CN4006(DRIVE Board) to CN1011
         (CONTROL Board).
c. CN3022(PLATEN SENSOR(B) Board) to
         CN2018(USS RELAY Board).
d. CN2006(USS RELAY Board) to CN1008
         (CONTROL Board).
2. Check the soldering condition of IC4022 and
    their surrounding circuit on the DRIVE Board.
3. Check the soldering condition of IC3009 and
    their surrounding circuit on the PLATEN
    SENSOR(B) Board.
4. Check the soldering condition of IC0053,
    IC0015, IC0011 and CPU(IC0006) and their
    surrounding circuit on the CONTROL Board.
5. Replace faulty parts or related Board.
Error Code
Possible Cause
Check Point
Remarks
Classified Code  ST1 ST2 ST3 ST4
129
2. DFP Pressure Motor control
circuit does not work, properly.
Refer to the 8th item on Classified Code U12.
3. Rotation from DFP Pressure 
Motor is not normally transferred to 
the DFP Adjustable Drive Shaft 
that controls DFP Roller's position. 
1. Check the ADF mechanism. (See Sec.6.)
2. Execute DFP Pressure Drive in Sec. 9.3.6 
    to check the ADF mechanism. 
4. DFP Home Detector does not 
work, correctly. 
1. Execute Key/Sensor test in the Sec. 9.3.6
    to check the detector condition.
2. Check whether the tip of the DFP Adjustable 
    Drive Shaft interrupts the detector.
3. Check the following connection and 
    soldering condition on each connector.
a. CN3002(DFP HOME SENSOR Board) to     
    CN2003 (USR RELAY Board)
b. CN2001 (USR RELAY Board) to CN1007 
       (CONTROL Board)
4. Check "DFP_HOME" signal.: 5 V (when the
     tip of the DFP Adjustable Drive Shaft
     interrupts IC3001 (DFP Home Sensor) on
     the DFP HOME SENSOR Board.)
         
 CN1007-2nd pin and IC0017-5th pin
5. Check the soldering condition of IC0017 on 
    the CONTROL Board and repair it.
6. Replace faulty parts or boards.
F60 (Front-side gain
adjustment error)
50
00
00
00 1. Scanning Glass (F) is dirty.
Clean the glass surface. (See 7.2.)
2. CIS (F) Unit does not work
    properly.
1. Check if the White Standard Sheet is not
    dirty and not peeled, then is stuck properly.
2. When the scanner starts after turning on it,
    the reference plates rotates and stops once
    while the green light blinks, then open the
    ADF door before they rotates again.
    Check if the White Standard Sheet on the 
    reference plates stop at the correct position
    referring to 8.4.5 reference Plate(F) and
    8.5.27 reference Plate(B).
3. Execute CIS Level test in Sec.9.3.6 to
    check the peak level.
4. Check that LED (F) lights during CIS Level
    test.
5. Check the following connections and
    soldering condition on each connector.
    a. CIS (F) Unit to CN2022(CIS (F) 
          RERAY Board)
    b. CN2023, CN2024(CIS (F) RERAY Board)
          to CN1003, CN1004 (CONTROL Board)
6. Check the power supply for LED.
      
 IC2017-5th pin: 3.3 V
      
 CN2024-1st pin: 3.9 V
7. Replace faulty parts or boards.
3. Pixel data from CIS (F) Unit or
    image processing circuit
     has some problems.
1. Check the following connections and
    soldering condition on each connector.
    a. CIS (F) Unit to CN2022 (CIS (F) RERAY
          Board)
    b. CN2023,CN2024 (CIS (F) RERAY Board)
          to CN1003,CN1004(CONTROL Board)
2. Check the following power supply to
    CONTROL Board.
    
 CN1004-1st pin (CONTROL Board): 3.9 V
3. Check the soldering condition of the
    CN1004,IC0030, and their surrounding 
    circuit on the CONTROL Board.
4. Replace faulty parts or boards.
Error Code
Possible Cause
Check Point
Remarks
Classified Code  ST1 ST2 ST3 ST4
130
F61 (Front-side
black level error)
51
00
00
00 1. Pixel data from Optical Unit
    Front or image processing
    circuit has some problems.
1.Check if the White Standard Sheet is not dirty
   and not peeled, then is stuck properly.
2.When the scanner starts after turning on it,
   the reference plates rotates and stops once
   while the green light blinks, then open the
   ADF door before they rotates again.
   Check if the White Standard Sheet on the 
   reference plates stop at the correct position
   referring to 8.4.5 reference Plate(F) and
   8.5.27 reference Plate(B).
3.Refer to the above 3rd item on the F60.
F62 (Back-side gain
adjustment error)
52
00
00
00 1. Scanning Glass (B) is dirty.
Clean the glass surface. (See 7.2.)
2. CIS (B) Unit does not work
    properly.
1.Check if the White Standard Sheet is not dirty
   and not peeled, then is stuck properly.
2.When the scanner starts after turning on it,
   the reference plates rotates and stops once
   while the green light blinks, then open the
   ADF door before they rotates again.
   Check if the White Standard Sheet on the 
   reference plates stop at the correct position
   referring to 8.4.5 reference Plate(F) and
   8.5.27 reference Plate(B).
3. Execute CIS Level test in Sec.9.3.6 to
    check the peak level.
4. Check that LED (B) lights during CIS Level
    test.
5. Check the following connections and
    soldering condition on each connector.
    a. CIS (B) Unit to CN2025 (CIS (B) RERAY
         Board)
    b. CN2026,CN2027(CIS(B) RERAY Board)
          to CN1005,CN1006(CONTROL Board)
6. Check the power supply for LED.
      
 IC2016-5th pin: 3.3 V
      
 CN2024-1st pin: 3.9 V
7. Replace faulty parts or boards.
3. Pixel data from Optical Unit Back 
   or image processing circuit
   has some problems.
1. Check the following connections and
    soldering condition on each connector.
     a. CIS (B) Unit to CN2025 (CIS (B) RERAY
          Board)
     b. CN2026, CN2027 (CIS (B) RERAY Board)
          to CN1005, CN1006 (CONTROL Board)
2. Check the following power supply to
    CONTROL Board.
    
 CN1006-1st pin (CONTROL Board): 3.9 V
3. Check the soldering condition of the
    CN1005, CN1006, IC0031, and their
     surrounding circuit on the CONTROL Board.
4. Replace faulty parts or boards.
F63 (Back-side
black level error)
53
00
00
00 1. Pixel data from Optical Unit Back
    or image processing circuit
    has some problems.
1.Check if the White Standard Sheet is not dirty
   and not peeled, then is stuck properly.
2.When the scanner starts after turning on it,
   the reference plates rotates and stops once
   while the green light blinks, then open the
   ADF door before they rotates again.
   Check if the White Standard Sheet on the 
   reference plates stop at the correct position
   referring to 8.4.5 reference Plate(F) and
   8.5.27 reference Plate(B).
3.Refer to the above 3rd item on the F62.
F80 (Double Feed
Detector
adjustment error)
60
00
00
00 1. Double Feed Detector (G) does
not work, properly.
Refer to the 5th item on Classified Code U23.
2. Double Feed Detector (R) does
not work, properly.
Refer to the 6th item on Classified Code U23.
Error Code
Possible Cause
Check Point
Remarks
Classified Code  ST1 ST2 ST3 ST4
Page of 127
Display

Panasonic KV-S5076H / KV-S5046H Service Manual ▷ Download