7 TROUBLESHOOTING GUIDE
DANGER: HIGH VOLTAGES
1. DO NOT RE-ADJUST PRESET CONTROL on the H.V.Inverter (U). It is very dangerous to repair or adjust without proper test equipment
because this circuit generates very large current and high voltage. Operating a misaligned inverter circuit is dangerous.
2. Ensure proper grounding before troubleshooting.
3. Be careful of the high voltage circuitry, taking necessary precautions when troubleshooting.
4. Discharge high voltage remaining in the H.V.Inverter (U).
5. When checking the continuity of the switches or the H.V.Inverter, disconnect one lead wire from these parts and then check continuity with the
AC plug removed. Doing otherwise may result in a false reading or damage to your meter. When disconnecting a plastic connector from a
terminal, you must hold the plastic connector instead of the lead wire and then disconnect it, otherwise lead wire may be damaged or the
connector cannot be removed.
6. Do not touch any parts of the circuitry on the digital programmer circuit, since static electric discharge may damage this control panel. Always
touch ground while working on this panel to discharge any static charge in your body.
7. 220V AC is present on the digital programmer circuit (Terminals of power relay’s and primary circuit of Digital Programmer Circuit). When
troubleshooting, be cautious of possible electrical shock hazard.
Before troubleshooting, operate the microwave oven following the correct operating procedures in the instruction manual in order
to find the exact cause of any trouble, since operator error may be mistaken for the oven’s malfunction.
7.1. (Troubleshooting) Oven stops operation during cooking
SYMPTOM
CAUSE
CORRECTIONS
1. Oven stops in 3 seconds after
pressing [Start] pad
No 230-240V AC is supplied to H.V.Inverter (U)
CN702 terminals
1. Latch Switch
2. Power relay RL1
3. Loose lead wire connector CN701, CN702
4. H.V. Inverter (U)
Oven stops in 23 seconds after
pressing [Start] pad
H.V.Inverter (U) operates by the control signals
from DPC but magnetron is not oscillating
1. Magnetron
2. Loose lead wire connector CN703
2. No display and no operation at all.
Fuse is blown.
Most probably loose connection of connectors, or
door latch mechanism is not adjusted properly
1. Align door, Door Latch Switches
2. Loose wiring connectors
17
NN-SD38HS / NN-SD36HB
SYMPTOM
CAUSE
CORRECTIONS
1. Oven is dead.
1. Open or loose lead wire harness
Fuse is OK.
2. Open thermal cutout / thermistor
Check thermal cutout is defective.
No display and no operation at all.
3. Open low voltage transformer
4. Defective DPC
2. No display and no operation at all.
Fuse is blown.
1. Shorted lead wire harness
Check adjustment of primary, secondary latch
switch and monitor interlock switch including
door.
2. Defective primary latch switch (NOTE 1)
3. Defective monitor interlock switch (NOTE 1)
4. Defective Inverter Power Supply (U)
NOTE 1:
All of these switches must be replaced at the same time.
Check continuity of power relay RL1 contacts (between 1 and 2) and if it has continuity, replace
power relay RL1 also.
3. Oven does not accept key input
(Program)
1. Key input is not in proper sequence
Refer to operation procedure.
2. Open or loose connection of membrane switch
to DPC (Flat cable)
3. Shorted or open membrane key board
4. Defective DPC
Refer to DPC troubleshooting.
4. Timer starts count down but no
microwave oscillation.
(No heat while oven lamp and fan
motor turn on)
1. Off-alignment of primary latch switch
Adjust door and latch switches.
2. Open or loose connection of high voltage
circuit especially magnetron filament circuit
NOTE:
Large contact resistance will cause lower
magnetron filament voltage and cause
magnetron to have lower output and/or be
intermittent.
3. Defective high voltage component
H.V. Inverter Power Supply (U)
Magnetron
Check high voltage component according to
component test procedure and replace if it is
defective.
4. Open or loose wiring of power relay RL1
5. Defective primary latch switch
6. Defective DPC or power relay RL1
Refer to DPC troubleshooting
5. Oven can program but timer does not
start countdown.
1. Open or loose wiring of secondary latch switch
2. Off-alignment of secondary latch switch
3. Defective secondary latch switch
6. Microwave output is low. Oven takes
longer time to cook food.
1. Decrease in power source voltage
Consult electrician
2. Open or loose wiring of magnetron filament
circuit.(Intermittent oscillation)
3. Aging change of magnetron
7. Fan motor turns on and turntable
motor rotates when door is opened.
1. Low voltage transformer on DPC.
8. Oven does not operate and return to
plugged in mode as soon as [Start]
pad is pressed.
1. Defective DPC
Check grounding connector on escutcheon
base.
9. Loud buzzing noise can be heard.
1. Loose fan and fan motor
10. Turntable motor does not rotate.
1. Open or loose wiring of turntable motor
2. Defective turntable motor
11. Oven stops operation during cooking.
1. Open or loose wiring of primary and
secondary latch switch
Adjust door and latch switches.
2. Operation of thermal cutout
18
NN-SD38HS / NN-SD36HB
7.2. Troubleshooting of inverter circuit (U) and magnetron
This oven is programmed with a self diagnostics failure code system which will help for troubleshooting. H95, H97, H98 and H99
are the provided failure codes to indicate magnetron and inverter circuit problem areas. This section explains failure codes of H95,
H97, H98 and H99. First, you must program the DPC into TEST MODE, press Timer/Clock pad twice
→ Press Start pad once
→ press Micro Power pad once. Program unit for operation. H95, H97, H98, H99 appears in display window a short time after
[Start] pad is pressed and there is no microwave oscillation.
Alternate way to troubleshoot oven with AC Ampere meter used
H95, H97, H98, H99 appears in display window a short time after [Start] pad is pressed and no microwave oscillation with AC
Ampere meter used for troubleshooting.
19
NN-SD38HS / NN-SD36HB
7.3. Trouble related to Digital Programmer Circuit
SYMPTOM
STEP
CHECK
RESULT
CAUSE/CORRECTIONS
No display when oven is first plugged
in
1
Fuse pattern of D.P.C.
Normal
→Step2
Open
Replace D.P.C. or Fuse
Pattern
2
Low voltage transforment (L.V.T.)
secondary voltage
Abnormal 0V
L.V.T.
Normal
→Step3
3
IC10 pin5 voltage
Abnormal
IC10, ZD10
Normal=5V
IC1, CX320, Display
No key input
1
Membrane switch continuity
Abnormal
Membrane switch
Normal
IC1
No beep sound
1
IC1 pin 62 voltage
Abnormal
IC1
Normal=5V
BZ210, Q210
No microwave oscillation at any power
1
IC1 pin 27 voltages while operation at high
power
Abnormal
IC1
Normal=5V
→Step2
2
Collector of Q220 voltage
Abnormal
Q220 and /or Q222, Q225,
Q227
Normal 0.7V
→Step3
3
Short circuit between collector and emitter
of Q220
Still not turn on
RL1
RL1 turns on
Q220 and /or Q222, Q225,
Q227
Dark or unclear display
1
Replace display and check operation
Normal
Display
Abnormal
IC1
Missing or lighting of unnecessary
segment
1
Replace IC1 and check operation
Normal
IC1
Abnormal
Display
H95/H97/H98 appears in window and
oven stops operation.Program High
power for 1 minute and conduct
following test quickly, unless
H95/H97/H98 appears and oven stops
1
Unplug CN702 (2 pin) connector and
measure voltage between terminals
Abnormal=0V
1. Latch Switch
2. D.P.C. /Power Relay
Normal=220V
→Step2
2
Unplug CN701 (3 pin) connector and
measure pin3 voltage
Abnormal=0V
D.P.C.
Approx. AC 3V
Magnetron
20
NN-SD38HS / NN-SD36HB
Page of 31
Display