Panasonic KV-S1026C / KV-S1015C (serv.man2) Service Manual ▷ View online
21
7 MAINTENANCE
7.1.
Maintenance Chart
C: Clean each of the following parts every 2,000 sheets scanned.
R: Replace rollers (Paper Feed, Double-feed Prevention) every 100,000 sheets scanned.
(x 1000 sheets)
R: Replace rollers (Paper Feed, Double-feed Prevention) every 100,000 sheets scanned.
(x 1000 sheets)
Note:
1. The above roller maintenance values are stored in the maintenance counter (Refer to Sec. 9), and the PC
will notify users of cleaning and replacement timing if the utility software for the scanner has been installed.
2. The maintenance schedule was determined according to paper standards (A4: 80 g/m
will notify users of cleaning and replacement timing if the utility software for the scanner has been installed.
2. The maintenance schedule was determined according to paper standards (A4: 80 g/m
2
/ Letter: 20 lb.),
which can vary greatly between users. Therefore, the schedule may vary depending on usage conditions.
Maintenance Parts
Reference Section
2
4
6
8 to 40
60
70
80
90 100
Paper Feed Roller
Sec. 14.3
C
C
C Clean each part every
2 (x 1000) sheets
scanned.
scanned.
C
C
C
C
R
Double-feed Prevention Roller
Sec. 14.2
C
C
C
C
C
C
C
R
Conveyor Roller
Sec. 14.3
C
C
C
C
C
C
C
C
Exit Roller
Sec. 14.3
C
C
C
C
C
C
C
C
Free Rollers
Sec. 14.2
C
C
C
C
C
C
C
C
Scanning Glass (F)*
Sec. 14.3
C
C
C
C
C
C
C
C
Scanning Glass (B)*
Sec. 14.2
C
C
C
C
C
C
C
C
Double Feed Detector (Generator) Sec. 14.2
C
C
C
C
C
C
C
C
Double Feed Detector (Receive)
Sec. 14.3
C
C
C
C
C
C
C
C
22
7.2.
Cleaning
7.2.1.
Preparation
Before cleaning, the following procedures are required.
(1) Push and hold the Power Button for one second or more to
turn off the scanner.
Then, unplug the AC Adaptor from the scanner.
turn off the scanner.
Then, unplug the AC Adaptor from the scanner.
(2) Push the Door Open Button to open the ADF Door.
Note:
When the ADF Door does not open even if the Door Open
Button is pushed repeatedly, there is a possibility that the
door was not closed properly.
In this case, try to close the ADF Door until it clicks into
place.
When the ADF Door does not open even if the Door Open
Button is pushed repeatedly, there is a possibility that the
door was not closed properly.
In this case, try to close the ADF Door until it clicks into
place.
23
7.2.2.
Cleaning
According to the instructions in the following figures (Fig. 7.2.2-1 and Fig. 7.2.2-2), wipe off the dirt from the surface of each part to
maintain the performance of the scanner.
maintain the performance of the scanner.
(Fig. 7.2.2-1): Cleaning Parts and Action
Note:
*
(1) Open the bag on the dotted line and take out the Roller Cleaning Paper.
(2) If the bag is left open for a long period of time before using it, the alcohol will evaporate.
Please use the Roller Cleaning Paper immediately after opening the bag.
(3) Keep the roller cleaning paper out of reach of small children.
(4) Do not store the Roller Cleaning Paper in direct sunlight or in a place with temperature over 40
(4) Do not store the Roller Cleaning Paper in direct sunlight or in a place with temperature over 40
°C (104°F).
(5) The Roller Cleaning Paper (Model No. KV-SS03) is available from your sales representative.
Maintenance Parts
Action Code
Action
Remarks
1 Paper Feed Roller
C1
Clean each surface with
*
Roller
Cleaning Paper (Model No.
KV-SS03).
KV-SS03).
After cleaning the Paper Feed and
Double-feed Prevention Rollers,
execute “Clear Counter” for
cleaning roller with Service Utility.
(See 9.3.)
Double-feed Prevention Rollers,
execute “Clear Counter” for
cleaning roller with Service Utility.
(See 9.3.)
2 Double-feed Prevention Roller
C1
3 Conveyor Roller
C1
4 Exit Roller
C1
5 Free Rollers
C1
6 Scanning Glass (F)
C2
Clean each scanning glass with a
soft and dry cloth.
soft and dry cloth.
7 Scanning Glass (B)
C2
8 Double Feed Detector (Generator)
S
Sweep the dirt off the detector with a
cotton swab.
cotton swab.
9 Double Feed Detector (Receive)
S
24
(Fig.7.2.2-2) Cleaning Position
Click on the first or last page to see other KV-S1026C / KV-S1015C (serv.man2) service manuals if exist.