DOWNLOAD Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H Service Manual ↓ Size: 3.2 MB | Pages: 64 in PDF or view online for FREE

Model
SDR-H80P SDR-H80PC SDR-H80EG SDR-H80EE SDR-H80EB SDR-H80EP SDR-H80EF SDR-H80EC SDR-H80GC SDR-H80GN SDR-H80GJ SDR-H80GK SDR-H80PU SDR-H80PR SDR-H81EE SDR-H81EB SDR-H90P SDR-H90PC SDR-H90EG SDR-H90EE SDR-H90EB SDR-H
Pages
64
Size
3.2 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SD CARD / HARD DISK VIDEO CAMERA
File
sdr-h80p-sdr-h80pc-sdr-h80eg-sdr-h80ee-sdr-h80eb-s.pdf
Date

Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H Service Manual ▷ View online

 1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
 2. Connect “A” to exposed metallic part on the set. And
connect “B” to a good earth ground, as shown in .
 3. Use an AC voltmeter, with 1 k
W/V or more sensitivity, to
measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the
voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
 6. The potential at any point should not exceed 0.25 V RMS.
A leakage current tester (Simpson Model 229 or equivalent)
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
Figure 1
1 Safety Precaution
1.1. General Guidelines
 1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the
Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent X-RADIATION, shock fire, or other hazards. Do not modify
the original design without permission of manufacturer.
 2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC
power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury
from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during
servicing.
 3. When servicing, observe the original lead dress. It a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
 4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
 5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
 1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
 2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
W and 5.2MW. When the exposed metal does not have a return path to the chassis,
the reading must be infinity.
1.1.2. Leakage current hot check (See Figure 1)
3
SDR-H80P
2 Warning
2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatic Sensitive
(ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatic Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electrostatic discharge (ESD).
 1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
 2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
 4. Use only an antistatic solder removal device. Some solder removal devices not classified as “antistatic (ESD protected)” can
generate electrical charge sufficient to damage ES devices.
 5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
CAUTION:
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
 8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD)
sufficient to damage an ES device).
4
SDR-H80P
2.2. Service caution based on legal restrictions
2.2.1. General description about Lead Free Solder (PbF)
The lead free solder has been used in the mounting process of all electrical components on the printed circuit boards used for this
equipment in considering the globally environmental conservation.
The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists of tin
(Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30 degrees C (86°F) more than that
of the normal solder.
Definition of PCB Lead Free Solder being used
The letter of “PbF” is printed either foil side or components side on the PCB using the lead free solder.
(See right figure)
Service caution for repair work using Lead Free Solder (PbF)
     ·    The lead free solder has to be used when repairing the equipment for which the lead free solder is used.
(Definition: The letter of “PbF” is printed on the PCB using the lead free solder.)
     ·    To put lead free solder, it should be well molten and mixed with the original lead free solder.
     ·    Remove the remaining lead free solder on the PCB cleanly for soldering of the new IC.
     ·    Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt
the lead free solder.
     ·    Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30
degrees C (662±86°F).
Recommended Lead Free Solder (Service Parts Route.)
     ·    The following 3 types of lead free solder are available through the service parts route.
RFKZ03D01KS-----------(0.3mm 100g Reel)
RFKZ06D01KS-----------(0.6mm 100g Reel)
RFKZ10D01KS-----------(1.0mm 100g Reel)
Note
* Ingredient: tin (Sn), 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%
5
SDR-H80P
2.3. Caution for AC Cord
(For EB/GC)
2.3.1. Information for your safety
IMPORTANT
Your attention is drawn to the fact that recording of pre-
recorded tapes or discs or other published or broadcast
material may infringe copyright laws.
WARNING
To reduce the risk of fire or shock hazard, do not expose
this equipment to rain or moisture.
CAUTION
To reduce the risk of fire or shock hazard and annoying
interference, use the recommended accessories only.
FOR YOUR SAFETY
DO NOT REMOVE THE OUTER COVER
To prevent electric shock, do not remove the cover. No user
serviceable parts inside. Refer servicing to qualified service
personnel.
2.3.2. Caution for AC mains lead
For your safety, please read the following text carefully.
This appliance is supplied with a moulded three-pin mains plug
for your safety and convenience.
A 5-ampere fuse is fitted in this plug.
Should the fuse need to be replaced please ensure that the
replacement fuse has a rating of 5 amperes and it is approved
by ASTA or BSI to BS1362
Check for the ASRA mark or the BSI mark on the body of the
fuse.
If the plug contains a removable fuse cover you must ensure
that it is refitted when the fuse is replaced.
If you lose the fuse cover, the plug must not be used until a
replacement cover is obtained.
A replacement fuse cover can be purchased from your local
Panasonic Dealer.
If the fitted moulded plug is unsuitable for the socket outlet in
your home then the fuse should be removed and the plug cut
off and disposed of safety.
There is a danger of severe electrical shock if the cut off plug
is inserted into any 13-ampere socket.
If a new plug is to be fitted please observe the wiring code as
shown below.
If in any doubt, please consult a qualified electrician.
2.3.2.1. Important
The wires in this mains lead are coloured in accordance with
the following code:
Blue
Neutral
Brown
Live
As the colours of the wires in the mains lead of this appliance
may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured BLUE must be connected to the
terminal in the plug which is marked with the letter N or
coloured BLACK.
The wire which is coloured BROWN must be connected to the
terminal in the plug which is marked with the letter L or coloured
RED.
Under no circumstances should either of these wires be
connected to the earth terminal of the three pin plug, marked
with the letter E or the Earth Symbol.
2.3.2.2. Before use
remove the Connector Cover as follows.
2.3.2.3. How to replace the Fuse
 1. Remove the Fuse Cover with a screwdriver.
 2. Replace the fuse and attach the Fuse cover.
6
SDR-H80P
Page of 64
Display

Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H Service Manual ▷ Download

  • DOWNLOAD Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H Service Manual ↓ Size: 3.2 MB | Pages: 64 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H Movie. Information contained in Panasonic SDR-H80P / SDR-H80PC / SDR-H80EG / SDR-H80EE / SDR-H80EB / SDR-H80EP / SDR-H80EF / SDR-H80EC / SDR-H80GC / SDR-H80GN / SDR-H80GJ / SDR-H80GK / SDR-H80PU / SDR-H80PR / SDR-H81EE / SDR-H81EB / SDR-H90P / SDR-H90PC / SDR-H90EG / SDR-H90EE / SDR-H90EB / SDR-H Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.