DOWNLOAD Panasonic KV-S4065CL / KV-S4065CW / KV-S4065CWCN / KV-S4085CL / KV-S4085CW / KV-S4085CWCN (serv.man2) Service Manual ↓ Size: 5.57 MB | Pages: 36 in PDF or view online for FREE

Model
KV-S4065CL KV-S4065CW KV-S4065CWCN KV-S4085CL KV-S4085CW KV-S4085CWCN (serv.man2)
Pages
36
Size
5.57 MB
Type
PDF
Document
Service Manual / Supplement
Brand
Device
Service Manual / Other / HIGH SPEED COLOR SCANNER
File
kv-s4065cl-kv-s4065cw-kv-s4065cwcn-kv-s4085cl-kv-s.pdf
Date

Panasonic KV-S4065CL / KV-S4065CW / KV-S4065CWCN / KV-S4085CL / KV-S4085CW / KV-S4085CWCN (serv.man2) Service Manual / Supplement ▷ View online

5
2.1.2.
"Section 8.2.3 Post-imprinter Door (Imprinter Cover)"
(1) Open the Post-imprinter Door.
(2) In the direction of the arrow, pull the right tip of the
    Post-imprinter Door along the groove.
    Then pull the left tip of the Post-imprinter Door
   backward to remove the door.  
6
2.2.
"Section 8.4 Board Assembly"
2.2.1.
"Section 8.4.1 CONTROL Board and DRIVE Board"
(1) Remove the Right Cover. (See 8.2.1.)
(2) Remove the screw (a), screw (b), and 2 screws (c) from the
      back.
(3) Remove the screw from the right.
(4) Release the connector wires from the 3 wire clamps.
   
(5) Pull out the Board Plate Assembly after releasing the
     connector wires from the 5 wire clamps.   
    Reassembling Note:
 Make sure to fasten the cables with the clamper
 so that the bundle of single-wire is located on the
 multi-wire cables (Shield cable and gray color
 cable).
7
3 “SECTION 9 SERVICE UTILITY & SELF TEST”
3.1.
“Section 9.3 Operation”
3.1.1.
“Section 9.3.1 Scanner Status” 
8
3.1.2.
“Section 9.3.7 Adjustment”
Item
Operation
Default
Remarks
Shading
1. Click “Shading” on the main menu.
2. Confirm the message “The data of User Shading will be
    also overwritten”
 on the display.
    And if the message is acceptable, click “OK”.
     Note:
  This procedure is avaiable only after executing User
  Shading. 
3. Clean the conveyor, rollers, and Image Sensor Cover
     according to the message on the display.
    And click “OK”.
4. Switch Reference Plates to white according to the message
    on the display.
    And click “OK”.
5. Set the accessory Shading Paper or Shading Paper
   (Part No.: See 14.6.) on the Hopper Tray in landscape
    orientation.
6. And click “OK” to scan the Shading Paper.
7. Switch the Reference Plates to black according to the
    message on the display.
8. Click “OK” to return to the main menu.
Until this process is
completed, don’t stop the
process by opening any
doors or turning off the
scanner. 
All Position
1. Set 2 pcs of test chart A (Part No.: See 14.6.) on the Hopper
    Tray in portrait orientation.
2. Click “All position” on the main menu to execute scanning
    position and length adjustment. 
3. Check the result.
4. Click “OK” to return to the main menu.
Set 2 pcs of test chart A in
order.
 1st page: Front side
 2nd page: Back side
Individual Position 1. Adjust Automatically.
    a. Set test chart A (Part No.: See 14.6.) on the Hopper Tray.
    b. Click “Individual Position” on the main menu.
    c. Click one of 5 “Adjust Automatically” buttons on the
        “Individual Position” dialog box to execute the
        adjustment.
    d. Check the result.
    e. Click “OK” to finish the adjustment.
     f. Click “OK” to return to the main menu.
2. Adjust Manually.
    a. Click “Individual Position” on the main menu.
    b. Change the parameter (mm, %) on the “Individual
        Position”
 dialog box as required. (Refer to Remarks.)
    c. Click “OK” to renew the setting, and to return to the
        main menu.  
1. Adjust Automatically
   5 automatic adjustment
     a. Adjust Length
     b. Adjust Front V. Position
     c. Adjust Front H. Position
     d. Adjust Back V. Position
     e. Adjust Back H. Position
 
2. Adjust Manually
   (Length)
    +: Increasing the number
        makes the scanning
        document length
        
shorter.
  (Vertical Position)
     +: Increasing the number
         makes the document
         scanning position shifted
         
upward.
(Horizontal Position)
     +: Increasing the number
         makes the document
         scanning position shifted
         to the 
left
.
Note
If the appropriate
scanning position can
not be obtained by any
of the manual
adjustments, check CIS
installation.
Page of 36
Display

Click on the first or last page to see other KV-S4065CL / KV-S4065CW / KV-S4065CWCN / KV-S4085CL / KV-S4085CW / KV-S4085CWCN (serv.man2) service manuals if exist.