37
8.2.11. DOOR DETECTION Board 
8.2.12. STARTING SENSOR Board 
(5) Remove the CONTROL Board's Box from the unit.
(1) Remove the CONTROL Board's Box. (See 8.2.10.)
(2) Unlock the claw to release the DOOR DETECTION Board 
from the unit.
(3) Disconnect the connector to the DOOR DETECTION Board.
(1) Remove the CONTROL Board’s Box. (See 8.2.10.)
(2) Unlock the claw to release the STARTING SENSOR Board
from the unit.
(3) Disconnect the connector to the STARTING SENSOR Board.
38
8.2.13. ULTRASONIC SENSOR (R) Board 
8.2.14. CIS (F) 
(1) Remove the CONTROL Board's Box. (See 8.2.10.)
(2) Remove the screw (b) that secures the ULTRASONIC
SENSOR (R) Board.
(3) Disconnect the connector to the ULTRASONIC SENSOR (R)
Board.
(1) Remove the CONTROL Board’s Box. (See 8.2.10.)
(2) Remove the 2 screws (b) that secure the CIS Cover.
(3) Unlock the 2 claws to release CIS (F) (with the CIS Cover)
from the unit.
(4) Disconnect the flat-cable to the CIS (F).
(5) Remove the CIS (F) from the CIS Cover.
39
8.2.15. Side-plate Assembly 
8.2.16. Conveyor Motor
(1) Remove the Front Cover. (See 8.2.5.)
(2) Remove the 2 screws (b) and screw (a) that secure the
Side-plate Assembly.
 Reassembling Note:
Make sure to position the Idle-pulley of the Side-plate
Assembly outside of the Conveyor Belt 2.
(1) Remove the Side-plate Assembly. (See 8.2.15.)
(2) Remove the Bottom Plate. (See 8.2.7.)
(3) Remove the 2 screws (a) that secure the Conveyor Motor.
(4) Release the Conveyor Motor from the Conveyor Belt 1.
(5) Disconnect the connector to the Conveyor Motor.
40
8.2.17. Conveyor Roller
(1) Remove the Side-plate Assembly. (See 8.2.15.)
(2) Remove the Conveyor Belt 2.
(3) Pull and remove the Pulley of the Conveyor Roller in the
direction of the arrow, while releasing the stopper on the
pulley.
Note:
After reassembling the Pulley, be sure to check that the
Pulley is locked to the Conveyor Roller by pulling the
pulley.
(4) Slide and remove the bearing from the Conveyor Roller in the 
direction of the arrow.
Page of 127