1 SCHEMATIC DIAGRAM (NN-S453WF & NN-S553WF)
5
NN-S453WF
2 SCHEMATIC DIAGRAM (NN-K593MF/K573/K543WF)
6
NN-S453WF
3.1. Variable power cooking
control
High Voltage Inverter Power supply (U) controls output power
by the signal from Digital Programmer Circuit (DPC). Power
relay stays ON for P3 to P10 and For P1 to P2, both inverter
drive signal and power relay to control output power.
NOTE:
The ON/OFF time ratio does not correspond with the
percentage of microwave power since approximately 2
seconds
are
required
for
heating
of
magnetron
filament.
Variable Power Cooking
POWER SETTING
OUTPUT
POWER(%)
APPROX.
ON-OFF TIME OF
POWER RELAY (RY1)
ON(SEC)
OFF(SEC)
HIGH
P10
100%
22
0
P9
90%
22
0
P8
80%
22
0
MEDIUM-HIGH
P7
70%
22
0
MEDIUM
P6
60%
22
0
P5
50%
22
0
P4
40%
22
0
MEDIUM-LOW
P3
30%
22
0
P2
20%
15
7
LOW
P1
10%
8
14
DEFROST
P3
30%
22
0
3.2. Inverter power supply circuit
NEW H.V.
This Inverter Power Supply Circuit supplies 4,000V DC to the
magnetron tube from the line voltage, 220-240V 50Hz/60Hz AC
input. functions as the H.V. transformer, the H.V.capacitor and
H.V.diode.
 1. The AC input voltage 220-240V 50Hz/60Hz is rectified to
DC voltage immediately.
 2. DC voltage will be supplied to the switching devices called
IGBT. These devices will be switched ON-OFF by the 20 to
40 KHz PWM(pulse width modulation) signal from the
microcomputer in the DPC.
 3. This drives the High voltage transformer to increase up to
2,000V AC and approximately 3V AC by means of
transformer.
 4. Then
the
half-wave
doubler
voltage
rectifier
circuit,
consisting of the H.V. diodes and Capacitors, generates the
necessary 4,000V DC needed for the magnetron.
 5. Output power of the magnetron tube is always monitored by
the signal output from the current transformer built into the
inverter circuit.
 6. Then this signal will be fed back to the microcomputer in the
DPC
to
determine
operating
conditions
and
output
necessary to control PWM signal to the Inverter Power
Supply to control output power.
3.3. Inverter turbo defrost
When this Auto Control feature is selected and the Start Pad is
tapped:
 1. The digital programer circuit determines the power level and
cooking time to complete cooking and indicates the
operating state in the display window. Table shows the
corresponding cooking times for respective serving by
categories.
 2. When cooking time the display window has elapsed, the
oven turns off automatically by a control signal from the
digital programmer circuit.
3 DESCRIPTION OF OPERATING SEQUENCE
7
NN-S453WF
Unlike many other appliances, the microwave oven is a high
voltage, high current device. It is free from danger in ordinary
use, though extreme care should be taken during repair.
Caution
Servicemen
should
remove
their
watches
whenever
working close to or replacing the magnetron.
4.1. Check the grounding
Do not operate on a two wire extension cord. The microwave
oven is designed to be grounded when used. It is imperative,
therefore, to ensure the appliance is properly grounded before
beginning repair work.
4.2. Inverter warnings
DANGER, HIGH VOLTAGE AND HIGH TEMPERATURE
(HOT/LINE) OF THE INVERTER POWER SUPPLY (U)
This high voltage inverter power supply handles very high
voltage and current for the magnetron tube. Though it is
free from danger in ordinary use, extreme care should be
taken during repair.
The aluminum heat sink is also energized with high voltage
(HOT), so do not touch when the AC input terminals are
energized.
The
power
devices
Collector
is
directly
connected to the aluminum heat sink.
The aluminum heat sink may be HOT due to heat energy,
therefore, extreme care should be taken during servicing.
H.V. Inverter warning
WARNING
FOR
INVERTER
POWER
SUPPLY
(U)
GROUNDING
Check the high voltage inverter power supply circuit
grounding. The high voltage inverter power supply circuit
board must have a proper chassis ground, the inverter
grounding bracket must be connected to the chassis. If the
inverter board is not grounded it will expose the user to very
high voltages and cause extreme DANGER! Be sure that
the inverter circuit is properly grounded via the inverter
earth bracket.
Grounding of the inverter circuit board
WARNING!
DISCHARGE
THE
HIGH
VOLATGE
CAPACITORS
For about 30 seconds after the oven is turned off, an
electric charge remains in the high voltage capacitors in the
inverter power supply circuit board.
When replacing or checking parts, remove the power plug
from the outlet and short the inverter output terminal of the
magnetron filament terminals to the chassis ground with an
insulated handle screwdriver to discharge. Please be sure
to touch the chassis ground side first and then short to the
output terminals.
Discharging the high voltage capacitors
WARNING
There is high voltage present with high current capabilities
in the circuits of the primary and secondary windings, choke
coil and heat sink of the inverter. It is extremely dangerous
to work on or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit
including the filament voltage of the magnetron.
WARNING
Never touch any circuit wiring with your hand or with an
insulated tool during operation.
4 CAUTIONS TO BE OBSERVED WHEN
TROUBLESHOOTING
8
NN-S453WF
Page of 37
Display

Click on the first or last page to see other NN-S453WF / NN-S553WF / NN-K593MF / NN-K573MF / NN-K573WF / NN-K543WF service manuals if exist.