Panasonic KV-S1026C / KV-S1015C (serv.man2) Service Manual ▷ View online
29
(6) Close the Double-feed Prevention Roller Cover.
Note:
Make sure to close the Double-feed Prevention Roller
Cover tightly until it clicks into place.
Cover tightly until it clicks into place.
(7) Close the ADF Door slowly until it clicks into place.
(8) Plug the AC Adaptor into the scanner, and then push the
Power Button to turn on the scanner.
(9) After replacing the Paper Feed Roller and Double-feed
Prevention Roller, execute “Clear Counter” for replacing roller
with Service Utility. (See 9.3.4.)
with Service Utility. (See 9.3.4.)
30
8 DISASSEMBLY INSTRUCTIONS
8.1.
Disassembly Flowchart
This flowchart indicates the disassembly sequence for the Exterior, Mechanical parts, Unit Components, and Circuit Board
assemblies.
When reassembling, perform the steps in the reverse order unless otherwise instructed in Reassembling Notes.
assemblies.
When reassembling, perform the steps in the reverse order unless otherwise instructed in Reassembling Notes.
Note:
Disassembly flowchart explanation
* This sample flowchart shows that, to disassemble C, the procedures 1 and 2 must be performed first before
proceeding to the procedure 3.
proceeding to the procedure 3.
31
32
Note:
Before disassembling any of the above parts, perform the following steps.
(1) Unplug AC Adaptor from the scanner. (See 7.2.1.)
(2) Pull and remove the Feed Tray while distorting the both sides of the tray in the direction of the arrows (1).
Before disassembling any of the above parts, perform the following steps.
(1) Unplug AC Adaptor from the scanner. (See 7.2.1.)
(2) Pull and remove the Feed Tray while distorting the both sides of the tray in the direction of the arrows (1).
(3) Remove the Mixed Batch Card Guide.
Click on the first or last page to see other KV-S1026C / KV-S1015C (serv.man2) service manuals if exist.